Fluke Ti105 a3001 FC iFlex Kit - DISCONTINUED

SKU
FLK-TI105 30HZ/FCA KIT
Manufacturer:
Fluke
Fluke

Key Features:

This Product is DISCONTINUED
Please see the Fluke TiS45 as a Recommended Replacement

The Ti105 offers:

  • Fluke Connect ™ compatible – the largest network for wirelessly enabled tools. Take advantage of the benefits of Fluke Connect™ by sharing inspection results instantly, with any team member, at any time.
  • Rugged, lightweight, point-and-shoot focus free thermal camera
  • One-handed, easy-to-use user interface
  • Included SmartView® and SmartView Mobile App Analysis and Reporting Software

The 3000 FC Wireless Multimeter offers:

  • AC and DC voltage measurements to 1000 V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier. The a3001 FC offers:

  • One (1) true-RMS flexible current meter
  • One (1) iFlex i2500-10 flexible current probe
  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
  • Magnetic hanging strap
Call For Price

Secured and trusted checkout with

Identify issues before they become expensive failures with Fluke’s Ti105 a3001 FC iFlex Kit. The kit is comprised of the Fluke Ti105 Infrared Camera, the Fluke 3000 FC Wireless Multimeter and the Fluke a3001 FC iFlex AC Wireless Current Module. Now, users can connect the a3001 to the desired test point and see the results up to distances of 20 meters away on the Fluke 3000 FC DMMM. The a3001 assists in measurements around confined or award spaces and sizes making wire access effortless, while the Ti105 is equipped with IR Fusion Technology for precision documentation. Even more, all measurement data can be uploaded to the Cloud by a smart phone for later analysis and collaboration.

 

Fluke Connect® with ShareLive™ video call is the most comprehensive software and wireless test tool family that keeps you in contact with your entire team without leaving the field. The Fluke Connect family offers the largest system of connected test tools in the world. The software is compatible with the HTC One and One M8 running Android 4.4.x or higher, LG G3 and Nexus 5 running Android 4.4.x or higher, Samsung Galaxy S4 running Android 4.3.x or higher, Samsung Galaxy S5 running Android 4.4.x or higher. It also works with the iPhone models 4S and higher running iOS 8.0 or higher, iPad Air and iPad Mini (2nd generation) in an iPhone frame on iPad and iPod Touch (5th generation) and comes with over 30 different Fluke products.  Please see our Fluke Connect category for the complete collection of Fluke Connect Products.  Take me to Fluke Connect (Click Here).

 

Save time and increase productivity in the field with Fluke Connect    

 

  • • Share images in real-time across teams with Fluke Connect
  • Save time by creating and emailing reports from the jobsite
  • Capture multiple measurements all in one report
  • WiFi upload and free storage with Fluke Cloud™
  • Store thousands of images with internal 4 GB memory and external slot

Fluke Ti105 Infrared Camera

Detailed Specifications
IR resolution (FPA size)160 x 120 FPA Uncooled Microbolometer
Spectral band7.5 µm to 14 µm (long wave)
Capture or refresh rate30 Hz version
NETD (thermal sensitivity)≤ 0.10°C at 30°C target temp (100 mK)
FOV (field of view)22.5° H x 31° V
IFOV (spatial resolution)3.39 mRad
Temperature measurement range (not calibrated below -10°C)-20°C to + 250°C (-4°F to 482°F)
Temperature measurement accuracy±2°C or 2% (at 25°C nominal, whichever is greater)
Focus mechanismFocus-free 1.2 m (4 ft) and beyond
IR Fusion® technologyPIP (1.2 m (4 ft) to 4.6 m (15 ft)), full IR, full visible
Fluke Connect compatibilityYes (where available)
Color alarms-
Standard palettesBlue-red, ironbow, grayscale and amber
Ultra Contrast™ palettes-
Hot/cold markers-
User definable spot markersIn SmartView® only
CenterpointYes
Centerbox (MIN/AVG/MAX)-
Level and span controlManual and auto
Minimum span in auto mode5°C
Minimum span in manual mode2.5°C
Minimum IR focus distance122 cm (48 in)
Weight0.726 kg (1.6 lb)
Size28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display3.5 inch diagonal (portrait format)
Visible camera2 megapixel industrial-grade
Minimum parallax~122 cm (48 in)
IR-PhotoNotes™ annotation system-
Laser pointerYes
TorchYes
Electronic (cardinal) compass-
Emissivity correctionYes
Transmission correction-
Background (reflected) compensationYes
Voice annotation (audio)-
Multi-mode video output-
Multi-mode video recording (standard AVI with MPEG encoding)-
Multi-mode video recording (radiometric .IS3)-
Memory reviewThumbnail review
Battery (field-replaceable, rechargeable)One
Battery life4+ hours (each)*
External battery charging baseOptional (accessory)
Charging power supplyYes
Drop test2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529)IP 54
Recommended calibration cycleTwo-years
Multifunction card reader-
Memory storage2 GB SD memory card
Direct download capabilityMini USB download direct to PC
Operating temperature range-10°C to +50°C (14°F to 122°F)
Storage temperature range-20°C to +50°C (-4°F to 122°F)
Operating humidityOperating and storage 10% to 95%, non-condensing
Vibration and shock2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standardsIEC 61010-1: Cat None, Pollution Degree 2
C TickIEC/EN 61326-1
EMI, RFI, EMCEN61326-1; FCC Part 5
User manualsCzech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty periodTwo-years
Extended warranty and service plansYes
*Assumes 50% brightness of LCD

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ± ([% of Reading ] + [ Number of least significant digits ]).

Fluke 3000 FC Series Wireless Multimeter

AC Voltage
Range (1) / resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy (2) (3) (4)45 Hz to 500 Hz1.0% + 3
500 Hz to 1 kHz2.0% + 3
(1) All AC voltage ranges are specified from 1% of range to 100% of range.
(2) Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
(3) For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
(4) Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mVRange / resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
ΩRange / resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF (1) / 1 μF
Accuracy1.2% + 2
10% typical
(1) In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
mA AC
(45 Hz to 1 kHz)
Range (1) / resolution60.00 mA / 0.01 mA
400.0 mA (3)/ 0.1 mA
Accuracy1.5% + 3
mA DC (2)Range (1) / resolution60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mA
Accuracy0.5% + 3
(1) All AC current ranges are specified from 5% of range to 100% of range.
(2) Input burden voltage (typical): 400 mA input 2 mV/mA.
(3) 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy (1)0.1% + 1
(1) Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Overload protection1100 Vrms
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 Vrms
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 Vrms
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Overload protection1100 Vrms
Input impedance (nominal)< 2.7 VDC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
< 0.7 VDC
< 0.9 VDC
Typical short circuit current< 350 mA
Overload protection1100 Vrms
Input impedance (nominal)< 2.7 VDC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
2.000 VDC
Typical short circuit current< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions±12 counts for changes > 350 mS in duration.
AC functions±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 VDC or AC rms
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20m
Obstructed, sheetrock wallUp to 6.5m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

Fluke a3001 FC Wireless iFlex AC Current Module

Specifications
Range0.5 A to 2500 A AC
Resolution0.1 A
Accuracy3% ± 5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz / 60 Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficientAdd 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating humidity90% at 35°C
75% at 40°C
45% at 50°C
AltitudeOperating2,000 m
Storage12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Jaw opening25.4 cm (10 in) coil
Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools