We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The AEMC 8336 is simple to use and it allows technicians to measure and carry out diagnostics and power quality work on one-, two- or three-phase networks. The Model 8336 has 2 GB of memory that allows users to store up to 50 screen shots, up to 210 captured transients that contain 4 cycles for each active input, and 10,000 alarm events from up to 40 different parameters.
AEMC Model 8336 Options:
AEMC Model 8336 [Part No. 2136.30] PowerPad III (No Current Probes)
AEMC Model 8336 [Part No. 2136.31] PowerPad III wih four 193-24-BK Amplex (6500 Amp) Sensors
AEMC Model 8336 [Part No. 2136.32] PowerPad III with four MN193-BK (100/5 Amp) Probes
MODEL | 8336 |
Input Terminals | 5 voltage / 4 current |
Inputs | 4 voltage / 4 current |
Voltage (TRMS AC+DC) | Phase-to-Phase: 0 to 2000 Phase-to-Neutral : 0 to 1000V |
Voltage Ratio | up to 500kV |
Current (TRMS AC+DC) | MN93: 500mA to 200Aac; MN193: 0.005 to 100Aac SR193 Clamp: 1A to 1000Aac AmpFlex® or MiniFlex® Clamps: 100mA to 10000Aac MR193 Clamp: 1A to 1300Aac/dc SL261 Clamp: 50mA to 100Aac/dc Current Ratio: up to 60kV J93: 50 to 3500Aac, 50 to 5000Adc |
Frequency (Hz) | 40 to 70Hz |
Distribution Systems | 1P 2W, 1P 3W, 2P 2W, 2P 3W, 2P 4W, 3P 3W, 3P 4W, 3p 5W, Split-Phase 2W & 3W, 2 ½ Element & Aron meters |
Power Values | W, VA, var, VAD, PF, DPF, cos ϕ, tan ϕ |
Energy Values | Wh, varh, VAh, VADh |
Harmonics | 1st to 50th, Direction, Sequence; THD: 0 to 50, Phase |
Transients | up to 210 |
Trend Mode | Records up to 41 variables as fast as once per second for one month depending on selected storage rate |
Flicker | Pst & Plt |
Inrush Mode | Yes, >10 min |
Unbalance | Yes |
Record Mode | Yes |
Alarm Mode | 40 types; 10,000 recorded |
Waveform Mode | Calculated: AN (RMS, DC, CF, PK+/-) and FK |
Peak | Yes |
Phasor Display | Automatic |
Data Stoage | 2GB card for trend + 4MB partitioned for snapshot, transients and alarms |
Other Measurements | 256 samples/cycle for trend recording |
Display | Color ¼ VGA TFT screen (320 x 240) diagonal 148mm |
Snapshots | 50 |
Sampling Frequency | 256 samples/cycle for trend recording |
Electrical Safety | IEC 61010, 1000V CAT III / 600V CAT IV |
Protection | IP53 - Non Operating |
Languages | more than 26 |
Communication Interface | USB |
Battery Life | 10 hrs in non - Record Mode with display on; 25 hrs in Record Mode with display off |
Power Supply | 9.6V NiMH rechargeable battery pack (included) External AC supply: 110/230Vac ±10% (50/60Hz) |
Dimensions / Weight | 9.8 x 7.8 x 2.6" (240 x 180 x 55mm) / 4.3 lbs (1.95kg) |
* Registration must take place within 30 days of purchase
- Verification of power distribution circuits
- In-plant troubleshooting of power distribution panels and individual machinery
- Monitor pad mount transformers and phase unbalances
- Determine harmonic problems originating from source or load
- Determine transformer K-Factor
- Energy metering (kVAh, VARh, kWh)