Fluke’s 414D/62 MAX + Laser Distance Meter/ Infrared Thermometer Combo Kit is equipped for configuring layouts and troubleshooting electrical/HVAC issues rapidly. The IR thermometer is ideal for testing for overheating in electrical devices or HVAC components, while the laser distance meter verifies area, distance and volume for space configuration.
Fluke 414D Laser Distance Meter
Distance Measurement | |
Typical Measuring Tolerance (1) | ±2.0 mm (3) |
Maximum Measuring Tolerance (2) | ±3.0 mm (3) |
Range At Leica Target Plate GZM26 | 50 m / 165 ft |
Typical Range (1) | 40 m / 130 ft |
Range At Unfavorable Condition (4) | 35 m / 115 ft |
Smallest Unit Displayed | 1 mm / 1/16 in |
Ø Laser Point At Distances | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Tilt Measurement | |
Measuring Tolerance To Laser Beam (5) | No |
Measuring Tolerance To Housing (5) | No |
Range | No |
General | |
Laser Class | 2 |
Laser Type | 635 nm, < 1 mW |
Protection Class | IP40 |
Automatic Laser Off | After 90 seconds |
Automatic Power Off | After 180 seconds |
Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | Up to 3,000 measurements |
Size (L x W x D) | 116 x 53 x 33 mm |
Weight (with batteries) | 113 g |
Temperature Range: Storage Operation | -25°C to +70°C (-13°F to +158°F) |
0°C to +40°C (32°F to +104°F) | |
Calibration Cycle | Not applicable |
Maximum Altitude | 3000 m |
Maximum Relative Humidity | 85% at 20°F to 120°F (-7°C to 50°C) |
Safety | IEC Standard No. 61010-1:2001 |
EN60825-1:2007 (Class II) | |
EMC | EN 55022:2010 |
EN 61000-4-3:2010 | |
EN 61000-4-8:2010 | |
(1) Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C. (2) Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C. (3) Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. (4) Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux. (5) After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1° |
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature Range | -30°C to 650°C (-22°F to 1202°F) | |
Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater | |
-10°C to 0°C: ±2.0 | ||
-30°C to -10°C: ±3.0 | ||
Response Time (95%) | Fluke 62 MAX+ | < 300 ms (95% of reading) |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical Resolution | 12:1 (calculated at 90% energy) | |
Display Resolution | 0.1°C (0.2°F) | |
Repeatability Of Readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater | |
Power | AA battery | |
Battery Life | 8 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
Size (L x W x D) | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating Temperature | 0°C to 50°C (32°F to 122°F) | |
Storage Temperature (Without Battery) | -20°C to 60°C (-4°F to 140°F) | |
Operating Humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
Operating Altitude | 2000 meters above mean sea level | |
Storage Altitude | 12,000 meters above mean sea level | |
IP Rating | IP 54 per IEC 60529 | |
Drop Test | 3 meters | |
Vibration And Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz | |
IEC 68-2-27, 50 g, 11 ms | ||
EMC | EN 61326-1:2006 | |
EN 61326-2:2006 | ||
Standards And Agency Approval | ||
Compliance | EN/IEC 61010-1: 2001 | |
Laser Safety | FDA and EN 60825-1 Class II |