Identify issues before they become expensive failures with Fluke’s Ti105 a3001 FC iFlex Kit. The kit is comprised of the Fluke Ti105 Infrared Camera, the Fluke 3000 FC Wireless Multimeter and the Fluke a3001 FC iFlex AC Wireless Current Module. Now, users can connect the a3001 to the desired test point and see the results up to distances of 20 meters away on the Fluke 3000 FC DMMM. The a3001 assists in measurements around confined or award spaces and sizes making wire access effortless, while the Ti105 is equipped with IR Fusion Technology for precision documentation. Even more, all measurement data can be uploaded to the Cloud by a smart phone for later analysis and collaboration.
Fluke Connect® with ShareLive™ video call is the most comprehensive software and wireless test tool family that keeps you in contact with your entire team without leaving the field. The Fluke Connect family offers the largest system of connected test tools in the world. The software is compatible with the HTC One and One M8 running Android 4.4.x or higher, LG G3 and Nexus 5 running Android 4.4.x or higher, Samsung Galaxy S4 running Android 4.3.x or higher, Samsung Galaxy S5 running Android 4.4.x or higher. It also works with the iPhone models 4S and higher running iOS 8.0 or higher, iPad Air and iPad Mini (2nd generation) in an iPhone frame on iPad and iPod Touch (5th generation) and comes with over 30 different Fluke products. Please see our Fluke Connect category for the complete collection of Fluke Connect Products. Take me to Fluke Connect (Click Here).
- • Share images in real-time across teams with Fluke Connect
- • Save time by creating and emailing reports from the jobsite
- • Capture multiple measurements all in one report
- • WiFi upload and free storage with Fluke Cloud™
- • Store thousands of images with internal 4 GB memory and external slot
Fluke Ti105 Infrared Camera
Detailed Specifications | |
IR resolution (FPA size) | 160 x 120 FPA Uncooled Microbolometer |
Spectral band | 7.5 µm to 14 µm (long wave) |
Capture or refresh rate | 30 Hz version |
NETD (thermal sensitivity) | ≤ 0.10°C at 30°C target temp (100 mK) |
FOV (field of view) | 22.5° H x 31° V |
IFOV (spatial resolution) | 3.39 mRad |
Temperature measurement range (not calibrated below -10°C) | -20°C to + 250°C (-4°F to 482°F) |
Temperature measurement accuracy | ±2°C or 2% (at 25°C nominal, whichever is greater) |
Focus mechanism | Focus-free 1.2 m (4 ft) and beyond |
IR Fusion® technology | PIP (1.2 m (4 ft) to 4.6 m (15 ft)), full IR, full visible |
Fluke Connect compatibility | Yes (where available) |
Color alarms | - |
Standard palettes | Blue-red, ironbow, grayscale and amber |
Ultra Contrast™ palettes | - |
Hot/cold markers | - |
User definable spot markers | In SmartView® only |
Centerpoint | Yes |
Centerbox (MIN/AVG/MAX) | - |
Level and span control | Manual and auto |
Minimum span in auto mode | 5°C |
Minimum span in manual mode | 2.5°C |
Minimum IR focus distance | 122 cm (48 in) |
Weight | 0.726 kg (1.6 lb) |
Size | 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) |
LCD display | 3.5 inch diagonal (portrait format) |
Visible camera | 2 megapixel industrial-grade |
Minimum parallax | ~122 cm (48 in) |
IR-PhotoNotes™ annotation system | - |
Laser pointer | Yes |
Torch | Yes |
Electronic (cardinal) compass | - |
Emissivity correction | Yes |
Transmission correction | - |
Background (reflected) compensation | Yes |
Voice annotation (audio) | - |
Multi-mode video output | - |
Multi-mode video recording (standard AVI with MPEG encoding) | - |
Multi-mode video recording (radiometric .IS3) | - |
Memory review | Thumbnail review |
Battery (field-replaceable, rechargeable) | One |
Battery life | 4+ hours (each)* |
External battery charging base | Optional (accessory) |
Charging power supply | Yes |
Drop test | 2 meter (6.5 feet) |
Ingress protection (IP) rating (IEC 60529) | IP 54 |
Recommended calibration cycle | Two-years |
Multifunction card reader | - |
Memory storage | 2 GB SD memory card |
Direct download capability | Mini USB download direct to PC |
Operating temperature range | -10°C to +50°C (14°F to 122°F) |
Storage temperature range | -20°C to +50°C (-4°F to 122°F) |
Operating humidity | Operating and storage 10% to 95%, non-condensing |
Vibration and shock | 2G, IEC 68-2-26 and 25G, IEC 68-2-29 |
Safety standards | IEC 61010-1: Cat None, Pollution Degree 2 |
C Tick | IEC/EN 61326-1 |
EMI, RFI, EMC | EN61326-1; FCC Part 5 |
User manuals | Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian |
Standard warranty period | Two-years |
Extended warranty and service plans | Yes |
*Assumes 50% brightness of LCD |
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ± ([% of Reading ] + [ Number of least significant digits ]).
Fluke 3000 FC Series Wireless Multimeter
AC Voltage | |||
Range (1) / resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | ||
Accuracy (2) (3) (4) | 45 Hz to 500 Hz | 1.0% + 3 | |
500 Hz to 1 kHz | 2.0% + 3 | ||
(1) All AC voltage ranges are specified from 1% of range to 100% of range. (2) Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. (3) For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. (4) Do not exceed 107 V-Hz. | |||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||
mV | Range / resolution | 600.0 mV / 0.1 mV | |
Accuracy | 0.09% + 2 | ||
V | Range / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | |
Accuracy | 0.09% + 2 0.15% + 2 | ||
))) | Range / resolution | 600 Ω / 1 Ω | |
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | ||
Ω | Range / resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ | |
Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 | ||
Diode test | Range / resolution | 2.000 V / 0.001 V | |
Accuracy | 1% + 2 | ||
µF | Range / resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF (1) / 1 μF | |
Accuracy | 1.2% + 2 10% typical | ||
(1) In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | |||
AC and DC Current | |||
mA AC (45 Hz to 1 kHz) | Range (1) / resolution | 60.00 mA / 0.01 mA 400.0 mA (3)/ 0.1 mA | |
Accuracy | 1.5% + 3 | ||
mA DC (2) | Range (1) / resolution | 60.00 mA / 0.01 mA 400.0 mA3/ 0.1 mA | |
Accuracy | 0.5% + 3 | ||
(1) All AC current ranges are specified from 5% of range to 100% of range. (2) Input burden voltage (typical): 400 mA input 2 mV/mA. (3) 400.0 mA accuracy specified up to 600 mA overload. | |||
Frequency | |||
Range / resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | ||
Accuracy (1) | 0.1% + 1 | ||
(1) Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | |||
Input Characteristics | |||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 60 dB, DC to 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | > 10 MΩ < 100 pF | ||
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | ||
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | ||
Open Circuit Test Voltage | |||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | < 2.7 VDC | ||
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | < 0.7 VDC < 0.9 VDC | ||
Typical short circuit current | < 350 mA | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal) | < 2.7 VDC | ||
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | 2.000 VDC | ||
Typical short circuit current | < 1.1 mA | ||
mA Function | |||
Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | ||
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||
MIN/MAX Recording Accuracy | |||
DC functions | ±12 counts for changes > 350 mS in duration. | ||
AC functions | ±40 counts for changes > 900 mS in duration. | ||
General Specifications | |||
Maximum voltage between any terminal and earth ground | 1000 VDC or AC rms | ||
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | ||
Display (LCD) | Update rate | 4/sec | |
Volts, amps, ohms | 6000 counts | ||
Frequency | 10,000 counts | ||
Capacitance | 1,000 counts | ||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | ||
Battery life | 250 hours minimum | ||
RF communications | 2.4 GHZ ISM Band | ||
RF communication range | Open air, unobstructed | Up to 20m | |
Obstructed, sheetrock wall | Up to 6.5m | ||
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5m | ||
Temperature | Operating | -10°C to 50°C | |
Storage | -40°C to 60°C | ||
Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | ||
Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) | ||
Altitude | Operating | 2,000 m | |
Storage | 12,000 m | ||
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE | ||
Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 | ||
Certifications | CSA, FCC, CE | ||
Ingress Protection (IP) rating | IP54 | ||
Pollution Degree | 2 | ||
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||
Weight | 340 g (12 oz) | ||
Warranty | Three years | ||
Not compatible with Fluke CNX test tools |
Fluke a3001 FC Wireless iFlex AC Current Module
Specifications | ||
Range | 0.5 A to 2500 A AC | |
Resolution | 0.1 A | |
Accuracy | 3% ± 5 digits (5 Hz to 500 Hz) | |
Crest factor (50 Hz / 60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 | |
LCD w/backlight | 3½ digits | |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel | |
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |
Battery life | 400 hours | |
Memory | Record up to 65,000 readings | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20 m |
Obstructed, sheetrock wall | Up to 6.5 m | |
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Temperature coefficient | Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C | |
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
EMC | EN 61326-1:2006 | |
Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition | |
Safety rating | CAT IV 600 V, CAT III 1000 V | |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |
Ingress Protection (IP) rating | IP42 | |
Pollution Degree | 2 | |
Jaw opening | 25.4 cm (10 in) coil | |
Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |
Weight | .22 kg (8 oz) | |
Warranty | Three years | |
Not compatible with Fluke CNX test tools |