We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Amprobe’s AT-6010/Kit Wire Tracer Kit with Digital Multimeter is the perfect residential and commercial electrical maintenance kit. Made for inspection and verification of indoor electrical installations, the AT-6010/KIT comes with the top selling AT-6010 Wire Tracer and the AM-530 True-rms Electrical Contractor Multimeter. Users can troubleshoot voltage, perform repairs, run new wiring, check continuity, trace and locate wires and breakers and identify wire shorts rapidly and accurately. The AT-6010/KIT is the essential product bundle for professional electricians operating in demanding indoors environments.
Amprobe AT-6010 Advanced Wire Tracer Kit
Features | AT-6010-R Receiver | AT-6010-T Transmitter |
Measurement category | CAT III 600 V | |
Operating voltage/current | 0 to 600 V | |
Operating frequency | Energized: 6.25 kHz | |
Hazardous voltage detection | N/A | > 30 V AC/DC |
Signal indications | Numeric bar graph display and audible beep | LEDs |
Response time | Tip Sensor (Energized/De-energized): 500 ms Battery voltage monitoring: 5 sec | Line voltage monitoring: 1 sec Battery voltage monitoring: 5 sec |
Current output of signal (typical) | N/A | Energized circuit: HI mode: 60 mA RMS De-energized circuit: HI mode: 130 mA RMS Loop mode: 160 mA RMS |
Signal voltage output (nominal) | N/A | De-energized circuit: HIGH: 33 V RMS, 140 Vp-p With CT-400: Loop model: 31 V RMS, 120 Vp-p |
Range detection (open air) | Tip Sensor (Energized): Max distance via air: up to 20 ft (6.1 m) Pinpointing: approx. 1.97 in (5 cm) Tip Sensor (De-energized): Max distance via air: up to 14.7 ft (4.5 m) Pinpointing: approx. 1.97 in (5 cm) | N/A |
Display size | LCD 2.5 in (6.35 cm) | N/A |
Display dimensions (W x H) | 1.45 x 1.93 in (36.72 x 48.96 mm) | N/A |
Display type | Segment LCD | LEDs |
Display color | Black and white | Operating mode LEDs: red Battery status LED: red |
Booting time | < 3 sec | < 2 sec |
Backlight | Yes | N/A |
Operating temperature | -4 °F to 122 °F (-20 °C to 50 °C) | |
Operating humidity | 45%: -4 °F to <50 °F (-20 °C to <10 °C) 95%: 50 °F to <86 °F (10 °C to <30 °C) 75%: 86 °F to <104 °F (30 °C to <40 °C) 45%: 104 °F to 122 °F (40 °C to 50 °C) | |
Storage temperature and humidity | -4 °F to 158 °F (-20 °C to 70 °C), <95% RH | |
Operating altitude | 0 to 6561 ft (2000 m) | |
Transient protection | N/A | 6.00 kV (1.2/50μS surge) |
Pollution degree | 2 | |
IP rating | IP 52 | IP 40 |
Drop test | 3.28 ft (1 m) | |
Power supply | 4 x AA (alkaline) | 8 x AA (alkaline) |
Power consumption (typical) | 70 mA | Hi mode: 70 mA Loop mode with Clamp: 90 mA Consumption without signal transmission: 10 mA |
Battery life | Approx. 25 h | Hi mode: approx. 25 h Loop mode: approx. 18 h |
Low battery indication | Yes | |
Fuse | N/A | 1.6 A, 700 V, fast-acting, Ø 6x32mm |
Dimensions (L x W x H) | Approx. 7.2 x 2.95 x 1.69 in (183 x 75 x 43 mm) | Approx. 7.2 x 3.66 x 1.97 in (183 x 93 x 50 mm) |
Weight | Approx. 0.6 lb (0.27 kg) | Approx. 1.25 lb (0.57 kg) |
Certifications |
Amprobe AM-530 True-RMS Electrical Contractor Multimeter
FEATURE | AM-530 | Best Accuracy |
True-rms | X | |
AC Voltage | 400 mV, 4.000 V, 40.00 V, 400.0 V, 600 V | +/- (1.0 % rdg + 3 LSD) @ 45 Hz to 400 Hz, 4 V to 400 V ranges |
DC Voltage | 400 mV, 4.000 V, 40.00 V, 400.0 V, 600 V | +/- (0.8% rdg + 1 LSD) @ 4 V to 400 V ranges |
AC Current | 400.0 μA, 4000 μA, 40.00 mA, 400.0 mA, 4.000 A, 10.00 A | +/- (1.2% rdg + 3 LSD) @ 400 μA to 400 mA ranges, 45 Hz to 400 Hz |
DC Current | 400.0 μA, 4000 μA, 40.00 mA, 400.0 mA, 4.000 A, 10.00 A | +/- (1.0% rdg + 2 LSD) @ 400 μA to 400 mA ranges |
Frequency | 10 Hz to 10 MHz | +/- (0.1% rdg + 4 LSD) |
Resistance | 400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ | +/- (1.0% rdg + 2 LSD) @ 4 kΩ to 400 kΩ ranges |
Capacitance | 40.00 nF, 400.0 nF, 4.000 μF, 40.00 μF, 400.0 μF, 4000 μF | +/- (3.0% rdg + 5 LSD) @ 400 nF to 40 μF ranges |
Temperature | -40 ⁰F to 1832 ⁰F -40 ⁰C to 1000 ⁰C | +/- (1.8% rdg + 6 ⁰F) @ >32 ⁰F to 212 ⁰F +/- (1.2% rdg + 3 ⁰C) @ >0 ⁰C to 100 ⁰C |
Number of temperature inputs | Single Thermocouple |