We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Rotronic HygroFlex5 measuring range is within 0 to 100 %RH and -100 to 200°C (-148 to 392°F), depending on the probe.
The HF5 is designed for fixed installation in HVAC and industrial applications. The HF5 transmitter is compatible with HygroClip2 probes with incorporated AirChip3000 technology. The HC2 (HygroClip2) probe achieves an unparalleled degree of accuracy that has never been seen before. With the combination of advances in sensor technology and integration, the HygroFlex HF52, HF53, HF54, HF55 and HF56 transmitters combined with a HC2-S probe provide superb precision and state-of-the-art functionality.
Easy to read display |
HF52 2-wire | HF53/54/56 3/4-wire | HF55 Digital | |
Probe type | HygroClip2 probe, all models (1) | ||
Probe cable extension | Passive: max. 5 m, active 100 m | ||
Accuracy at 23 ±5 °C | probe dependent | ||
Response time t 63 | probe dependent | ||
Start-up | HF53/54/55/56: typically 3s, HF52: 10s | ||
Measurement range | probe dependent | ||
Electronics operating range | HF53/54/55/56: -40…60 °C / 0…100 %rh HF52: -25...60 °C (-10…60 °C with LCD) | ||
Display (option) (HF52: no backlight) | Graphic display, backlit Parameters configurable | ||
Trend indicators | Yes | ||
Output signals (analogue) | Scalable by user 0...1 V, 0...5 V, 0...10 V, 0(4)...20 mA | ||
Digital outputs (optional) | Ethernet (LAN, WLAN), USB, RS-485 | ||
Power supply | HF52: 10...28 VDC: 10 V+(0.02x load) HF53/55: 15…40 VDC /12…28 VAC HF54 with galvanic isolation: 9...36 VDC HF56 with galvanic isolation: 85...240 VAC | ||
Power consumption | HF52: max 40 mA | ||
HF53 <100mA, HF55 <300mA | |||
Circuit type | HF52: 2 x 2 wires, HF53/54/56: 3/4 wires HF55: digital | ||
Min. / Max. load | V-signal: ≥1 kΩ/V / mA-signal: ≤500 Ω | ||
Load compensation | Yes | ||
Firmware update | Via service connector, requires HW4 software | ||
Sensor diagnostics (drift, state) | Programmable. Default: off | ||
Humidity adjustment | With keypad/software: multi point (HF53/54/55/56) | ||
Temperature adjustment | With keypad: 1 point Software: 2 points (HF53/54/55/56) | ||
Data logging function | External, 2000 data point memory | ||
Psychrometric calculations | All selectable | ||
PC interface | With ROTRONIC interface cable HW4 compatible | ||
Data processing by HW4 | Graphs, statistical data and analysis, qualification etc. | ||
Housing material | ABS / Aluminium (HF5xxS) | ||
Cable connections | 1 x M16x1.5, on terminals | ||
Standards | CE- compliant, 2007/108/EG | ||
Audit trail, Electronic Records | FDA 21 CFR Part 11 and GAMP compliant | ||
IP protection rating & fire | IP65 / Corresponds to UL94-HB protection class |
(1): HF520 transmitter is not compatible with industrial metal probes
Dimensions
Ordering Codes
Notes:
- • The HF53 can be ordered with both analog and digital interface (see "cable fittings" in the table).
- • The enclosure of all models with optional display and keypad and/or with digital interface is designed to be installed in the horizontal position.
- • The M16 cable grip is located at the bottom of the enclosure. The 1/2" conduit adapter in located on top of the enclosure.
- • The factory default setting for the dew point calculation is frost point below freezing.
- • The calculated parameter uses the same unit system (metric or English) as the temperature output.
- • Custom range: be sure to clearly specify the desired range at the time of order. When a special range has been ordered, the letters ST, SC or S are used in column 4, 7 or 8 in the above table. These generic codes will be replaced with a specific code only for quantity and repeat orders.
- • The probe used with the HF5 must be ordered separately. For technical information on the different probe models, refer to document E-M-HC2 Probes-V1.
- • One (1) AC5005 mounting flange is included with the HF52 and HF53 duct mount transmitter.