BK Precision 2652A 3.3 GHz Handheld Spectrum Analyzer

SKU
2652A
Manufacturer:
B&K Precision
B&K Precision

Key Features:

  • DANL (displayed average noise level) of -127 dBm
  • Fast sweep speed, minimum 10 ms, to help locate and identify elusive, transient interference signals
  • Impressive 4 hour battery life; easy-to-replace rechargeable Lithium-Ion battery
  • Measurement functions: channel/adjacent channel power, occupied bandwidth, electric and magnetic field strength
  • Built-in tracking generator to rapidly determine transmission characteristics of 2 port devices (model 2652A)
  • Convenient Auto tune function
  • Large easy-to-read color display, 640 x 480 resolution
  • PC Software for remote control and documentation of measurement results (included)
  • Conveniently store measurement results and screen shots in bitmap format to USB flash drive
  • Product Options:
    $8,550.00

    Secured and trusted checkout with

    The 2650A series of compact, light weight and cost-effective spectrum analyzers are for quick and precise signal investigations, especially away from the bench. At a weight of only 4 pounds (1.8 kg), these instruments are by far the lightest full-featured handheld spectrum analyzers available, yet they deliver performance and features comparable to a full-size bench spectrum analyzers and can operate up to 4 hours on a single battery.

    With their ease of use, measurement flexibility and unmatched portability, the 2650A series are an indispensible tool for engineers and technicians who conduct field measurements in the 50 kHz to 8.5 GHz range.




    models2650A, 2652A2658A
    Frequency section  
    Frequency range 50 kHz to 3.3 GHz 50 kHz to 8.5 GHz
    Center frequency  
         Setting 20 kHz  
         resolution  Settable with rotary encoder, numeric or function key 
         Accuracy

     within ± (30+20T) kHz±1 dot
     @frequency span: 200 kHz to 10 MHz, RBW 3 kHz, 23±5 °C

     within ± (60+300T) kHz±1dot
     @frequency span: 20 MHz to max. frequency (3.3 GHz or 8.5 GHz), RBW 100 kHz,
     23±5 °C

     T: sweep time (s)

         RBW frequency error within ±4 kHz @ 3 kHz, 10 kHz, 30 kHz
     within 20% of RBW @ RBW: 100 kHz, 300 kHz
     within 10% of RBW @ RBW: 1 MHz, 3 MHz 
    Frequency span  
          Range

     0 Hz (zero span), 

     200 kHz to 2 GHz (1-2-5 step) and 

     3.3 GHz (full span)

     0 Hz (zero span), 

     200 kHz to 5 GHz (1-2-5 step) and 

     8.5 GHz (Full span)

          Accuracy within ±3% ±1dot @ sweep time of 0.3s, 23±5 °C 

    Display resolution

    # of points per trace

     501dots on LCD screen, 1001dots readout via PC 

     (501 dots are visible on the display, 1001 dots of trace data are captured internally

     and can be transferred to a PC via USB device interface.)

    Resolution bandwidth 3 dB bandwidth 
         Range 3 kHz to 3 MHz (1-3 sequence) and AUTO 
         Accuracy ±20% 
         Shape Factor 1:12 (typical, 3 dB : 60 dB) 
    Video bandwidth 100 Hz to 1 MHz (1-3 step) and AUTO 
    SSB phase noise -90 dBc/Hz (typical) @100 kHz offset, RBW : 3 kHz, VBW : 100 Hz, sweep time: 1 s
    Spurious response less than -60 dBc
    Harmonics less than -40 dBc @ ≥ 100 MHz
    Amplitude section
    Reference level 
          Range +10 to -60 dBm (1dB step)
          Accuracy within ± 0.8 dB ± 1 dot @ center frequency : 100 MHz, RBW : 3 MHz,
     VBW : 1 MHz, REF : -15 dBm, 23±5 °C
          Unit dBm, dBV, dBmV, dBμV, dBμV/m, dBμA/m
     (dBμV/m and dBμA/m are used for measurement functions)
    Average noise level -127 dBm (typical) @ CF : 1 GHz, RBW : 3 kHz, VBW : 100 Hz,
     Ref. level < - 40 dBm ( preamp automatically ON)
    Frequency response within ±2.0 dB ± 1 dot @50 kHz to 100 MHz
     within ±1.0 dB ± 1 dot @100 MHz to max. frequency (3.3 GHz or 8.5 GHz)
    Input impedance 50 Ω
    Input VSWR < 2.0
    Input attenuator 
         Operating range 0 to 25 dB (1 dB step), coupled with reference level
         Switching error  ±0.6 dB @100 MHz
    RBW switching error ±0.6 dB
    Display resolution (vertical) 381 dots/10 div
    Display scale 
         Scale 10 dB/div, 5 dB/div, 2 dB/div
         Accuracy ±(0.2 dB+1dot)/2 dB ±(0.4 dB+1dot)/5 dB
     ±(0.8 dB+1dot)/10 dB ±(1.8 dB+1dot)/83 dB
    Input damage level +27 dBm (CW average power), 25 VDC
    Sweep section
    Sweep time 

         Range

         (1-3 step)

     10 ms to 30 s and AUTO

     @frequency span : 0 to 2 GHz

     30 ms to 30 s and AUTO

     @frequency span : full span

     10 ms to 30 s and AUTO

     @frequency span : 0 to 2 GHz

     30 ms to 30 s and AUTO

     @frequency span : 5 GHz, full span

    Accuracy

     Within ±0.1 %±1dot

     @frequency  span : 0 to 2 GHz

     within ±1.5 %±1dot @ full span

     Within ±0.1 %±1dot

     @frequency  span : 0 to 5 GHz

     within ±2.5 %±1dot @ full span

    Trigger

     

     

     Trigger mode

     AUTO (Available only for zero span)

     Trigger source

     Internal and External

     External trigger

     

       Input voltage range

     1 to 10 Vp-p

       Frequency range

     DC to 5 MHz

       Input coupling

     DC coupling

       Trigger level

     approx. 0.56 V(fix)

       Input RC

     approx. 10 kΩ / less than 15 pF

       Input damage level

     ±50 V(DC+AC  peak)

       Input connector

     SMA(J)

    Detection mode

     Positive peak, Negative peak, Sample

    Function

    Marker measurement

     NORM:displays  frequency (8 digits max) and level (4 digits max) at marker point.

     DELTA:displays frequency difference and level difference between two markers.

    Peak search

     NORM:  searches peak point  within  10div  (full freq. range). This mode also supports  NEXT  peak

     ( up to 10).

     ZONE:  searches peak point  within  a zone designated by center and width

    Calculations

     NORM, MAX HOLD, MIN HOLD, AVERAGE, OVER WRITE

     MAX/MIN HOLD: 2 to 1024

     AVERAGE: 2 to 256

    Measurements

     Measure Channel power, Adjacent channel leakage power, Occupied  frequency bandwidth,

     Electric field strength (requires antenna), Magnetic field strength (requires magnetic field probe).

    Auto tuning

     Automatically  scans the full bandwidth,  sets center frequency to the maximum signal within full

     span and centers it onscreen. Automatically  adjusts reference level, RBW, VBW and sweep time

    to optimum values

    Save/Load

     

     

    Save

     Saves 200 reference spectrum measurements and 200 setups

    Load

     Loads one reference spectrum measurement and one setup

    General
    RF Input  connector N(J) connector
    USB Communication 
          Protocol USB version 1.1 (will also work with USB 2.0 devices)
          Device Connector B plug
          Transfer rate 12 Mbps
    Hard copy USB printer (option) connected to A plug (host)  enables hard copy of screen.
    Host connector A plug
    Display 
          Display 5.7 inch color TFT LCD
          Backlight LED backlight
          Number of dots 640(H)  x 480(V) dots
    Power supply 
          Dedicated Input : 100 to 240 VAC
          AC adaptor Output : 9 VDC/2.6 A
          Lithium-ion battery 7.4 V/5000  mAh Li-Ion battery (MB400)
            Charge function

     Capable of charging during power-off.

     Indicates 4 conditions with two color LED
            Charge indicator 5 level indicator of remaining battery charge

    Environmental and Size

    Operating temperature 0 to 50° C (guaranteed at 23±10 °C, without soft carrying case)
    Operating humidity less than 40 °C/80  %RH (guaranteed at less than 33 °C/70  %RH, without soft carrying case)
    Storage temperature -20 to 60 °C, less than 60 °C/70  %RH
    Dimensions

     6.38 (W) x 2.80 (H) x 10.43  (D) inch, 162(W) x 71(H) x 265(D)  mm

     (excluding projections, protection  bumper and stand)

    Weight approx. 1.8 kg or 4 lbs (including battery)
    Three Year Warranty
    Accessories
       Included
     User manual, AC adaptor MA400, soft carrying case LC2650A, accessory
     pouch, PC software and USB cable, Lithium-Ion battery MB400, certificate of calibration.
       Optional Dipole antennas M401 – M406, magnetic field probe PR 26M, printer
     PT2650A and extra roll paper PX2650A
    Write Your Own Review
    Only registered users can write reviews. Please Sign in or create an account
  • Installation, maintenance, and troubleshooting of wireless communication systems such as W-CDMA/CDMA, GSM, WLAN, WiMAX and Bluetooth
  • Frequency response measurements of passive components such as RF cables, filters, and attenuators (2652A only)
  • Detection of signal interference and undesired emissions
  • TV and broadcasting
  • Antenna alignment
  • Electric field strength measurement with dipole antennas (order M401-M406)
  • Magnetic field strength measurement with magnetic field probe (order PR 26M)