Ametek Jofra ETC-125A Dry Block Calibrator (-10 to 125 C)

SKU
ETC-125A
Manufacturer:
JOFRA
JOFRA

Key Features:

  • Temperature range from -10 to 125°C (14 to 257°F)
  • Accuracy to ± 0.5°C and Stability to ± 0.3°C
  • Time saving fast cooling and heating times
  • Easy-to-read multi-information display
  • Customizable stability checkmark with countdown timer
  • Set exact temperature desired to a resolution of 0.1°C
  • small lightweight IR calibrator
  • Lightweight and easy to carry
Product Options:
Special Price $4,214.95 Regular Price $4,386.00

Secured and trusted checkout with

The Ametek Jofra ETC Dry Block heats up by up to 100C / 212F per minute and completes a full dual-point test in less than 10 minutes, including stability time; time savings at your fingertips! The ETC- series is designed for field testing of temperature measurement devices. The small size and light weight make it a perfect instrument to verify sensors in difficult to reach places. All JOFRA ETC units have many of the same useful and time saving features offered in the more advanced JOFRA dry-block series.

FUNCTIONAL SPECIFICATIONS

Temperature range @ ambient temp. 23°C / 73°F
ETC-125 A
Maximum ........................................................125°C / 257°F
Minimum @ ambient temp. 0°C / 32°F ........... -18°C / -0°F
Minimum @ ambient temp. 23°C / 73°F ............ -10°C /14°F
Minimum @ ambient temp. 40°C / 104°F ........... 6°C / 43°F
ETC-400 A ......................28 to 400°C / 82 to 752°F@ 23°C
ETC-400 R ......................28 to 400°C / 82 to 752°F@ 23°C
Resolution (user-selectable)
Selectable ............................................................. 1º or 0.1º
Heating time
ETC-125 A
-10 to 23°C / 14 to 73°F .........................................3 minutes
23 to 100°C / 73 to 212°F ....................................11 minutes
100 to 125°C / 212 to 257°F ..................................7 minutes
ETC-400 A / R
28 to 200°C / 82 to 392°F .....................................2 minutes
200 to 400°C / 392 to 752°F .................................3 minutes
Cooling time
ETC-125 A
125 to 100°C / 257 to 212°F ................................. 1 minute
100 to 0°C / 212 to 32°F ......................................17 minutes
0 to -10°C / 32 to 14°F .........................................14 minutes
ETC-400 A
400 to 200°C / 752 to 392°F .................................6 minutes
200 to 50°C / 392 to 122°F..................................15 minutes
ETC-400 R
400 to 200°C / 752 to 392°F .................................9 minutes
200 to 50°C / 392 to 122°F..................................24 minutes
Stability
ETC-125 A ..............................................±0.05°C / +0.09°F
ETC-400 A ............................................. ±0.15°C / +0.27°F
ETC-400 R ...............................................±0.3°C / ±0.54°F
Measured after the stability indicator has been on for 10 minutes.
Measuring time is 30 minutes.
Time to stability (approximate)
All models .............................................................3 minutes
Accuracy
ETC-125 A ............................................... +0.5°C / +0.9°F 1)
ETC-400 A .............................................. +0.5°C / +0.9°F 1)
ETC-400 R .............................................. ±0.5°C / ±0.9°F 2)
ETC-400 R incl. emissivity
.................................... ±0.4% rdg ±1°C / ±0.4% rdg. ±1.8°F
1) Specification when using the internal reference. (Load 4 mm OD reference probe in the center of the insert).
2) Specification when using the internal reference. (Load 3 mm OD reference probe).

Immersion depth
ETC-125 A (insulation included) ................. 110 mm / 4.3 in
ETC-400 A ...................................................105 mm / 4.1 in
Mains specifications
Voltage ETC-125 A ......... Multivoltage 115VAC and 230VAC
........................................ 115V(90-132) and 230V(180-264)
Voltage ETC-400 A/R ....... 115V(90-127) or 230V(180-254)
Frequency ETC-125 A ..........................................47 - 63 Hz
Frequency ETC-400 A/R .....................................45 - 65 Hz
Power consumption (max.) ETC-125 A .......................75 VA
Power consumption (max.) ETC-400 A/R .................350 W

Auto stepping
Programmable ................................................. Up to 9 steps
Dwell time on each step ............................... Programmable
Multi-information display
Stability indicator .......................................Clear checkmark
Countdown timer before stable .............................3 minutes
Temperature .......................SET and READ simultaneously
Alphanumeric messages................................................ Yes
Calibration status icons .................................................. Yes
Training mode (heating/cooling block disabled)
Simulation of all functions .............................................. Yes
Simulating heating and cooling ..... Approx. 100° per minute
Service facilities
Adjustment of the unit from the keypad ......................... Yes
Self explaining guide in display......................................... Yes
Other information: ............................ Display serial number,
.................. software revision level, and last calibration date
Setup facilities
Stability criteria: ......... Extra time before ’’stable indication’’
................................................................................ is shown
Display resolution ............................................. .1° or 1°C/°F
Temperature units ................................................... °C or °F
Slope rate ................................................. 0.1 to 9.9°/minute
Maximum temperature .....................Any value within range

PHYSICAL SPECIFICATIONS
Instrument dimensions
ETC-125 A, ETC-400 A and ETC-400 R
L × W × H: ................172 × 72 × 182 mm / 6.8 × 2.8 × 7.2 in
Instrument weight
ETC-125 A .......................................................1.8 kg / 3.9 lb
ETC-400 A ......................................................1.6 kg / 3.5 lb
ETC-400 R ...................................................... 1.7 kg / 3.7 lb
Shipping (including shipping cargo box)
ETC-125 A: ......................................................3.0 kg / 6.6 lb
ETC-400 A: .................................................... 2.8 kg / 6.2 lb
ETC-400 R ......................................................4.5 kg / 9.9 lb
Size, L × W × H:
ETC-125 A / 400 A: ..............................................................
............................. 345 × 235 × 135 mm / 13.6 × 9.3 × 5.3 in
ETC-400 R ......... 425 x 320 x 165 mm / 16.7 x 12.5 x 6.5 in
Miscellaneous
Serial data interface ................................................. RS232
Operating temperature .....................0 to 40°C / 32 to 104°F
Storage temperature ......................-20 to 50°C / -4 to 122°F
Humidity ..........................................................0 to 90% RH
Protection class ........................................................... IP-10
DNV Marine Approval, Certificate no ......................A-10384