Amprobe TMA5 Mini Vane Anemometer

SKU
TMA5
Manufacturer:
Amprobe
Amprobe

Key Features:

  • Pocket size, compact design
  • Measures: air velocity, temperature, humidity, dew point, wet bulb, wind-chill and ambient temperature
  • Selectable wind units: KNT (Knot), BF (Beaufort), ft/m (feet per minute), M/h (mile per hour), m/s (meter per second), km/h (kilometer per hour)
  • Selectable temperature units °C or °F
  • Max wind speed display
  • Quick measurement response
  • External temperature probe
  • Easy, two-button operation
  • Data hold
  • Auto power off with disable feature
  • Low battery indication
  • Ergonomic design with a wrist strap
Product Options:
$247.99

Secured and trusted checkout with

The Amprobe TMA5 Mini Vane Anemometer is a compact, pocket-sized tool for indoor air quality and HVAC/R technicians measuring heating, ventilation, air-conditioning, refrigeration wind flow and temperature in residential, commercial and industrial air conditioning systems.

FeaturesTMA5
Wind speed range0.5 → 44.7 mph, 60 → 3937 ft/m, 0.4 → 38.8 knt, 1.1 → 20.0 m/s, 0.7 → 72.0 kmh, 1 → 8 BF
Air temperature range32 °F → 122 °F (0 °C → 50 °C)
External temperature range-4 °F → 158 °F (-20 °C → 70 °C)
Air RH% range5 % → 95 % RH
Wind speed responseAveraging every 2 seconds
Temperature response time60 seconds (typical)
Air RH% response time60 seconds (typical)
Wind-chill display
Dew point temperature
Wet bulb temperature

 

Specifications
Wind speed range:0.5 - 44.7 MPH, 60 - 3937 FT/M, 0.4-38.8KNT, 1.1-20.0 M/S, 0.7-72.0KMH, 1-8 BF
Wind speed accuracy:+/-5% of reading or last significant digit (whichever is greater)
Air temperature range:0°C to 50°C (32°F to 122°F)
Air temperature resolution:0.1°C/°F
Air temperature accuracy:+/-1°C (+/- 30.2°F to 33.8°F)
External temperature range:-20°C to 70°C (-4°F to 158°F)
External temperature resolution:0.1°C/°F
External temperature accuracy:+/-0.6°C (+/- 31°F to 33.1°F) (-20°C to 50°C / -4°F to 122°F), other ranges +/-1.2°C (29.8°F to 34.2°F)
Air RH% range:5%RH to 95% RH
Air RH% resolution:0.1% RH
Air RH% accuracy:+/-3.5% RH (at 25C, 10 – 90% RH, other ranges +/- 5% RH)
Wind speed response:averaging every 2 seconds
Temperature response time:60 seconds (typical)
Air RH% response time:60 seconds (typical)
LCD update:Every second
Wind-chill display:Yes
Dew point temperature:Yes
Wet bulb temperature:Yes
LCD size:21(H)x 34(W) mm
Battery:CR2032
Write Your Own Review