The compact and handy Fluke laser distance meters were designed for indoor and limited outdoor applications. All three models are simple to operate,
with the Fluke durability and quality you expect. And, with specific function buttons, different tasks can be completed quickly and easily.
with the Fluke durability and quality you expect. And, with specific function buttons, different tasks can be completed quickly and easily.
The extra bright laser is clearly visible so you can always see your targeting point even if the target object is in a hard-to-reach spot, or a long distance
away. These units have a large LCD screen and buttons positioned for one-handed measurements.
away. These units have a large LCD screen and buttons positioned for one-handed measurements.
Distance Measurement | |
Typical measuring tolerance 1 | ±1.0 mm 3 |
Maximum measuring tolerance 2 | ±2.0 mm 3 |
Range at Leica Target Plate GZM26 | 80 m / 260 ft |
Typical range 1 | 80 m / 260 ft |
Range at unfavorable condition 4 | 60 m / 195 ft |
Smallest unit displayed | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Ø Laser point at distances | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Tilt measurement | |
Measuring tolerance to laser beam 5 | No |
Measuring tolerance to housing 5 | No |
Range | No |
General | |
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Protection class | IP54 |
Automatic laser off | After 90 seconds |
Automatic power off | After 180 seconds |
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | Up to 5,000 measurements |
Size (L x W x D) | 127 x 56 x 33 mm |
Weight (with batteries) | 153 g |
Temperature range Storage operation | -25°C to +70°C (-13°F to +158°F) |
-10°C to +50°C (14°F to +122°F) | |
Calibration cycle | Not applicable |
Maximum altitude | 3000 m |
Maximum relative humidity | 85% at 20°F to 120°F (-7°C to 50°C) |
Safety | IEC Standard No. 61010-1:2001 |
EN60825-1:2007 (Class II) | |
EMC | EN 55022:2010 |
EN 61000-4-3:2010 | |
EN 61000-4-8:2010 | |
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C. 2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C. 3.Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. 4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux. 5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°. |