Companion to your scope or power quality meter to measure up to 400 A AC.
Specifications
Specifications
Nominal current range
40 A Range
0.5 A to 40 A
400 A Range
5 A to 400 A
Basic accuracy
40 A Range
2% + 0.015 A (45-400 Hz)
400 A Range
2% + 0.04 A (45-400 Hz)
Phase shift
40 A Range
0.5 to 1 A
Unspecified
1 A to 5 A
4°
5 A to 10 A
3°
10 A to 20 A
3°
20 A to 40 A
2°
40 A to 400 A
NA
400 A Range
0.5 to 1 A
NA
1 A to 5 A
NA
5 A to 10 A
Unspecified
10 A to 20 A
2°
20 A to 40 A
2°
40 A to 400 A
1.5°
Typical bandwidth
40 A Range
5 Hz - 10 kHz
400 A Range
5 Hz - 10 kHz
Output level(s)
40 A Range
10 mV/A
400 A Range
1 mV/A
Crest factor
40 A Range
≤ 3
400 A Range
≤ 3 to 300 A
≤ 2.5 to 400 A
Safety Specifications
Safety
CAT IV, 600 V, CAT III, 1000 V
Maximum non-destructive current
1000 V AC
Mechanical and General Specifications
Warranty
1 year
Maximum conductor size
32 mm (1.25 inches)
Output cable length
2.5 m (8.2 ft)
BNC adapter
Yes
Dimensions
150 x 70 x 30 mm
Weight
114 g
The store will not work correctly when cookies are disabled.