logo
www.instrumentation2000.com
C/O Industrial Process Measurement, Inc.
3910 Park Ave, Unit 7
Edison, NJ 08820 USA
(732) 632-6400
GW Instek GPT-9804 5000V AC - 6000V DC Hipot Tester and Safety Analyzer

GW Instek GPT-9804 5000V AC - 6000V DC Hipot Tester and Safety Analyzer

Manufacturer: GW Instek
Price: $2,888.00
Part Number: GPT-9804
CLICK HERE TO VIEW PRODUCT
Product Details

The GPT-9800 Series look to meet a variety of safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety-related requirements for the safety tests of electronic products and components. The GPT-9804 is a 4-in-1 model capable of performing AC withstanding, DC withstanding, insulation resistance and ground bond tests.


 

 

Specifications
AC WITHSTANDING
Output-Voltage Range 0.100kV~ 5.000kV ac
Output-Voltage Resolution 2V/step
Output-Voltage Accuracy ± (1% of setting +5V) [no load]
Maximum Rated Load 200 VA (5kV/40mA)
Maximum Rated Current 40mA (0.5kV < V ≦ 5kV)10mA (0.1kV ≦ V≦ 0.5kV)
Output-Voltage Waveform Sine wave
Output-Voltage Frequency 50 Hz / 60 Hz selectable
Voltage regulation ± (1% of reading +5V) [full load → no load]
Voltmeter Accuracy ± (1% of reading+ 5V)
Current Measurement Range 0.001mA~040.0mA
Current Best Resolution 0.001mA / 0.01mA / 0.1mA
AC Current Measurement Accuracy ±(1.5% of reading +30 counts) when HISET < 1.00mA±(1.5% of reading +3 counts) when HISET ≧ 1.00mA
Window Comparator Method Yes
ARC Detect Yes
RAMP (Ramp-Up Time) 0.1~999.9s
TIMER (Test Time)* OFF, 0.5s~999.9s
GND ON/OFF

DC WITHSTANDING

Output-Voltage Range 0.100kV~ 6.000kV dc
Output-Voltage Resolution 2V/step
Output-Voltage Accuracy ± (1% of setting +5V) [no load]
Maximum Rated Load 50W (5kV/10mA)
Maximum Rated Current 10mA (0.5kV < V ≦ 6kV)2mA (0.1kV ≦ V≦ 0.5kV)
Voltage regulation ± (1% of reading +5V) [full load → no load]
Voltmeter Accuracy ± (1% of reading+ 5V)
Current Measurement Range 0.001mA~010.0mA
Current Best Resolution 0.001mA / 0.01mA / 0.1mA
DC Current Measurement Accuracy ±(1.5% of reading +30 counts) when HISET < 1.00mA±(1.5% of reading +3 counts) when HISET ≧ 1.00mA
Window Comparator Method Yes
ARC Detect Yes
RAMP (Ramp-Up Time) 0.1~999.9s
TIMER (Test Time)* OFF, 0.5s~999.9s
GND ON/OFF

INSULATION RESISITANCE

Output-Voltage 50V~1000V dc
Output-Voltage Resolution 50V/step
Output-Voltage Accuracy ± (1% of setting +5V) [no load]
Resistance Measurement Range 1MW~ 9500MW
  Test voltage Measurable Range Accuracy
  50V≦V≦450V 1MW~ 50MW51MW~ 2000MW ±(5% of reading +1 count)±(10% of reading +1 counts)
  500V≦V≦1000V 1MW~ 500MW501MW~ 9500MW ±(5% of reading +1 count)±(10% of reading +1 count)
Window Comparator Method Yes
Output Impedance 600kW
RAMP (Ramp-Up Time) 0.1~999.9s
TIMER (Test Time) 1s~999.9s
GND OFF (fixed)

GROUND BOND

Output-Current Range 03.00A~30.00A ac
Output-Current Resolution 0.01A
Output-Current Accuracy 3A≦I≦8A : ± (1% of setting +0.2A)8A<I≦30A : ± (1% of setting +0.05A)
Test-Voltage 6Vac max. (open circuit)
Test-Voltage Frequency 50 Hz / 60 Hz selectable
Resistance Measurement Range 10mW~650.0mW
Resistance Measurement Resolution 0.1mW
Resistance Measurement Accuracy ± (1% of reading +2mW)
Window Comparator Method Yes
TIMER (Test Time) 0.5s~999.9s
GND OFF (fixed)
Test Method Four Terminal

MEMORY

Single Step Memory MANU : 100 blocks
Automatic Testing Memory AUTO : 100 blocks, menu per auto : 16

INTERFACE

RS232 Standard
USB (Device) Standard
GPIB Option
Remote Terminal (Front) Standard
SIGNAL IO Standard

General

DISPLY 240 x 64 dot matrix LED back light LCD
POWER SOURCE AC100V/120V/220V/230V ±10%, 50/60Hz
POWER CONSUMPTION 500VA max.
DIMENSIONS & WEIGHT 330(W) x 148(H) x 452(D) mm (Max.),approx.19kg(Max)

* The “TIMER OFF” can only be performed when the tester is in the special MANU mode

We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.