AEMC Model SL206 AC/DC Current Probe (2A-1mV/mA, 80A-10mV/A, Lead) - DISCONTINUED

SKU
1201.45
Manufacturer:
AEMC
AEMC

Key Features:

This Product is DISCONTINUED

  • Low DC and AC measurements
  • 10mA to 80A
  • Unique design for probing in crowded wiring in industrial and automotive environments
  • Hall Effect sensor technology
  • Use with DMMs, voltmeters, and other voltage measuring instruments
Call For Price

Secured and trusted checkout with

AC/DC Current Probe Model SL206 measures low DC or AC from 10mA to 80A. This battery-powered clamp-on probe may be used with digital multimeters, voltmeters, or other voltage-measuring instruments. The probe jaws clamp around the conductor under test, allowing current measurements without breaking the circuit. Hall sensor technology senses the magnetic field produced by the current measured, and generates a millivolt DC or AC output signal. The narrow jaw is designed for optimum use in crowded wiring in industrial and automotive environments.
ELECTRICAL
Nominal Range2A & 80A
Measurement Range10mA to 80ADC; 50mA to 60AAC
Transformation RatioVoltage output
Output Signal2A: 1mV/mA
80A: 10mV/A
Accuracy
(1mV/mA Range)
               10mA to 2AAC/DC


2% of Reading ± 5mA
Phase Shift
(1mV/mA Range)

DC to 65Hz 1°

Accuracy
(10mV/A Range)

50mA to 50ADC



4% of Reading ± 20mA

50mA to 40AAC±4% of Reading ± 20mA
50 to 80ADC±12% of Reading
40 to 60AAC±12% of Reading
Phase Shift
(1mV/mA Range)

DC to 65Hz 1°
Overload120A continuous
Frequency RangeDC to 8kHz
Load Impedance100kW (1mV/mA); 10kW (1V/A)
Working/Common
Mode Voltage
600Vrms
Output Termination5 ft Lead with 4 mm safety banana plug
MECHANICAL
Operating Temperature32° to 122°F (0° to 50°C)
Storage Temperature-22° to 176°F (-30° to 80°C)
Operating Relative
Humidity
10° to 30°C: 85 ± 5% RH (without condensation)
40° to 50°C: 45 ± 5% RH (without condensation)
Maximum Conductor Size0.46" (11.8mm)
Dimensions9.09 x 1.42 x 2.64" (231 x 36 x 67mm)
Weight11.6 oz (330g) with battery
Polycarbonate MaterialHandle: Lexan® 920A, UL94 V2
SAFETY
ElectricalEN 61010-2-32
Double InsulationYes
CE MarkYes

 

Note: Reference conditions: 23°C ± 5°K, 20 to 75% RH, 48 to 65Hz, external magnetic field <40A/m, no external current carrying conductor, test sample centered, load impedance 1Mohm.

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Circuit board testing
  • Motor controllers
  • Automotive circuitry