AEMC Model SR604 AC Current Probe (1000A / 1mA/A / Lead)

SKU
2113.44
Manufacturer:
AEMC
AEMC

Key Features:

  • Measurement range of 100mA to 1200AAC
  • Large jaw opening accommodates conductors up to two 500kcmil
  • Improved ergonomic design and easy operation
  • Conforms to EN 61010, 600V CAT III
  • Low phase shift for power measurement
  • Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
Product Options:
$249.00

Secured and trusted checkout with

The SR604 is a general purpose 1000AAC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp measured in the jaw. The SR604 has an integral 5 ft (1.5m) lead terminated shrouded banana plugs. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy and low phase shift is important.
ModelSR604*
ELECTRICAL
Nominal Range1000A
Measurement Range0.1 to 1200A
Transformation Ratio1000: 1
Output Signal1mAac/Aac: (1Aac @ 1000A)

Accuracy (1000A Range)

0.1 to 10A
50A
200A
1000A
1200A

 

≤3% + 0.1A
1.5% of Reading
0.75% of Reading
0.5% of Reading
0.5% of Reading

Phase Shift (1000A Range)

50A
200A
1000A
1200A

 

1.5°
0.75°
0.5°
0.5°

Overload1200A for 40 min ON, 20 min OFF
Frequency Range30Hz to 5kHz; current derating
above 1kHz using the formula:
1000A x 1/F (in kHz)
Load Impedance5Ω max
Working/Common
Mode Voltage
600V Cat. III
Output TerminationLead
MECHANICAL
Operating Temperature-14° to 122°F (-10° to 50°C)
Storage Temperature-4° to 158°F (-20° to 70°C)
Operating Relative
Humidity
0 to 85% @ 35°C
Jaw Opening2.25" (57mm) max
Maximum Conductor Size2.05" (52mm)
Maximum Bus Bar SizeOne 1.95 x 0.19" (50 x 5mm)
Dimensions4.37 x 8.50 x 1.77" (111 x 216 x 45mm)
Weight1.21 lbs (550g)
Polycarbonate MaterialHandles: Polycarbonate + ABS, Gray, UL94 V0. Jaws: Polycarbonate, Red, UL94 V0
SAFETY
ElectricalEN 61010-2-032
UL ApprovalYes – Canada and United States
Double InsulationYes
CE MarkYes

 

Note: Reference conditions: 23 ± 3°K, 20 to 75% RH, 48 to 65Hz, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample centered. Load impedance 0.2Ω @ lead <40mΩ for 250A range.
*Diode Protection for open secondary (Output)