We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Preform remote and on-site monitoring of relative humidity with Newport’s HX92B Humidity Transmitter. The HX92B allows users to select a voltage or 2-wire current output configuration for the utmost flexibility. With the current output configuration, the transmitter can be set at a remote location almost any distance from the actual measuring instrument.
The HX92B is equipped with a linearized output and compensated temperature. More still, a stainless steel mesh type filter, which can be effortlessly removed for cleaning, provides added protection for the digital sensor. The polycarbonate enclosure defends the unit to NEMA 13 (IP54) standards while still allowing easy access to the mounting screws inside.
Input Power
4 to 20mA: 9 to 30Vdc @ 50mA
0 to 1V: 9 to 30Vdc @ 50mA
0 to 5V: 9 to 30Vdc @ 50mA
0 to 10V: 12 to 30Vdc @ 50mA
Measuring Range: 0 to 100% RH
Accuracy: ±2.5% from 20 to 80% RH; ±3.5% from 5 to 20% and 80 to 95% RH; ±4% from 0 to 5% and 95 to 100% RH
Output:
HX92BC: 4 to 20 mA for 0 to 100% RH
HX92BV0: 0 to 1 Vdc for 0 to 100% RH
HX92BV1: 0 to 5 Vdc for 0 to 100% RH
HX92BV2: 0 to 10 Vdc for 0 to 100% RH
Relative Humidity Temperature Compensation: -30 to 75°C (-22 to 167°F)
Relative Humidity Response Time: 8 second typical
Repeatability: ±0.1% RH
Sample Rate: 1 sample every 4 seconds
Housing: Gray polycarbonate, NEMA 13 (IP54)
Connections: Liquid-tight nylon with neoprene gland, for 2.29 to 6.73 (0.09 to 0.265")diameter cable; internal 5 position terminal block accepts 14 to 22 gauge wire
Dimensions:
HX92B(*) (without Probe): 65 L x 50 W x 34.8 D mm (2.56 x 1.97 x 1.37")
TP-SP (Short Probe): 16 dia. x 71.88 L mm (0.63 x 2.83")
Weight:
HX92B(*): 124 g (4.4 oz)
HX92B(*)-D: 132 g (4.7 oz)
HX92B(*)-RP1: 230 g (8.1 oz)