Amprobe 30XR-A Auto Ranging Digital Multimeter with VolTect Non-Contact Voltage Detection

SKU
30XR-A
Manufacturer:
Amprobe
Amprobe

Key Features:

  • Non-contact voltage detector
  • Separate door for easy battery and fuse access
  • Manual ranging; display: 3-1/2 digit LCD, 1999 counts
  • Display update rate: 2.5/sec, nominal
  • Power battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
  • Operating temperature: 0 °C to 45 °C at < 70 % R.H.
  • Storage temperature: -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
  • Low battery indication
  • Over-range indication
  • Min/max and data Hold
Product Options:
$170.99

Secured and trusted checkout with

Amprobe 30XR-A Digital Multimeter offers Voltect non-contact voltage technology built into the 30XR-A along with a full complement of measurement functions.
FEATURE30XR-A
DC Voltage200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
AC Voltage200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
DC Current200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
AC Current200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
Resistance200.0 Ω, 2.000 kΩ, 20.00 kΩ, 200.0 kΩ, 2.000 MΩ, 20.00 MΩ
Continuity
Diode
VolTect™ Non-Contact Voltage Detection
Capacitance-
Frequency-
Temperature-
Duty cycle
Logic test
Inductance
dBm

 

Specifications
DC Voltage ranges:200 mV, 2 V, 20 V, 200 V, 600 V
DC Voltage accuracy:all ranges: ± (1 % rdg + 1 dgt)
DC Voltage resolution:100 µV
DC Voltage input impedance:10 MΩ
AC Voltage (45 Hz to 500 Hz) ranges:200 mV, 2 V, 20 V, 200 V, 600 V
AC Voltage (45 Hz to 500 Hz) accuracy:all ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) resolution:100 µV
AC Voltage (45 Hz to 500 Hz) input impedance:10 MΩ
DC Current ranges:200 µA, 2 mA, 20 mA, 200 mA, 10 A
DC Current accuracy:200 µA to 200 mA ranges: ± (1.5 % rdg + 1 dgt)
DC Current accuracy:10 A range: ± (2.0 % rdg + 3 dgts)
DC Current resolution:0.1 µA
DC Current voltage burden (max):200 µA range: 1 mV/µA
DC Current voltage burden (max):2 mA range: 100 mV/1mA
DC Current voltage burden (max):20 mA range: 13 mV/1 mA
DC Current voltage burden (max):200 mA range: 4.6 mV/1 mA
DC Current voltage burden (max):10A range: 40 mV/1 A
AC Current (45 Hz to 500 Hz) ranges:200 µA, 2 mA, 20 mA, 200 mA, 10 A
AC Current (45 Hz to 500 Hz) accuracy:200 µA to 200 mA ranges: ± (2.0 % rdg + 4 dgts)
AC Current (45 Hz to 500 Hz) accuracy:10A range: ± (2.5 % rdg + 4 dgts)
AC Current resolution:0.1 µA
AC Current voltage burden:See DC Current
Non-contact voltage detector (NCV) AC volts:70 to 600 V ac
Non-contact voltage detector (NCV):Red LED and Audible Indicator



Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account