Crystal Engineering APMi Intrinsically Safe Advanced Pressure Module

SKU
APMi
Manufacturer:
Crystal Engineering
Crystal Engineering

Key Features:

  • Accuracy to 0.035% of Reading
  • Temperature Compensated from -20 to 50°C
  • Integrated CPF Connection
  • Eight Ranges Available
  • Rugged Cast Aluminum Housing
  • Self-Contained, Intelligent Module
Product Options:
Special Price $1,905.66 Regular Price $1,983.00

Secured and trusted checkout with

The Crystal Engineering APMi is able to read up to four pressure inputs with a single HPC50 handheld pressure calibrator. The APMi can either expand the range of the HPC50, view all four readings at the same time, or read two different differential pressures simultaneously.

Accuracy

psi (Gauge Pressure)
18 to 28° C
0 to 30% of Range:±(0.01% of Full Scale)
30 to 110% of Range:±(0.035% of Reading)
Vacuum* :±(0.05% of Full Scale**)
 
-20 to 50° C
0 to 30% of Range:±(0.015% of Full Scale)
30 to 110% of Range:±(0.050% of Reading)
Vacuum* :±(0.05% of Full Scale**)
* Applies to 300 psi / 30 bar / 3 MPa and lower ranges only.
   Vacuum Range = -14.5 psi / -1.0 bar / -1MPa.
** Full Scale is the numerical value of the positive pressure range.

 

psiA (Absolute Pressure with HPC50 BARO Option)
All absolute accuracies are equivalent to the gauge pressure accuracies, except as noted below.
15 psi / 1 bar/100 kPa Range:Gauge Accuracy + 0.005 psiA
30 psi / 3 bar / 300 kPa Range:Gauge Accuracy + 0.005 psiA
100 psi / 10 bar / 1MPa Range:Gauge Accuracy + 0.002 psiA
Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year.

Exposure to environmental extremes of temperature, shock, and/or vibration may warrant a more frequent recertification period.

All models indicate vacuum, but vacuum specification applies only where specified.

Not recommended for continuous use at high vacuum. Refer to XP2i-DP data sheet for gauges that are intended for continuous high vacuum use.

The BARO option allows you to toggle between gauge and absolute pressure using the same APMi module.


Sensor

Wetted Materials(wrench tight) 316 stainless steel
(finger tight) 316 stainless steel
and Viton® (internal o-ring)
(15 psi / 1 bar / 100 kPa)
316 stainless steel and Viton
Diaphragm Seal FluidSilicone Oil
ConnectionCrystal CPF Female
All welded, with a permanently filled diaphragm seal.

Metal to metal cone seal; O-ring can be removed if necessary.

1/4" male NPT adapter is included unless BSP or M20 is specified.

1/4" medium pressure tube system is compatible with HIP LM4 and LF4
Series, Autoclave Engr SF250CX Male and Female Series.


Output

Pressure Resolutionup to 6 digits
Display Updateup to 10 per second
Pressure resolution and display update are the maximum values available.

The resolution of your Crystal device may be different.


Pressure Overload

Overload Alarm"+OL" in display at 110% F.S.


Operating Temperature

Temperature Range-20 to 50° C (-4 to 122° F)
< 95% RH, non-condensing. No change in accuracy over operating temperature range , except as noted in the accuracy specifications. Gauge must be zeroed to achieve rated specification.

Applies to all modules.

 

Storage Temperature

Temperature Range-40 to 75° C (-40 to 167° F)


Enclosure

Dimensions2.9 x 1.1 in (74.0 x 27.0 mm)
Weight0.39 lbs (176.0 g)


Intrinsic Safety Approvals

 Atex image
ATEX
Ex ia IIC T4/T3 Ga
FTZU 18 ATEX 0043X
IEC IECExEx ia IIC T4/T3 Ga
IECEx FTZU 18.0012X
SAExia Intrinsically Safe and Non-Incendive for Hazardous
Locations: Class I, Division 1, Groups A, B, C, and D; Temperature
Code T4/T3. Class I, Zone 0, AEx ia IIC T4/T3 Ga.



Entity Parameters

Ui = 5.0 V
li = 740 mA
Pi = 880 mW
Ci = 9.2 μF
Li = 12 μH


Certifications

CEWe declare that the APMi is in accordance with
the Electromagnetic Compatibility Directive per
our declaration(s).



Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account