The BK Precision 4062B is capable of generating stable and precise sine, square, triangle, pulse, and arbitrary waveforms. The 4062B is equipped with a sine frequency range of 1 μHz to 40 MHz.
Model | 4062B | 4063B | 4064B |
Channels | 2 | ||
Frequency Characteristics | |||
Sine | 1 µHz to 40 MHz | 1 µHz to 80 MHz | 1 µHz to 120 MHz |
Square | 1 µHz to 25 MHz | ||
Triangle, Ramp | 1 µHz to 1 MHz | ||
Pulse | 1 µHz to 25 MHz | ||
Gaussian Noise (-3 dB) | > 120 MHz | ||
Arbitrary | 1 µHz to 20 MHz | ||
Accuracy | ± 1 ppm (1 year) | ||
Resolution | 1 µHz | ||
Arbitrary Characteristics | |||
Built-in Waveforms | 196 | ||
Waveform Length | 8 points to 8 M points | ||
Vertical Resolution | 16 bits | ||
Sampling Rate | 300 MSa/s (DDS mode) 75 MSa/s (true arbitrary mode) | ||
Minimum Rise/Fall Time (typical) | 4.5 ns (DDS mode) 8.5 ns (true arbitrary mode) | ||
Jitter (rms) | < 150 ps (1 Vpp, into 50 Ω load, true arbitrary mode) | ||
Non-volatile Memory Storage | 80 MB file system | ||
Output Characteristics | |||
Amplitude Range(1) (into open circuit) | 2 mVpp to 20 Vpp ( ≤ 20 MHz) 2 mVpp to 10 Vpp ( > 20 MHz) | ||
Amplitude Resolution | Up to 4 digits | ||
Amplitude Accuracy (10 kHz, 0 V offset) | ± (1% + 1 mVpp) | ||
Amplitude Flatness (reference to 10 kHz Sine, 2.5 Vpp) |
± 0.3 dB (50 Ω load, DC to 100 MHz) ± 0.4 dB (50 Ω load, 100 MHz to 120 MHz) | ||
Cross Talk | < -60 dBc (between channels) | ||
Offset Range (DC) | ± 5 V (into 50 Ω load) ± 10 V (into open circuit) | ||
Offset Resolution (DC) | Up to 4 digits | ||
Offset Accuracy (DC) | ± (1% + 2 mV), into open circuit | ||
Output Impedance (typical) | 50 Ω | ||
Output Protection | Overvoltage (see user manual for details) | ||
Waveform Characteristics | |||
Harmonic Distortion (sine, 0 dBm input, typical) | DC to 10 MHz, < -65 dBc 10 MHz to 20 MHz, < -60 dBc 20 MHz to 40 MHz, < -55 dBc 40 MHz to 60 MHz, < -50 dBc 60 MHz to 80 MHz, < -45 dBc 80 MHz to 100 MHz, < -40 dBc 100 MHz to 120 MHz, < -38 dBc |
Total Harmonic Distortion (sine) | < 0.075% (10 Hz to 20 kHz at 0 dBm) |
Spurious (non-harmonic) | ≤ 50 MHz, -70 dBc max. > 50 MHz, -65 dBc max. |
Rise/Fall Time (square) | < 9 ns (10% to 90% at 1 Vpp, into 50 Ω load) |
Variable Duty Cycle (square) | 0.001% to 99.999% (depending on frequency setting) |
Jitter (rms) Cycle to Cycle (square) | 150 ps (1 Vpp, into 50 Ω load, typical) |
Ramp Symmetry | 0% to 100% |
Ramp Linearity | < 1% of peak output (triangle, ramp at 1 kHz, 1 Vpp, 100% symmetry) |
Pulse | |
Pulse Width | 16.3 ns minimum |
Rise/Fall Time | 8.4 ns to 22.4 s (1 Vpp, 10% to 90%, into 50 Ω load) |
Duty Cycle Range | 0.001% to 99.999% (depending on frequency setting) |
Overshoot | < 3% (100 kHz, 1 Vpp) |
Jitter (rms) Cycle to Cycle | 150 ps (1 Vpp, into 50 Ω load) |
Burst | |
Waveform | Sine, square, ramp, pulse, arbitrary, noise |
Type | Cycle (1 to 1,000,000 cycles), infinite, gated |
Start/Stop Phase | 0º to 360º |
Internal Period | 1 µs to 1000 s |
Gated Source | Internal, external trigger |
Trigger Source | Internal, external, manual |
Phase Offset | |
Range | -360º to 360º |
Resolution | 0.1º |
AM, FM & PM Modulation Characteristics | |
Carrier(2) | Sine, square, ramp, arbitrary |
Source | Internal, external |
Modulation Waveform | Sine, square, ramp, noise, arbitrary |
AM Modulation Depth | 0% to 120% |
FM Frequency Deviation | 0 to 0.5 x (maximum output frequency) |
PM Phase Deviation | 0º to 360º |
ASK & FSK Modulation Characteristics | |
Carrier(2) | Sine, square, ramp, arbitrary |
Source | Internal, external |
Modulation Waveform | 50% duty cycle square waveform |
(1) This specification will be divided by 2 while applied to a 50 Ω load.
(2) Modulation schemes not available in DC mode.
Model | 4062B, 4063B, 4064B | |
DSB-AM Modulation Characteristics | ||
Carrier(2) | Sine, square, ramp, arbitrary | |
Source | Internal, external | |
Modulation Waveform | Sine, square, ramp, noise, arbitrary | |
PWM Modulation Characteristics | ||
Source | Internal, external | |
Modulation Waveform(2) | Sine, square, ramp, noise, arbitrary | |
Internal Modulation Frequency | 1 mHz to 1 MHz | |
Sweep Characteristics | ||
Waveforms(2) | Sine, square, ramp, arbitrary | |
Sweep Shape | Linear or logarithmic, up or down | |
Sweep Time | 1 ms to 500 s | |
Sweep Trigger | Internal, external, manual | |
Harmonic Output Characteristics | ||
Maximum Order | 16 | |
Type | Even, odd, all | |
Auxiliary Input / Output | ||
Sync Out | TTL compatible(4) Output impedance: 100 Ω (typical) Maximum frequency: 10 MHz Minimum pulse width: 50 ns (typical) | |
Modulation Input | ± 12 Vpp (typical) for 100% modulation Input impedance: 10 kΩ Frequency range: 0 kHz to 50 kHz | |
Trigger | ||
Input | Level | TTL compatible(3) |
Slope | Rising or falling, selectable | |
Pulse Width | > 100 ns | |
Impedance | > 100 kΩ | |
Latency | 100 ns maximum (sweep mode) 600 ns maximum (burst mode) | |
Output | Voltage Level | TTL compatible(4) |
Pulse Width | > 500 ns | |
Impedance | 100 Ω (typical) | |
Maximum Frequency | 1 MHz | |
Reference Clock | ||
Input | Frequency range: 10 MHz (typical) Minimum voltage input: 1.4 Vpp Input impedance: 5 kΩ | |
Output | Frequency range: 10 MHz (typical) Voltage level: 3.3 V (typical), 2 V (minimum) Output impedance: 50 Ω |
Frequency Counter | |
Measurement | Frequency, period, positive/negative pulse width, duty cycle |
Measurement Range | 100 mHz to 200 MHz (DC coupling) 10 Hz to 200 MHz (AC coupling) |
Input Range | 100 mVrms to ± 2.5 V (< 100 MHz, DC coupling) 200 mVrms to ± 2.5 V (100 MHz to 200 MHz, DC coupling) 100 mVrms to 5 Vpp (< 100 MHz, AC coupling) 200 mVrms to 5 Vpp (100 MHz to 200 MHz, AC coupling) |
Input Impedance | 1 MΩ (typical) |
Coupling | AC, DC, HF REJ (≥ 250 kHz filter) |
Environmental and Safety | |
Temperature | Operating: 32 °F to 104 °F (0 °C to 40 °C) Storage: -4 °F to 140 °F (-20 °C to 60 °C) |
Humidity | < 86 °F (30 °C), ≤ 90 % RH 104 °F (40 °C), ≤ 50 % RH |
Altitude | Operating: below 10,000 ft (3,048 m) Storage: below 49, 212 ft (15,000 m) |
Electromagnetic Compatibility | EMC Directive 2014/30/EU, EN61326-1:2013 |
Safety | Low voltage directive (LVD) 2014/35/EU, EN61010-1:2010 |
General | |
Display | 4.3” TFT color (24-bit) LCD touch screen |
I/O Interfaces | USBTMC device, LAN, USB host port |
Storage Memory | 10 instrument settings |
AC Input | 100 to 240 VAC ± 10 %, 50/60 Hz 100 to 120 VAC ± 10 %, 400 Hz |
Power Consumption | 50 W maximum |
Dimensions (W x H x D) | 10.25” x 4.22” x 11.61” (260.3 x 107.2 x 295 mm) |
Weight | 7.6 lbs (3.43 kg) |
Warranty | 3 years |
Standard Accessories | AC power cord, user manual (downloadable), USB type A-to-B cable, BNC coaxial cable, certificate of calibration |
Optional Accessories | USB-to-GPIB adapter (model AK40G) |
(2) Modulation schemes not available in DC mode.
(3) VIH = 2 V to 5.5 V, VIL = 0.5 V to 0.8 V
(4) VOH = 3.8 V (IOH = -8 mA), VOL = 0.44 V (IOL = 8 mA)