BK Precision 2682 2.1 GHz Spectrum Analyzer

SKU
2682
Manufacturer:
B&K Precision
B&K Precision

Key Features:

  • Frequency range: 9 kHz to 2.1 GHz
  • High Sensitivity -161 dBm/Hz displayed average noise level (DANL)
  • Low phase noise of -98 dBc/Hz @ 10 kHz offset
  • Low level uncertainty of ±0.7 dB
  • 1 Hz minimum resolution bandwidth (RBW)
  • Preamplifier and tracking generator standard on all models
  • 10.1” wide-screen 1024 x 600 color display
  • LAN and USBTMC connectivity
  • USB host port to store and recall waveform data, setups, and screen captures
Product Options:
$2,995.00

Secured and trusted checkout with

The BK Precision 2682 is a spectrum analyzers that delivers performance and functionality in frequency ranges from 9 kHz to 2.1 GHz. The 2682 offers a standard pre-amplifier, tracking generator, and 1 Hz minimum RBW. The included advanced measurements give the user access to even more powerful features. Model 2682 is ideal for applications in 2-way radio, site surveying, EMI pre-compliance, characterizing the frequency response of RF devices and more.

Series

2682

2683

Frequency characteristics

Frequency Range

9 kHz to 2.1 GHz

9 kHz to 3.2 GHz

Frequency Resolution

1 Hz

Frequency Span

0 Hz, 100 Hz to 2.1 or 3.2 GHz

Frequency Span Accuracy

±Span / (number of sweep points -1)

Internal reference source

Reference Frequency

10 MHz

Initial Calibration Accuracy

<1 ppm

Temperature Stability

<1 ppm/year,  0 °C to +50 °C

Frequency Aging Rate

<0.5 ppm/first year, 3.0 ppm/20 year

Frequency Reference

Accuracy

±[(time since last adjustment × frequency aging rate) + temperature stability + calibration accuracy]

Marker

Marker Resolution

Span / (number of sweep points -1)

Marker Uncertainty

± [frequency indication  x frequency reference uncertainty + 1% x span  + 10% x resolution bandwidth + marker resolution]

Frequency Counter Resolution

1 Hz

Frequency Counter

Uncertainty

± [frequency  indication  x frequency reference accuracy + counter resolution]

Bandwidths

Resolution Bandwidth (-3 dB)

1 Hz to 1 MHz, in 1-3-10 sequence

Resolution Filter Shape Factor

<4.8:1 (60 dB: 3 dB), Gaussian-like

RBW Uncertainty

<5%

Video Bandwidth (-3 dB)

1 Hz to 3 MHz, in 1-3-10 sequence

VBW Uncertainty

<5%

Amplitude and level

Measurement Range

(preamplifier off)

DANL to +10 dBm, 100 kHz to 1 MHz

DANL to +20 dBm,1 MHz to 3.2 GHz

Reference Level

-100 dBm to +30 dBm, 1 dB steps

Preamplifier

20 dB (nom.), 9 kHz to 3.2 GHz

Input Attenuation

0 to 51 dB,  1 dB steps

Maximum Input DC Voltage

±50 Vdc

Maximum Average RF Power

30 dBm, 3 minutes, fc >equal to 10 MHz, attenuation >20 dBm, preamplifier off

Maximum Damage Level

33 dBm, fc >equal  10 MHz, attenuation  >20 dBm, preamplifier off

 

Displayed average noise level (DANL)
 20 °C to 30 °C ,attenuation = 0 dB, sample detector,
trace average >50
  RBW=10 HzNormalization to 1 Hz



Preamp Off
9 kHz to 100 kHz-100 dBm (nom.)-100 dBm (nom.)
100 kHz to 1 MHz-97 dBm,
-101 dBm (typ.)
-107 dBm,
-111 dBm (typ.)
1 MHz to 10 MHz-122 dBm,
-126 dBm (typ.)
-132 dBm,
-136 dBm (typ.)
10 MHz to 200 MHz-127 dBm,
-131 dBm (typ.)
-137 dBm,
-141 dBm (typ.)
200 MHz to 2.1 GHz-125 dBm,
-129 dBm (typ.)
-135 dBm,
-139 dBm (typ.)
2.1 GHz to 3.2 GHz-116 dBm,
-122 dBm (typ.)
-126 dBm,
-132 dBm (typ.)



Preamp On
9 kHz to 100 kHz-107 dBm (nom.)-117 dBm (nom.)
100 kHz to 1 MHz-122 dBm,
-127 dBm (typ.)
-132 dBm,
-137 dBm (typ.)
1 MHz to 10 MHz-138 dBm,
-144 dBm (typ.
-148 dBm,
-154 dBm (typ.)
10 MHz to 200 MHz-146 dBm,
-151 dBm (typ.)
-156 dBm,
-161 dBm (typ.)
200 MHz to 2.1 GHz-145 dBm,
-148 dBm (typ.)
-155 dBm,
-158 dBm (typ.)
2.1 GHz to 3.2 GHz-135 dBm,
-139 dBm (typ.)
-145 dBm,
-149 dBm (typ.)
Phase noise
Carrier Offsetfc=1 GHz, 20 ºC ~30 ºC
10 kHz<-95 dBc/Hz, <-98 dBc/Hz (typ.)
100 kHz<-96 dBc/Hz, <-97 dBc/Hz (typ.)
1 MHz<-115 dBc/Hz , <-117 dBc/Hz (typ.)
Level display
Logarithmic Level Axis10 dB to 100 dB
Linear Level Axis0 to reference level
Units of Level AxisdBm, dBmV, dBμV, dBμA , V, W
Number of Display Points751
Number of Traces4
Trace DetectorsPositive-Peak, Negative-Peak, Sample, Normal,
Average (Voltage/RMS/Video),
Quasi-Peak (with EMI option)
Trace FunctionsClear Write, Max Hold, Min Hold, View,
Blank, Average

 

 

Frequency response

 

Preamplifier

Off

±0.8 dB,
±0.4 dB typ.

On

±0.9 dB,
±0.5 dB typ.

Error and accuracy

Resolution Bandwidth
Switching Uncertainty

1 Hz RBW
Logarithmic resolution ±0.2 dB,
Linear resolution ±0.01, nom.

Input Attenuation
Switching Uncertainty

20 °C to 30 °C, fc = 50 MHz, preamp off,
Relative to 20 dB, 1 to 51 dB attenuation ±0.5 dB

Absolute Amplitude Accuracy

Preamplifier off: ±0.4 dB, input signal -20 dBm
Preamplifier off: ±0.5 dB, input signal -40 dBm



Total Amplitude Accuracy

±0.7 dB
20 °C to 30 °C , Fc>100 kHz, input signal -50 dBm
to 0 dBm, RBW = 1 kHz, VBW = 1 kHz, peak
detector, attenuation = 20 dB,preamp off,
95th percentile reliability

RF Input  VSWR

<1.5 nom.
Input attenuation  10 dB, 1 MHz to 3.2 GHz

Distortion and spurious responses

Second Harmonic Distortion

-65 dBc
fc ≥50 MHz, Mixer Level -30 dBm,
attenuation = 0 dB, preamp off, 20 °C to 30 °C

 
Third-Order Intercept

+10 dBm
fc ≥50 MHz, two -20 dBm tones at input mixer
spaced by 100 kHz, attenuation = 0 dB, preamp off,
20 °C to 30 °C

 
1 dB Gain Compression

>-5 dBm, nom.
fc ≥50 MHz, attenuation = 0 dB, preamp off,
20 °C to 30 °C


Residual Response

<-90 dBm, typ.
input terminated = 50 Ω,attenuation = 0 dB,
20 °C to 30 °C

Input Related Spurious

<-65 dBc
Mixer level = -30 dBm, 20 °C to 30 °C

Sweep and trigger

Sweep Time

1 ms to 3000 s

Sweep Accuracy

Accuracy, Speed

Sweep Mode

Sweep,  FFT

Sweep Rule

Single, Continuous

Trigger Source

Free, Video, External

External Trigger

5 V TTL level,  1 kΩ, BNC-female,
rising edge/falling edge

 

Tracking generator

Frequency Range

100 kHz to 2.1 GHz

100 kHz to 3.2 GHz

Output Level

-20 dBm to 0 dBm

Output  Level Resolution

1 dB

Output Flatness

±3 dB

Output Maximum
Reserve Level

Mean power: 30 dBm, DC: ±50 Vdc

EMI Pre-compliance option (EMI2680)

Resolution Bandwidth (6 dB)

200 Hz, 9 kHz, 120 kHz

Detector

Quasi-peak  (following CISPR 16-1-1)

Dwell Time

0 µs to 10 s

Reflection measurement option (RFL2680)

Measurements

VSWR, Return loss, Reflect coefficient

RF and 10 MHz input/output

Front panel RF input

50 Ω, N-female

Front panel TG output

50 Ω, N-female

10 MHz reference  output

10 MHz, >0 dBm, 50 Ω, BNC-female

10 MHz reference  input

10 MHz, -5 dBm to +10 dBm, 50 Ω, BNC-female

General

AC Input

100 V - 240 V, 50 Hz/60 Hz/400 Hz AC

Display

TFT LCD, 1024 × 600 (waveform area 751 × 501),

10.1”


I/O Interface

USB host (type A) USB 2.0
USB device (type B) USB 2.0
LAN 10/100 Base T, RJ45

Temperature

Operating: 0 °C to 50 °C
Storage: -20 °C to 70 °C

Humidity

0 °C to 30 °C , ≤95% RH
30 °C to 50 °C , ≤75% RH

Safety

EN 61010-1:2010, Low Voltage Directive  (LVD)
2014/35/EU

Electromagnetic Compatibility

EN 61326-1:2013, EMC Directive  2014/30/EU

Dimensions  (W x H x D)

15.47” x 8.15” x 4.59”
(393 mm x 207 mm x 116.5 mm)

Weight

10.1 lb (4.60 kg)

Warranty

3 years

Included Accessories

Power cord, certificate of calibration

Optional Accessories

EMC Near-field probes (PR262),
reflection bridge (RB2680)

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series

As low as

Now $4,690.00