We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Accuenergy Acuvim IIBN energy meter is equipped with a built-in BACnet communication module specifically crafted to monitor and collect real-time revenue-grade electrical data for building control and automation applications. The meter shows multiple energy parameters such as voltage, ampere, power factor, harmonic distortions, energy and demand data making it perfect for three-phase, two-phase and single-phase systems to track energy consumption and trends.
METERING | ||||
Parameters | Accuracy | Resolution | Range | |
Voltage | 0.2% | 0.1V | 10V~1000kV | |
Current | 0.2% | 0.1mA | 5mA~50000A | |
Power | 0.2% | 1W | -9999MW~9999MW | |
Reactive Power | 0.2% | 1var | -9999Mvar~9999Mvar | |
Apparent Power | 0.2% | 1VA | 0~9999MVA | |
Power Demand | 0.2% | 1W | -9999MW~9999MW | |
Reactive Power Demand | 0.2% | 1var | -9999Mvar~9999Mvar | |
Apparent Power Demand | 0.2% | 1VA | 0~9999MVA | |
Power Factor | 0.2% | 0.001 | -1.000~1.000 | |
Frequency | 0.02% | 0.01Hz | 45.00~65.00Hz (50 or 60Hz type) 300.00Hz~500.00Hz (400Hz type) | |
Energy | Primary | 0.2% | 0.1kWh | 0-99999999.9kWh |
Secondary | 0.2% | 0.001kWh | 0-999999.999kWh | |
Reactive Energy | Primary | 0.2% | 0.1kvarh | 0-99999999.9kvarh |
Secondary | 0.2% | 0.001kvarh | 0-999999.999kvarh | |
Apparent Energy | Primary | 0.2% | 0.1kVAh | 0-99999999.9kVAh |
Secondary | 0.2% | 0.001kVAh | 0-999999.999kVAh |
INPUT | |
Current Inputs (Each Channel) | |
Nominal Current | ①5A, ②1A, ③1A(333mV), ④1A(100mV Rope-CT), ⑤1A(80mA/100mA/200mA) |
Metering Range | ①0~10A, ②0~2A, ③0~1.2A,④0~1.2A, ⑤0~1.2A |
Pickup Current | ①5mA, ②1mA, ③5mA, ④5mA, ⑤5mA |
Withstand | 20Arms Continuous, 0.1% of Nominal 100Arms for 1 second, Non-Recurring |
Burden | 0.05VA (Typical) @ 5Arms |
Accuracy | 0.2% Full Scale |
Voltage Inputs (Each Channel) | |
Nominal Full Scale | 400Vac L-N, 690Vac L-L (+20%) |
Withstand | 1500Vac Continuous 2500Vac, 50/60Hz for 1 Minute |
Input Impedance | 2Mohm per Phase |
Metering Frequency | 45Hz~65Hz, 300Hz ~ 500Hz |
Pickup Voltage | 10Vac |
Accuracy | 0.2% Full Scale |
Energy Accuracy | |
Active | Class 0.2s (According to IEC 62053-22) Class 0.2s (According to ANSI C12.20) |
Reactive | Class 2 (According to IEC 62053-23) |
Harmonic Resolution | |
63rd Harmonic (50Hz or 60Hz type) 15th Harmonic (400Hz type) |
STANDARD COMPLIANCE | |
Measurement Standard | IEC 62053-22; ANSI C12.20 |
Environmental Standard | IEC 60068-2 |
Safety Standard | IEC 61010-1, UL 61010-1, IEC 61557-12 |
EMC Standard | IEC 61000-4/-2-3-4-5-6-8-11, CISPR 22, IEC 61000-3-2, IEC 61000-6-2/4 |
Outlines Standard | DIN 43700, ANSI C39.1 |
CONTROL POWER | |
Universal | AC or DC |
AC/DC Control Power | |
Operating Range | 100~415Vac, 50/60Hz; 100~300Vdc |
Burden | 5W |
Frequency | 50/60Hz |
Withstand | 3250Vac, 50/60Hz for 1 minute |
Installation Category III (Distribution) |
OPERATING ENVIRONMENT | |
Operation Temperature | - 25°C to 70°C |
Storage Temperature | - 40°C to 85°C |
Relative Humidity | 5% to 95% Non-Condensing |
Write Your Own Review
- • Tenant Sub Metering
- • Data Center Monitoring
- • Building Automation
- • Industrial Facility Metering
- • Commercial Building Metering