We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Fluke 1587/ET Advanced Electrical Troubleshooting Kit includes the Fluke 1587 Insulation Multimeter, the Fluke i400 current clamp and the Fluke 62 MAX + Infrared Thermometer. The 1587/ET provides equipment to perform insulation tests, measure AC current without breaking the circuit and measure temperature all within one kit. Now, maintaining the uptime of electrical equipment can be done effortlessly and efficiently.
Fluke 1587 Insulation Multimeters
Specifications | ||
Voltage DC | Maximum voltage | 1000 V |
Accuracy | ±(0.09% + 2) | |
Maximum resolution | 0.001V | |
Voltage AC | Maximum voltage | 1000 V |
Accuracy | ±(2% + 3) | |
AC bandwidth | 5 kHz1 | |
1. With low pass filter; 3 db @ 800 Hz | ||
Maximum resolution | 0.1 mV | |
Current DC | Maximum amps | 400 mA |
Amps accuracy | ±(0.2% + 2) | |
Maximum Resolution | 0.01 mA | |
Current AC | Maximum amps | 400 mA |
Amps accuracy | ±(1.5% + 2) 1 | |
1. 1 kHz bandwidth | ||
Maximum resolution | 0.01 mA | |
Resistance | Maximum resistance | 50 MΩ |
Accuracy | ±(0.9% + 2) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Maximum capacitance | 9,999 µF |
Accuracy | ±(1.2% + 2) | |
Maximum resolution | 1 nF | |
Frequency | Maximum frequency | 100 kHz |
Accuracy | ±(0.1% + 1) | |
Maximum resolution | 0.01 Hz | |
Temperature measurement | -40.0°C to 537°C | |
Diode test | Range | 6 V |
Resolution | 1 mV | |
Accuracy | ±(2% + 1) | |
Insulation Test | ||
Minimum test current @ 1 kΩ/V | 1 mA | |
Test voltages | 50, 100, 250, 500, 1000 V | |
Maximum resistance per test voltage | 50 V | |
100 V | ||
250 V | ||
500 V | ||
1000 V | 2 GΩ | |
Maximum resolution per test voltage | 50 V | 0.01 MΩ |
100 V | 0.01 MΩ | |
250 V | 0.1 MΩ | |
500 V | 0.1 MΩ | |
1000 V | 0.1 MΩ | |
Accuracy per test voltage | 50 V | ±(3% + 5) |
100 V | ±(3% + 5) | |
250 V | ±(1.5% + 5) | |
500 V | ±(1.5% + 5) | |
1000 V | ±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ | |
Environmental Specifications | ||
Operating temperature | –20°C to +55°C | |
Storage temperature | -40°C to +60°C | |
Humidity (without condensation) | 0% - 95% (10°C – 30°C) | |
0% - 75% (30°C – 40°C) | ||
0% - 40% (40°C – 55°C) | ||
Operating altitude | 2000 m | |
Safety Specifications | ||
Overvoltage category | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V | |
Agency approvals | 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V | |
Mechanical and General Specifications | ||
Size | 203 x 100 x 50 mm (with holster) | |
Weight | 624 g | |
Warranty | 3 years | |
Battery life Alkaline | Meter use | 1000 hours |
Insulation test use | Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. | |
IP Rating | IP40 |
Fluke i400 AC Current Clamp
Specifications | |
Nominal current range | 400 A |
Continuous current range | 1 A - 400 A |
Maximum non-destructive current | 1000 A |
Lowest measurable current | 1 A |
Basic accuracy | 2% + 0.06 A |
Useable frequency | 5 Hz - 20 kHz |
Output level(s) | 1 mA/A |
Safety Specifications | |
Safety | CAT IV 600 V, CAT III, 1000 V |
Maximum voltage | 1000 V AC rms from earth to ground, in compliance with EN61010 |
Mechanical and General Specifications | |
Warranty | 1 year |
Maximum conductor diameter | 32 mm (1.25 in) |
Maximum conductor size (busbar) | 750 MCM |
Output cable length | 1.5 m (59 in) |
Shrouded banana plugs | Yes |
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature range | -30°C to 650°C (-22°F to 1202°F) | |
Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater | |
Response time (95%) | Fluke 62 MAX+ | < 300 ms (95% of reading) |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | 12:1 (calculated at 90% energy) | |
Display resolution | 0.1°C (0.2°F) | |
Repeatability of readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater | |
Power | AA battery | |
Battery life | 8 hours with laser and backlight on | |
Physical specifications | Weight | 255 g (8.99 oz) |
Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0°C to 50°C (32°F to 122°F) | |
Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
Operating altitude | 2000 meters above mean sea level | |
Storage altitude | 12,000 meters above mean sea level | |
IP rating | IP 54 per IEC 60529 | |
Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and agency approval | Compliance | EN/IEC 61010-1: 2001 |
Laser safety | FDA and EN 60825-1 Class II |