Amprobe AMP-320 600A AC/DC TRMS Clamp Meter

SKU
AMP-320
Manufacturer:
Amprobe
Amprobe

Key Features:

  • Measures AC/DC Current to 600 A and AC/DC Voltage to 600 V
  • Measures temperature from -40° to 752°F, (-40° to 400°C)
  • Measures DC Microamps output to test proper operation of the flame sensor on gas appliances
  • Measures capacitance, test diodes, and features a continuity beeper
  • Tests 3-phase sequence and motor rotation to ensure proper connection of a motor to a 3-phase system
  • Monitors inrush current during motor start-up
  • Features True-RMS sensing for accurate voltage measurements in noisy electrical environments
  • Amp-Tip function delivers precise low AC current measurements – 0 to 60 A
  • Includes a low pass filter to accurately measure voltage and current on variable frequency drives
  • Provides resistance and continuity measurement capabilities to verify the quality of electrical connections and the proper operation of motor and transformer coils
  • Provides data hold, relative zero, and MAX/MIN/AVG mode for quick analysis
  • Maximizes battery life with auto power off and low battery indicator
  • Backlit display for easy measurement viewing in bright and dim environments
  • CAT III 600 V safety rated
  • Accommodates conductors up to 1.37 inches (35 mm)
  • Includes test leads, batteries (installed), alligator clip set, banana plug K-type thermocouple, carrying case, and user manual
Product Options:
$321.99

Secured and trusted checkout with

The AMP-320 embodies all the utilities needed to measure HVAC, general electrical or motor testing application. The clamp meter allows technicians to find the temperature and capacitance measurements needed, as well as DC Microamps for testing flame sensors. The unit boasts a motor rotation, inrush current measurement for motor start-up monitoring, and 3-phase sequence testing. Likewise, the Amp-Tip function provides meticulous measurement of current down to the tenth of an Amp. This enables precise current measurement of both large and small diameter wires.

 Model

AMP-310

AMP-320

AMP-330

 

AC Clamp Meter
HVAC

AC/DC Clamp Meter
Electrical Motor Maintenance

AC/DC 1000 A Clamp Meter
Industrial Motor Maintenance

 Safety Rating

CAT III 600 V

CAT III 600 V

CAT IV 600 V, CAT III 1000 V

 Jaw Opening

1.18 in (30 mm)

1.37 in (35 mm)

2.0 in (51 mm)

 

 AC Voltage
 (True-RMS)

 

Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz)

Range: 0 to 1000 V
Accuracy: ±0.8% + 5LSD (50 to 60 Hz)
±1.5% + 5LSD (20 to 200 Hz)
±10% + 5LSD (200 to 400 Hz)

 DC Voltage

Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD

Range: 0 to 1000 V
Accuracy: ±0.8% + 5LSD

 

 AC+DC Voltage

 

Range: 0 to 600.0 V
Accuracy: 1.2% ± 7LSD (DC, 50 to 60 Hz)

Range: 0 to 1000 V
Accuracy: ±1.0% + 7LSD (50 to 60 Hz)
±1.8% + 7LSD (DC, 40 to 200 Hz)
±12% + 7LSD (200 to 400 Hz)

 AC Current
 (True-RMS)

Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 100 Hz)
±2.0% + 5LSD (100 to 400 Hz)

Range: 0 to 1000 A
Accuracy: ±1.8% + 5LSD (40 to 100 Hz)
±2.2% + 5LSD (100 to 400 Hz)
                               

 DC Current

Range: 0 to 600.0 A
Accuracy: ±2.0% + 5LSD

Range: 0 to 1000 A
Accuracy: ±1.8% + 5LSD

 

 AC+DC Current

 

Range: 0 to 600.0 A
Accuracy: ±2.2% + 7LSD (DC, 50 to 100 Hz)
±2.7% + 7LSD (100 to 400 Hz)

 Range: 0 to 1000 A
Accuracy: ±2.2% + 7LSD (DC, 40 to 100 Hz)
±2.5% + 7LSD (100 to 400 Hz)
                                                  

 


 Precise
Low
 Current AC

 


Range
: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz)

Range: 0 to 60.00 A
Accuracy:
±1.5% + 5LSD (0.00 to 20.00 A, 40 to 100 Hz)
±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz)
±3.0% + 5LSD (20.00 to 60.00 A, 40 to 100 Hz)
±3.0% + 5LSD (20.00 to 60.00 A, 100 to 400 Hz)

 Precise Low
 Current DC

 

Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD

Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (0.00 to 20.00 A)
±3.0% + 5LSD (20.00 to 60.00 A)

 

 Precise Low
 Current AC+DC

 

 

 

Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD (DC, 50 to 60 Hz)

Range: 0 to 60.00 A
Accuracy:
±2.0% + 7LSD (0.00 to 20.00 A, DC, 40 to 100 Hz)
±2.2% + 7LSD (0.00 to 20.00 A, 100 to 400 Hz)
±3.0% + 7LSD (20.00 to 60.00 A, DC, 40 to 100 Hz)
±3.0% + 7LSD (20.00 to 60.00 A, 100 to 400 Hz)

 

 Frequency

Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (600 A range)

Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (1000 V range)
Range: 40.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (1000 A range)

 

 Resistance

Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD

 

 Capacitance

Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD

 Continuity
 Beeper

ON ≤ 10 Ω
OFF > 250 Ω

 Non-Contact
 V
oltage

10V to 1000V AC, 50/60Hz

 True-RMS

 Low Pass Filter

 Autoranging

 Relative Zero

 MAX/MIN/AVG

 Diode Test

 Data Hold

 Backlight

 Auto Power Off

  300 Series:

                                             
 DC
Microamps 

Range: 0.0 to 2000 µA
Accuracy: ±1.0% + 5LSD

 Temperature*
 (Type K
 thermocouple)
 *Error does not
 include Type-K
 thermocouple errors

 Range: -40.0 to 752°F, -40.0 to 400°C
Accuracy: -40.0 to 14.0°F (±1.0% +3.0°F), >14.0 to 99.9°F (±1.0% +1.5°F)
100 to 752°F (±1.0% +2°F), -40.0 to -10.0°C (±1.0% +1.5°C)
>-10.0 to 99.9°C (±1.0% +0.8°C), 100 to 400°C (±1.0% + 1°C)

 3-Phase and
 Motor Rotation
 Indication

 
Rotation-R for mains supply
Rotation-M for motors

 Inrush Current

 Peak Hold (Crest)

 Work Light

 

 Model                                  

AMP-310

AMP-320

AMP-330

 Display

3-5/6 digits 6000 counts

3-5/6 digits 6000 counts

3-5/6 digits 6000 counts

 Polarity

Automatic

Automatic

Automatic

 Update Rate

 5 per second nominal

 5 per second nominal

5 per second nominal

 Operating
 T
emperature

 
32 to 104°F (0 to 40°C)
        

 
32 to 104°F (0 to 40°C)
                                           

 
14 to 122°F (-10 to 50°C)

 

 Relative Humidity     

 

80% at 30°C, 50% at 40°C

 

80% at 30°C, 50% at 40°C

Non condensing at ≤10°C
90% at 10 to30°C
75% at 30 to 40°C
45% at 40 to 50°C

 Operating Altitude

 0 to 2000 m

 0 to 2000 m

 0 to 2000 m

 Pollution Degree

2

2

2

 Storage
 T
emperature

 -4 to 140°F (-20°C to 60°C),
< 80% RH

 -4 to 140°F (-20°C to 60°C),
< 80% RH

 -4 to 140°F (-20°C to 60°C),
< 80% RH

 
 T
emperature
 Coefficient

 

Nominal 0.15 x (specified
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)

 

Nominal 0.15 x (specified
accuracy)/ °C @ (0°C to 18°C or
28°C to 40°C)

 

Nominal 0.10 x (specified accuracy)/ °C @ (0°C
to 18°C or 28°C to 50°C)

 Battery

Two AAA 1.5 V battery

Two AAA 1.5 V battery

Two AA 1.5 V battery

 EMC

 Meets EN 61326-1:2006

 Meets EN 61326-1:2006

 Meets EN 61326-1:2006

 

 
 Safety Compliance

 

UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032
ed. 3.0 & IEC/EN 61010-031
ed. 1.1

 

UL/IEC/EN 61010-1 ed. 3.0, IEC/
EN 61010-2-033 ed. 1.0, CAN/CSA
C22.2 NO. 61010-1 ed. 3.0, IEC/
EN 61010-2-032 ed. 3.0 & IEC/EN
61010-031 ed. 1.1

 

 UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033
ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0,
IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-
031 ed. 1.1

 Certification

UL (c/us) and CE

UL (c/us) and CE

 UL (c/us) and CE

 Dimensions
 (L x W x H):

8.62 x 3.03 x 1.46 in
(219 x 77 x 37 mm)

8.82 x 3.03 x 1.46 in
(224 x 77 x 37 mm)

 10.16 x 3.70 x 1.73 in
(258 x 94 x 44 mm)

 Weight:

208 g (0.46 lb)

254 g (0.56 lb)

420 g (0.93 lb)

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

 

  • Accurate measurement of current, voltage and frequency on all electrical systems including distorted, non-sinusoidal signals (True-RMS function) and variable frequency drives (low-pass filter).
  • Capacitance measurement for start and run motor capacitors.
  • Resistance and continuity functions to verify quality of electrical connections and to check if motor and transformer coils are working properly.
  • 3-phase Motor and Phase Rotation Tests allow proper connection of a motor to a 3-phase system. Improperly connected motors will spin in a reverse direction, which may destroy the motor or equipment connected to it.
  • Low pass filter allows measurement of current and voltage on variable frequency drives (motors with speed controlled by frequency). Without this feature, the meter would provide erroneous readings when measuring voltage and current.
  • DC Microamps output for measurement of flame sensors. Test the proper operation of the flame sensor safety system in gas appliances. A broken sensor in a gas appliance will prevent the safety valve from opening and the appliance will not work.
  • Inrush current measurement for motor start-up monitoring, allowing users to verify that the motor is receiving the required inrush current to support proper motor start.
  • Products In This Series

    As low as

    Now $377.99

    As low as

    Now $266.99