AEMC Model SR704 AC Current Probe (1000A / 1mA/A / Lead)

SKU
2116.30_
Manufacturer:
AEMC
AEMC

Key Features:

  • Measurement range of 1mA to 1200AAC
  • Large jaw opening accommodates conductors up to two 500kcmil
  • Improved ergonomic design and easy operation
  • High content nickel metal core
  • Conforms to EN 61010, 600V CAT III
  • Low phase shift for power measurement
  • Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
Product Options:
$355.00

Secured and trusted checkout with

SR704 is a general purpose 1000AAC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp measured in the jaw. The SR704 has an integral 5 ft (1.5m) lead terminated by shrouded banana plugs. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy and low phase shift and wide frequency response are important.
ELECTRICAL
Nominal Range1000A
Measurement Range1mA to 1200A
Transformation Ratio1000:1
Output Signal1mAAC/AAC
(1AAC @ 1000A)
Accuracy (1000A Range) 
1mA to 100mA≤3% of Reading ± 5μV
0.1 to 1A≤2% of Reading ± 3μV
 1 to 10A<1% of Reading ± 0.2mV
10 to 100A ≤0.5% of Reading
100 to 1200A ≤0.3% of Reading
Phase Shift (1000A Range) 
1 to 10A ≤2°
10 to 100A ≤1°
100 to 1200A ≤0.7°
Overload 1200A for 40 min ON,
20 min OFF
Frequency Range 30Hz to 5kHz;
current derating
above 1kHz using
the formula:
Load Impedance 5Ω max
Working/Common
Mode Voltage
 600Vrms Cat. III
Output Termination 5 ft Lead
MECHANICAL
Operating Temperature-14° to 122°F (-10° to 50°C)
Storage Temperature-4° to 158°F (-20° to 70°C)
Operating Relative
Humidity
0 to 85% @ 35°C
Jaw Opening2.25" (57mm) max
Maximum Conductor Size2.05" (52mm)
Maximum Bus Bar SizeOne 1.95 x 0.19" (50 x 5mm)
Dimensions4.37 x 8.50 x 1.77" (111 x 216 x 45mm)
Weight1.21 lbs (550g)
Polycarbonate MaterialHandles: Polycarbonate + ABS, Gray, UL94 V0. Jaws: Polycarbonate, Red, UL94 V0
SAFETY
ElectricalEN 61010-2-032
UL ApprovalYes – Canada and United States
Double InsulationYes
CE MarkYes

Note: Reference conditions: 23 ± 3°K, 20 to 75% RH, 48 to 65Hz, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample centered. Load impedance 5Ω.
*Diode Protection for open secondary (Output)

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Power quality measuring
  • Large industrial loads
  • Measuring around cable bundles
  • Power load monitoring
  • Waveform analysis