Companion to your scope or power quality meter to measure up to 400 A AC.
Specifications | ||
Nominal current range | 40 A Range | 0.5 A to 40 A |
400 A Range | 5 A to 400 A | |
Basic accuracy | 40 A Range | 2% + 0.015 A (45-400 Hz) |
400 A Range | 2% + 0.04 A (45-400 Hz) | |
Phase shift | 40 A Range | |
0.5 to 1 A | Unspecified | |
1 A to 5 A | 4° | |
5 A to 10 A | 3° | |
10 A to 20 A | 3° | |
20 A to 40 A | 2° | |
40 A to 400 A | NA | |
400 A Range | ||
0.5 to 1 A | NA | |
1 A to 5 A | NA | |
5 A to 10 A | Unspecified | |
10 A to 20 A | 2° | |
20 A to 40 A | 2° | |
40 A to 400 A | 1.5° | |
Typical bandwidth | 40 A Range | 5 Hz - 10 kHz |
400 A Range | 5 Hz - 10 kHz | |
Output level(s) | 40 A Range | 10 mV/A |
400 A Range | 1 mV/A | |
Crest factor | 40 A Range | ≤ 3 |
400 A Range | ≤ 3 to 300 A | |
≤ 2.5 to 400 A | ||
Safety Specifications | ||
Safety | CAT IV, 600 V, CAT III, 1000 V | |
Maximum non-destructive current | 1000 V AC | |
Mechanical and General Specifications | ||
Warranty | 1 year | |
Maximum conductor size | 32 mm (1.25 inches) | |
Output cable length | 2.5 m (8.2 ft) | |
BNC adapter | Yes | |
Dimensions | 150 x 70 x 30 mm | |
Weight | 114 g |