AEMC’s 205 True RMS Clamp-On Meter not only measures AC/DC amps and volts, continuity, resistance and frequency, but it performs diode checks and has the capability to measure Power, Power Factor, THD and phase rotation. Compare new measurements to reference values with the Delta Relative Function and keep track of the high and low values with the MIN/MAX function. Even more, the 205 also records peak + and peak-values.
The Clamp-On meter is constructed to face the most demanding work environments. It has the durability to tolerate both dust and water spray with its IP54 rating and features a 600V CAT IV safety rating.
MODELS | 401/601 TRMS | 203/403/603 TRMS | 205/405/605 TRMS |
ELECTRICAL | |||
Current AC (rms) | 1000/2000A | 600/1000/2000A | 600/1000/2000A |
Current DC | – | 900/1500/3000A | 900/1500/3000A |
Current AC+DC | – | – | 900/1500/3000A |
Voltage AC (rms) | 1000/1000V | 1000/1000/1000V | 1000/1000/1000V |
Voltage DC | 1000/1000V | 100/1000/1000V | 1000/1000/1000V |
Voltage AC+DC | – | – | 1000/1000/1000V |
Ohms | 100/100kΩ | 60/100/100kΩ | 60/100/100kΩ |
Continuity (Buzzer) | Yes (< 40Ω) | Yes (< 40Ω) | Yes (< 40Ω) |
Diode Test | Yes | Yes | Yes |
Total Harmonic Distortion | – | – | Yes |
Single- and 3-Phase Real Power (AC, DC, AC/DC)* |
– |
– | 600/1000/2000kW 3000/6000kW |
Single- and 3-Phase Reactive Power (AC, DC, AC/DC)* |
– |
– | 600/1000/2000kvar 3000/6000kvar |
Single- and 3-Phase Apparent Power (AC, DC, AC/DC)* |
– |
– | 600/1000/2000kVA 3000/6000kVA |
Temperature (int., ext., C°, F°) | Yes | Yes | – |
Voltage Frequency (Hz) | 20kHz | 20kHz | 20kHz |
Current Frequency (Hz) | 2kHz | 3/2/2kHz | 2kHz |
Power Function (W, var, VA) | – | – | Yes |
Power Factor | – | – | Yes |
THD-r/THD-f | – | – | Yes |
Adapter (AC/DC) | – | 0 to 10V | – |
Phase Rotation | – | – | Yes (2 wire) |
Auto AC/DC | Yes (V) | Yes (V & A) | Yes (V & A) |
Auto Power OFF | Yes | Yes | Yes |
Hold Button | Yes | Yes | Yes |
Backlight Button | Yes | Yes | Yes |
Min/Max Button | Yes | Yes | Yes |
True InRush ® Function | Yes | Yes | Yes |
Relative Function | – | Yes | Yes |
Peak ± Function | – | – | Yes |
Hz Button | Yes | Yes | Yes |
*3-phase measurements assume balanced load
- Electrical maintenance and power distribution
- Safety lighting system maintenance
- Automotive test troubleshooting
- AC or DC motor testing
- Power plant troubleshooting
- Commercial, industrial residential & HVAC troubleshooting
- Power panel, junction box and battery bank measuring
- Electrical testing and troubleshooting on non-linear loads, such as adjustable speed drives and computers