Amprobe 37XR-A True-RMS Digital Multimeter

SKU
37XR-A
Manufacturer:
Amprobe
Amprobe

Key Features:

  • Backlight, True-rms with component and logic test
  • Inductance to 40 H, frequency to 40 MHz, capacitance to 400 μF, logic to 20 MHz
  • Input warning tone when test leads are in wrong jack
  • 10 Amps AC/DC, fully safety fused
  • Continuity beeper
  • Min/max, average, relative, peak, and data hold
  • Auto power off to save battery life
  • Separate door for easy battery and fuse access
  • Magne-Grip™ Holster with magnetic hanging strap
  • Auto-ranging; display: 4-3/4 digit LCD, 10,000 counts with 41-segment analog bar graph
  • Display Update Rate: 2/sec, nominal
  • Power Battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
  • Operating temperature: 0 °C to 45 °C at < 70 % R.H
Product Options:
$320.99

Secured and trusted checkout with

Amprobe 37XR-A Digital Multimeter offers true-rms measurement along with component and logic testing for troubleshooting electronics at the bench or on the job site.
FEATURE37XR-A
DC Voltage1.000 mV, 10.00 V, 100.0 V, 1000 V
AC Voltage1.000 mV, 10.00 V, 100.0 V, 1000 V
DC Current100.0 µA, 1.000 µA, 10.00 mA, 100.0 mA, 400.0 mA, 10.00 A
AC Current100.0 µA, 1.000 µA, 10.00 mA, 100.0 mA, 400.0 mA, 10.00 A
Resistance1000.0 Ω, 10.000 kΩ, 100.00 kΩ, 1000.0 kΩ, 10.00 MΩ , 40.00 MΩ
Continuity
Diode
VolTect™ Non-Contact Voltage Detection-
Capacitance40.00 nF. 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF
Frequency100.00 Hz, 1.0000 kHz, 10.000 kHz, 100.00 kHz, 1.0000 MHz, 10.000 MHz
Temperature-
Duty cycle0.00 % → 90.0 %
Logic test
Inductance40 H
dBm-13 dBm → + 50 dBm

 

Specifications
DC Voltage ranges:1000 mV, 10 V, 100 V, 1000 V
DC Voltage accuracy:all ranges ± (0.1 % rdg + 5 dgt)
DC Voltage resolution:100 µV
AC Voltage (45 Hz to 2 kHz) True-rms ranges:1000 mV, 10 V, 100 V, 750 V
AC Voltage (45 Hz to 2 kHz) True-rms accuracy:750 V range: 45 to 1 kHz: ± (2.0 % rdg + 10 dgts)
AC Voltage (45 Hz to 2 kHz) True-rms accuracy:All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 10 dgts)
AC Voltage (45 Hz to 2 kHz) True-rms accuracy:All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 10 dgts)
AC Voltage (45 Hz to 2 kHz) True-rms resolution:100 µV
AC coupled:True RMS specified from 5 % to 100 % of range
DC Current ranges:100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A
DC Current accuracy:100 µA range: ± (0.5 % rdg + 10 dgt)
DC Current accuracy:1000 uA to 400 mA ranges: ± (0.5 % rdg + 5 dgts)
DC Current accuracy:10 A range: ± (1.5 % rdg + 10 dgt)
DC Current resolution:0.01 µA
AC Current (45 Hz to 1 kHz) True-rms ranges:100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A
AC Current (45 Hz to 1 kHz) True-rms accuracy:100 µA to 100 mA ranges: ± (1.5 % rdg + 10 dgts)
AC Current (45 Hz to 1 kHz) True-rms accuracy:400 mA range: ± (2.0 % rdg + 10 dgts)
AC Current (45 Hz to 1 kHz) True-rms accuracy:10 A range: ± (2.5 % rdg + 10 dgts)
AC Current (45 Hz to 1 kHz) True-rms resolution:0.01 µA
Resistance ranges:1000 Ω 10 kΩ 100 kΩ 1000 kΩ 10 MΩ 40 MΩ
Resistance accuracy:1000 Ω to 1000 kΩ ranges: ± (0.5 % rdg + 8 dgts)
Resistance accuracy:10 MΩ range: ± (1.0 % rdg + 10 dgts)
Resistance accuracy:40 MΩ range: ± (2.0 % rdg + 10 dgts)
Logic test, logic type:TTL, CMOS