The Digital/Analog Megohmmeter Model 5060 is the latest design in 5000V insulation testers. Features include automatic calculation and presentation of the Dielectric Absorption Ratio (DAR), Polarization Index (PI) and Dielectric Discharge (DD). The Model 5060 displays the test voltage, insulation resistance and the leakage current during the test. Capacitance of the sample and discharge voltage present at the test leads is displayed at the conclusion of the test. This meter is designed with the highest level of built in safety features. The Model 5060 can be operated from an internal rechargeable battery system or from an AC line power. The Model 5060 offers additional functionality in that an RS-232 port provides the ability to configure the unit from a PC and run the test from the PC. Test reports can be generated directly from the instruments to a printer or through the PC using the DataView® graphing and analysis software.
MODELS | 5050 | 5060 |
INSULATION TESTS | ||
Test Voltage 500V |
30kΩ to 2000GΩ (2TΩ) | |
User Selectable Test Voltage | Programmable: 40 to 1000V: 10V increments; 1000 to 5100V: 100V increments | |
Automatic Step Voltage | – | |
Accuracy 1kΩ to 40GΩ |
±5% of Reading ± 3cts
| |
Voltage Test/Safety Check | 2500Vac/4000Vdc | |
Voltage Warning Indicator | Yes >25V | |
Test Inhibition* | Yes — adjustable from 25 to 1000V depending on test voltage range in use | |
Smooth Function (user selectable) | Digital filtering stabilizes display readings | |
COMMUNICATION | ||
Storage of Readings over Time R(t) | 4kB memory | 128kB memory |
Storage of Test Results | 20 Readings | Stores over 1500 test results |
Communication Port | – | Serial and RS-232 to USB adapter (included) |
PC Software/Report Generation | No | DataView® (included) |
ELECTRICAL | ||
Power Source | One 9.6V NiMH battery pack (included) Line power: 85 to 256V (50/60Hz) |
*Inhibit voltage is selectable at 3, 10 or 20% of test voltage