Newport HX92B Humidity Transmitter

SKU
HX92B
Manufacturer:
Newport
Newport

Key Features:

  • 4 to 20 mA, 0 to 1 Vdc, 0 to 5 Vdc or 0 to 10 Vdc Outputs
  • Accurate to ±2.5% (20 to 80% Relative Humidity)
  • Rugged Industrial Splashproof Enclosure NEMA 13 (IP54)
  • Duct Mount Kit Included with Duct Mount and Remote Probe Models
  • Field Replaceable Sensor Probe (Except for Duct Mount Model)
Product Options:
Call For Price

Secured and trusted checkout with

Preform remote and on-site monitoring of relative humidity with Newport’s HX92B Humidity Transmitter. The HX92B allows users to select a voltage or 2-wire current output configuration for the utmost flexibility. With the current output configuration, the transmitter can be set at a remote location almost any distance from the actual measuring instrument.

The HX92B is equipped with a linearized output and compensated temperature. More still, a stainless steel mesh type filter, which can be effortlessly removed for cleaning, provides added protection for the digital sensor. The polycarbonate enclosure defends the unit to NEMA 13 (IP54) standards while still allowing easy access to the mounting screws inside.

Input Power
    4 to 20mA: 9 to 30Vdc @ 50mA
    0 to 1V: 9 to 30Vdc @ 50mA
    0 to 5V: 9 to 30Vdc @ 50mA
    0 to 10V: 12 to 30Vdc @ 50mA
Measuring Range: 0 to 100% RH
Accuracy: ±2.5% from 20 to 80% RH; ±3.5% from 5 to 20% and 80 to 95% RH; ±4% from 0 to 5% and 95 to 100% RH
Output:
    HX92BC: 4 to 20 mA for 0 to 100% RH
    HX92BV0: 0 to 1 Vdc for 0 to 100% RH
    HX92BV1: 0 to 5 Vdc for 0 to 100% RH
    HX92BV2: 0 to 10 Vdc for 0 to 100% RH
Relative Humidity Temperature Compensation: -30 to 75°C (-22 to 167°F)
Relative Humidity Response Time: 8 second typical
Repeatability: ±0.1% RH
Sample Rate: 1 sample every 4 seconds
Housing: Gray polycarbonate, NEMA 13 (IP54)
Connections: Liquid-tight nylon with neoprene gland, for 2.29 to 6.73 (0.09 to 0.265")diameter cable; internal 5 position terminal block accepts 14 to 22 gauge wire
Dimensions:
    HX92B(*) (without Probe): 65 L x 50 W x 34.8 D mm (2.56 x 1.97 x 1.37")
    TP-SP (Short Probe): 16 dia. x 71.88 L mm (0.63 x 2.83")
Weight:
    HX92B(*): 124 g (4.4 oz)
    HX92B(*)-D: 132 g (4.7 oz)
    HX92B(*)-RP1: 230 g (8.1 oz)

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account