The Fluke 279 FC/iFlex includes 279 FC TRMS Thermal Multimeter, an 18” (45.72 cm) iFlex Flexible Current Probe, TL175 test leads, rechargeable lithium ion battery and charger, soft carrying case and TPAK hanging strap. The 279 FC is designed with all the benefits of a basic thermal imager and tosses in a TRMS multimeter. The 279 FC/iFlex the ability to detect heating of insulators, fuses, splices, wires, connectors and switches plus the added iFlex current measurement adpater, adding measurement of AC current to 2500 Amps. The 279FC also allows you to hunt for hot spots on high-voltage insulators and transformers from a safe working distance.
The Fluke 279 FC is part of the Fluke Connect family of wireless tools! Fluke Connect® with ShareLive™ video call is the most comprehensive software and wireless test tools family that keeps you in contact with your entire team without leaving the field. The Fluke Connect software is compatible with most smart phones and tablets. The Fluke Connect family is the largest system of connected test tools in the world. Please see our Fluke Connect category for the complete collection of Fluke Connect Products. Take me to Fluke Connect (Click Here).
Set up and sustain preventive maintenance procedures easily using the Fluke Connect® system of wireless test tools and asset management software.
• Improve your ability to prevent or predict machine failures
• Make confident decisions with data you can trust and track
• Access your infrared images from anywhere, anytime with secure cloud storage
• Connect and collaborate with your team – even when you are in different places
• Provide more complete information to your maintenance teams
• Generate work orders that include measurements and infrared images
• Edit and analyze images; create and send reports from your smartphone directly from the field
Specifications
Fluke 279 FC Specifications
AC Voltage
Range1/resolution
600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy2, 3, 4, 5
45 Hz to 65 Hz
1.0 % + 3
65 Hz to 200 Hz
4.0 % + 3
200 Hz to 500 Hz
15 % + 3
AC mV
Range1/resolution
600.0 mV / 0.1 mV
Accuracy2, 3, 4
45 Hz to 500 Hz
1.0 % + 3
1 AC voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidal waveforms, add - (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4 Do not exceed 107 V-Hz.
5 Full-time low pass filter
DC Voltage
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy
6 V, 60 V, 600 V
0.09 % + 2
1000 V
0.15 % + 2
DC mV
Range/resolution
600.0 mV / 0.1 mV
Accuracy
0.09 % + 2
Continuity
Range/resolution
600 Ω / 1 Ω
Accuracy
Meter beeps at < 25 Ω, beeper detects opens or shorts of 600 μs or longer
Resistance
Range/resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy
600 Ω
0.5 % + 2
6 kΩ to 600 kΩ
0.5 % + 1
50 MΩ
1.5 % + 3
Diode Test
Range/resolution
2.000 V / 0.001 V
Accuracy
1 % + 2
Capacitance
Range/resolution
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy
1000 nF thu 100 µF
1.2 % + 2
9999 µF
10 % typical
1In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC Current
Range/resolution
999.9 A / 0.1 A
2500 A / 1 A (with iFlex)
Accuracy
45 Hz to 500 Hz
3.0 % + 5
Frequency
Range/resolution
99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
Accuracy
0.1 % + 1
Input Characteristics
AC voltage
Input impedance (nominal)
> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
Overload protection
1100 V rms
DC voltage
Input impedance (nominal)
> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection
> 60 dB at 50 Hz or 60 Hz
Overload protection
1100 V rms
AC mV / DC mV
Input impedance (nominal)
> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection
> 60 dB at 50 Hz or 60 Hz
Overload protection
1100 V rms
Resistance / capacitance
Open circuit test voltage
< 2.7 V DC
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ
< 0.7 V DC
< 0.9 V DC
Typical short circuit current
< 350 mA
Overload protection
1100 V rms
Continuity / diode test
Open circuit test voltage
< 2.7 V DC
Full scale voltage
2.000 V DC
Typical short circuit current
< 1.1 mA
MIN/MAXrecordingaccuracy
AC functions
40 counts for changes > 900 ms in duration
DC functions
12 counts for changes > 350 ms in duration
Infrared Camera
Infrared camera temperature
Range
-10 ˚C to 200 °C (14 °F to 392 °F)
Measurement resolution
0.1 °C
Temperature measurement
Yes, centerpoint
Accuracy
±5 ˚C or ± 5 % (as tested at 25 ˚C, whichever is greater)
Emissivity
0.95 fixed
Image performance
Resolution
80 x 60
Image capture frequency
8 Hz
Detector type
Uncooled vanadium oxide
Thermal sensitivity (NETD)
≤ 200 mK
Infrared spectral band
7.5 µm to 14 µm
Distance to spot
162:1
Field of view
36 ˚(w) x 27 ˚(h)
Focus mechanism
Fixed focus
Image presentation
Palette
Ironbow
Level and span
Auto
Image capture and data storage
Image capture
Image available for review before a save
Storage medium
Internal memory stores up to 100 images
Image transfer
Fluke Connect® / SmartView®
File format
is2
Display size
8.9 cm (3.5 in) diagonal
General Specifications
Maximum voltage between anyterminal and earth ground
1000 V
Display (LCD)
Update rate
4/sec
Volts, amps, ohms
6000 counts
Frequency
10000 counts
Capacitance
1000 counts
Battery type
Fluke BP500 lithium ion battery
Battery life
10 hours minimum
RF communications
2.4 GHZ ISM Band
RF communication range
Open air, unobstructed
Up to 20 m
Obstructed, sheetrock wall
Up to 6.5 m
Obstructed, concrete wall, or steelelectrical enclosure
Up to 3.5 m
Temperature
Operating
-10 °C to 50 °C (14 °F to 122 °F)
Storage
-20 °C to 60 °C (-4 °F to 140 °F)
Temperature coefficient
0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C)
Relative humidity
0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C)
Altitude
Operating
2000 m
Storage
12000 m
Certifications
CSA, FCC, CE
Size (H x W x L)
5.7 cm x 9.4 cm x 21.6 cm (2.3 in x 3.7 in x 8.5 in)
Weight
0.80 kg (1.75 lb)
Warranty
Three years
Includes
• 279 FC TRMS Thermal Multimeter
• 18-inch iFlex Flexible Current Probe
• TL175 Test Leads
• Rechargeable Lithium Ion Battery and Charge
• Soft Carrying Case
The store will not work correctly when cookies are disabled.