Rotronic HygroFlex5 Humidity & Temperature Transmitter

SKU
HF5
Manufacturer:
Rotronic
Rotronic

Key Features:

  • Relative humidity and temperature measurement
  • Dew Point and other psychrometric calculations
  • Interchangeable probe for easy maintenance
  • Wide choice of probes to satisfy every application
  • Low voltage and mains versions
  • Freely scalable analogue signals
  • Various digital outputs available
Product Options:

Maximum 25 characters

$467.00

Secured and trusted checkout with

The Rotronic HygroFlex5 measuring range is within 0 to 100 %RH and -100 to 200°C (-148 to 392°F), depending on the probe.

The HF5 is designed for fixed installation in HVAC and industrial applications. The HF5 transmitter is compatible with HygroClip2 probes with incorporated AirChip3000 technology. The HC2 (HygroClip2) probe achieves an unparalleled degree of accuracy that has never been seen before. With the combination of advances in sensor technology and integration, the HygroFlex HF52, HF53, HF54, HF55 and HF56 transmitters combined with a HC2-S probe provide superb precision and state-of-the-art functionality.

Easy to read display
• Display of the measured values on a clear, backlit graphic display with trend indicators
• Configuration by keypad possible

Tried-and-tested housing
• Robust industrial housing
• Wall or duct mount versions

Power supply
• 15 to 40 VDC/12 to 28 VAC
• 9 to 36 VDC/7 to 24 VAC (galvanically separated)
• 85 to 240 VAC (galvanically separated)
• Power over Ethernet (PoE)

Output signals
• Two freely selectable and scalable analogue outputs
• Available as 2-wire (HF52), 3/4-wire (HF53), 3/4-wire (HF54, HF56 with galvanic isolation) and digital (HF55) transmitter
• Optional digital outputs allow integration on a network via or RS-485, Ethernet - wired or wireless
• Combined digital and analogue output signals, allow control and monitoring of a device with one transmitter

Wide selection of probes
• Compatible with all HygroClip2 probes
• Use of probe simulators allows easy system validation

AirChip3000
• Compensates humidity and temperature over 30,000 reference points
• Dew/frost point calculation
• Active alarming and information
• ASIC (Application Specific Integrated Circuit), micro-controller and EEPROM on one chip

 

   HF52  
  2-wire
    HF53/54/56
    3/4-wire
   HF55
   Digital
Probe typeHygroClip2 probe, all models (1)
Probe cable extensionPassive: max. 5 m, active 100 m
Accuracy at 23 ±5 °Cprobe dependent
Response time t 63probe dependent
Start-upHF53/54/55/56: typically 3s, HF52: 10s
Measurement rangeprobe dependent
Electronics operating range


HF53/54/55/56: -40…60 °C / 0…100 %rh
HF52: -25...60 °C
(-10…60 °C with LCD)
Display (option)
(HF52: no backlight)
Graphic display, backlit
Parameters configurable
Trend indicatorsYes
Output signals (analogue)

Scalable by user
0...1 V, 0...5 V, 0...10 V, 0(4)...20 mA
Digital outputs (optional)Ethernet (LAN, WLAN), USB, RS-485
Power supply



HF52: 10...28 VDC: 10 V+(0.02x load)
HF53/55: 15…40 VDC /12…28 VAC
HF54 with galvanic isolation: 9...36 VDC
HF56 with galvanic isolation: 85...240 VAC
Power consumptionHF52: max 40 mA
 HF53 <100mA, HF55 <300mA
Circuit type

HF52: 2 x 2 wires, HF53/54/56: 3/4 wires
HF55: digital
Min. / Max. loadV-signal: ≥1 kΩ/V / mA-signal: ≤500 Ω
Load compensationYes
Firmware updateVia service connector, requires HW4 software
Sensor diagnostics (drift, state)Programmable. Default: off
Humidity adjustmentWith keypad/software: multi point (HF53/54/55/56)
Temperature adjustment

With keypad: 1 point
Software: 2 points (HF53/54/55/56)
Data logging functionExternal, 2000 data point memory
Psychrometric calculationsAll selectable
PC interfaceWith ROTRONIC interface cable HW4 compatible
Data processing by HW4Graphs, statistical data and analysis, qualification etc.
Housing materialABS / Aluminium (HF5xxS)
Cable connections1 x M16x1.5, on terminals
StandardsCE- compliant, 2007/108/EG
Audit trail, Electronic RecordsFDA 21 CFR Part 11 and GAMP compliant
IP protection rating & fireIP65 / Corresponds to UL94-HB protection class

(1): HF520 transmitter is not compatible with industrial metal probes

Dimensions


 

Ordering Codes




Notes:

  • • The HF53 can be ordered with both analog and digital interface (see "cable fittings" in the table).
  • The enclosure of all models with optional display and keypad and/or with digital interface is designed to be installed in the horizontal position.
  • The M16 cable grip is located at the bottom of the enclosure. The 1/2" conduit adapter in located on top of the enclosure.
  • The factory default setting for the dew point calculation is frost point below freezing.
  • The calculated parameter uses the same unit system (metric or English) as the temperature output.
  • Custom range: be sure to clearly specify the desired range at the time of order. When a special range has been ordered, the letters ST, SC or S are used in column 4, 7 or 8 in the above table. These generic codes will be replaced with a specific code only for quantity and repeat orders.
  • The probe used with the HF5 must be ordered separately. For technical information on the different probe models, refer to document E-M-HC2 Probes-V1.
  • One (1) AC5005 mounting flange is included with the HF52 and HF53 duct mount transmitter.



Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account






Products In This Series

As low as

Now $520.00

As low as

Now $630.00