Fluke Ti105 Infrared Camera Detailed Specifications | IR resolution (FPA size) | 160 x 120 FPA Uncooled Microbolometer | Spectral band | 7.5 µm to 14 µm (long wave) | Capture or refresh rate | 30 Hz version | NETD (thermal sensitivity) | ≤ 0.10°C at 30°C target temp (100 mK) | FOV (field of view) | 22.5° H x 31° V | IFOV (spatial resolution) | 3.39 mRad | Temperature measurement range (not calibrated below -10°C) | -20°C to + 250°C (-4°F to 482°F) | Temperature measurement accuracy | ±2°C or 2% (at 25°C nominal, whichever is greater) | Focus mechanism | Focus-free 1.2 m (4 ft) and beyond | IR Fusion® technology | PIP (1.2 m (4 ft) to 4.6 m (15 ft)), full IR, full visible | Fluke Connect compatibility | Yes (where available) | Color alarms | - | Standard palettes | Blue-red, ironbow, grayscale and amber | Ultra Contrast™ palettes | - | Hot/cold markers | - | User definable spot markers | In SmartView® only | Centerpoint | Yes | Centerbox (MIN/AVG/MAX) | - | Level and span control | Manual and auto | Minimum span in auto mode | 5°C | Minimum span in manual mode | 2.5°C | Minimum IR focus distance | 122 cm (48 in) | Weight | 0.726 kg (1.6 lb) | Size | 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) | LCD display | 3.5 inch diagonal (portrait format) | Visible camera | 2 megapixel industrial-grade | Minimum parallax | ~122 cm (48 in) | IR-PhotoNotes™ annotation system | - | Laser pointer | Yes | Torch | Yes | Electronic (cardinal) compass | - | Emissivity correction | Yes | Transmission correction | - | Background (reflected) compensation | Yes | Voice annotation (audio) | - | Multi-mode video output | - | Multi-mode video recording (standard AVI with MPEG encoding) | - | Multi-mode video recording (radiometric .IS3) | - | Memory review | Thumbnail review | Battery (field-replaceable, rechargeable) | One | Battery life | 4+ hours (each)* | External battery charging base | Optional (accessory) | Charging power supply | Yes | Drop test | 2 meter (6.5 feet) | Ingress protection (IP) rating (IEC 60529) | IP 54 | Recommended calibration cycle | Two-years | Multifunction card reader | - | Memory storage | 2 GB SD memory card | Direct download capability | Mini USB download direct to PC | Operating temperature range | -10°C to +50°C (14°F to 122°F) | Storage temperature range | -20°C to +50°C (-4°F to 122°F) | Operating humidity | Operating and storage 10% to 95%, non-condensing | Vibration and shock | 2G, IEC 68-2-26 and 25G, IEC 68-2-29 | Safety standards | IEC 61010-1: Cat None, Pollution Degree 2 | C Tick | IEC/EN 61326-1 | EMI, RFI, EMC | EN61326-1; FCC Part 5 | User manuals | Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian | Standard warranty period | Two-years | Extended warranty and service plans | Yes | *Assumes 50% brightness of LCD |
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ± ([% of Reading ] + [ Number of least significant digits ]). Fluke 3000 FC Series Wireless Multimeter AC Voltage | Range (1) / resolution | | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | Accuracy (2) (3) (4) | 45 Hz to 500 Hz | 1.0% + 3 | 500 Hz to 1 kHz | 2.0% + 3 | (1) All AC voltage ranges are specified from 1% of range to 100% of range. (2) Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. (3) For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. (4) Do not exceed 107 V-Hz. | DC Voltage, Continuity, Resistance, Diode Test and Capacitance | mV | Range / resolution | 600.0 mV / 0.1 mV | Accuracy | 0.09% + 2 | V | Range / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | Accuracy | 0.09% + 2 0.15% + 2 | ))) | Range / resolution | 600 Ω / 1 Ω | Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | Ω | Range / resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ | Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 | Diode test | Range / resolution | 2.000 V / 0.001 V | Accuracy | 1% + 2 | µF | Range / resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF (1) / 1 μF | Accuracy | 1.2% + 2 10% typical | (1) In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | AC and DC Current | mA AC (45 Hz to 1 kHz) | Range (1) / resolution | 60.00 mA / 0.01 mA 400.0 mA (3)/ 0.1 mA | Accuracy | 1.5% + 3 | mA DC (2) | Range (1) / resolution | 60.00 mA / 0.01 mA 400.0 mA3/ 0.1 mA | Accuracy | 0.5% + 3 | (1) All AC current ranges are specified from 5% of range to 100% of range. (2) Input burden voltage (typical): 400 mA input 2 mV/mA. (3) 400.0 mA accuracy specified up to 600 mA overload. | Frequency | Range / resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | Accuracy (1) | 0.1% + 1 | (1) Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | Input Characteristics | | Overload protection | 1100 Vrms | Input impedance (nominal) | > 10 MΩ < 100 pF | Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | | Overload protection | 1100 Vrms | Input impedance (nominal) | > 10 MΩ < 100 pF | Common mode rejection ratio (1 kΩ unbalance) | > 60 dB, DC to 60 Hz | Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | | Overload protection | 1100 Vrms | Input impedance (nominal) | > 10 MΩ < 100 pF | Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | Open Circuit Test Voltage | | Overload protection | 1100 Vrms | Input impedance (nominal) | < 2.7 VDC | Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | < 0.7 VDC < 0.9 VDC | Typical short circuit current | < 350 mA | | Overload protection | 1100 Vrms | Input impedance (nominal) | < 2.7 VDC | Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | 2.000 VDC | Typical short circuit current | < 1.1 mA | mA Function | Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | MIN/MAX Recording Accuracy | DC functions | ±12 counts for changes > 350 mS in duration. | AC functions | ±40 counts for changes > 900 mS in duration. | General Specifications | Maximum voltage between any terminal and earth ground | 1000 VDC or AC rms | Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | Display (LCD) | Update rate | 4/sec | Volts, amps, ohms | 6000 counts | Frequency | 10,000 counts | Capacitance | 1,000 counts | Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | Battery life | 250 hours minimum | RF communications | 2.4 GHZ ISM Band | RF communication range | Open air, unobstructed | Up to 20m | Obstructed, sheetrock wall | Up to 6.5m | Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5m | Temperature | Operating | -10°C to 50°C | Storage | -40°C to 60°C | Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) | Altitude | Operating | 2,000 m | Storage | 12,000 m | Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE | Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 | Certifications | CSA, FCC, CE | Ingress Protection (IP) rating | IP54 | Pollution Degree | 2 | Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | Weight | 340 g (12 oz) | Warranty | Three years | Not compatible with Fluke CNX test tools |
Fluke a3001 FC Wireless iFlex AC Current Module Specifications | Range | 0.5 A to 2500 A AC | Resolution | 0.1 A | Accuracy | 3% ± 5 digits (5 Hz to 500 Hz) | Crest factor (50 Hz / 60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 | LCD w/backlight | 3½ digits | Log rate/interval | 1 sec minimum/adjustable by PC or front panel | Battery type | 2 AA, NEDA 15 A, IEC LR6 | Battery life | 400 hours | Memory | Record up to 65,000 readings | RF communications | 2.4 GHZ ISM Band | RF communication range | Open air, unobstructed | Up to 20 m | Obstructed, sheetrock wall | Up to 6.5 m | Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | Operating temperature | -10°C to +50°C | Storage temperature | -40°C to +60°C | Temperature coefficient | Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C | Altitude | Operating | 2,000 m | Storage | 12,000 m | EMC | EN 61326-1:2006 | Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition | Safety rating | CAT IV 600 V, CAT III 1000 V | Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | Ingress Protection (IP) rating | IP42 | Pollution Degree | 2 | Jaw opening | 25.4 cm (10 in) coil | Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | Weight | .22 kg (8 oz) | Warranty | Three years | Not compatible with Fluke CNX test tools |
|