The Rotronic HygroFlex5 measuring range is within 0 to 100 %RH and -100 to 200°C (-148 to 392°F), depending on the probe.
The HF5 is designed for fixed installation in HVAC and industrial applications. The HF5 transmitter is compatible with HygroClip2 probes with incorporated AirChip3000 technology. The HC2 (HygroClip2) probe achieves an unparalleled degree of accuracy that has never been seen before. With the combination of advances in sensor technology and integration, the HygroFlex HF52, HF53, HF54, HF55 and HF56 transmitters combined with a HC2-S probe provide superb precision and state-of-the-art functionality.
Easy to read display • Display of the measured values on a clear,backlit graphic display with trend indicators • Configuration by keypad possible
Tried-and-tested housing • Robust industrial housing • Wall or duct mount versions
Power supply • 15 to 40 VDC/12 to 28 VAC • 9 to 36 VDC/7 to 24 VAC (galvanically separated) • 85 to 240 VAC (galvanically separated) • Power over Ethernet (PoE)
Output signals • Two freely selectable and scalable analogue outputs • Available as 2-wire (HF52), 3/4-wire (HF53), 3/4-wire (HF54, HF56 with galvanic isolation)and digital (HF55) transmitter • Optional digital outputs allow integration on a networkvia or RS-485, Ethernet - wired or wireless • Combined digital and analogue output signals,allow control and monitoring of a device with one transmitter
Wide selection of probes • Compatible with all HygroClip2 probes • Use of probe simulators allows easy system validation
AirChip3000 • Compensates humidity and temperature over 30,000 reference points • Dew/frost point calculation • Active alarming and information • ASIC (Application Specific Integrated Circuit), micro-controller and EEPROM on one chip
Specifications
HF52 2-wire
HF53/54/56 3/4-wire
HF55 Digital
Probe type
HygroClip2 probe, all models (1)
Probe cable extension
Passive: max. 5 m, active 100 m
Accuracy at 23 ±5 °C
probe dependent
Response time t 63
probe dependent
Start-up
HF53/54/55/56: typically 3s, HF52: 10s
Measurement range
probe dependent
Electronics operating range
HF53/54/55/56: -40…60 °C / 0…100 %rh HF52: -25...60 °C (-10…60 °C with LCD)
Display (option) (HF52: no backlight)
Graphic display, backlit Parameters configurable
Trend indicators
Yes
Output signals (analogue)
Scalable by user 0...1 V, 0...5 V, 0...10 V, 0(4)...20 mA
HF52: 2 x 2 wires, HF53/54/56: 3/4 wires HF55: digital
Min. / Max. load
V-signal: ≥1 kΩ/V / mA-signal: ≤500 Ω
Load compensation
Yes
Firmware update
Via service connector, requires HW4 software
Sensor diagnostics (drift, state)
Programmable. Default: off
Humidity adjustment
With keypad/software: multi point (HF53/54/55/56)
Temperature adjustment
With keypad: 1 point Software: 2 points (HF53/54/55/56)
Data logging function
External, 2000 data point memory
Psychrometric calculations
All selectable
PC interface
With ROTRONIC interface cable HW4 compatible
Data processing by HW4
Graphs, statistical data and analysis, qualification etc.
Housing material
ABS / Aluminium (HF5xxS)
Cable connections
1 x M16x1.5, on terminals
Standards
CE- compliant, 2007/108/EG
Audit trail, Electronic Records
FDA 21 CFR Part 11 and GAMP compliant
IP protection rating & fire
IP65 / Corresponds to UL94-HB protection class
(1): HF520 transmitter is not compatible with industrial metal probes
Dimensions
Ordering Codes
Notes:
• The HF53 can be ordered with both analog and digital interface (see "cable fittings" in the table).
• The enclosure of all models with optional display and keypad and/or with digital interface is designed to beinstalled in the horizontal position.
• The M16 cable grip is located at the bottom of the enclosure. The 1/2" conduit adapter in located on top of the enclosure.
• The factory default setting for the dew point calculation is frost point below freezing.
• The calculated parameter uses the same unit system (metric or English) as the temperature output.
• Custom range: be sure to clearly specify the desired range at the time of order. When a special range has been ordered,the letters ST, SC or S are used in column 4, 7 or 8 in the above table. These generic codes will be replaced with a specificcode only for quantity and repeat orders.
• The probe used with the HF5 must be ordered separately. For technical information on the different probe models, refer todocument E-M-HC2 Probes-V1.
• One (1) AC5005 mounting flange is included with the HF52 and HF53 duct mount transmitter.