Vaisala DMT152 DRYCAP Dewpoint Transmitter

SKU
DMT152
Manufacturer:
Vaisala
Vaisala

Key Features:

  • Compact
  • Accurate
  • Vaisala DRYCAP® technology with a polymer sensor
  • Measures dewpoint down to -80 C (-112 F)
  • Reduced maintenance costs due to long calibration interval
  • Withstands condensation
  • Compatible with the Vaisala MI70 indicator
  • NIST Traceable
  • Fast response time
Product Options:
$2,282.00

Secured and trusted checkout with

The Vaisala DRYCAP® Dewpoint Transmitter DMT152 is a small-size dewpoint measurement instrument designed for measuring dry air or gas in OEM applications.

The Vaisala DMT152 can measure dewpoint even down to -80 C (-112 F) or 1 ppm of humidity.

 

The accuracy and reliability of the DMT152 performance is based on the Vaisala DRYCAP® polymer sensor technology. It has a low maintenance need due to the long-term stability and durability against condensation. The DMT152 mechanics have been designed for harsh environments requiring protection against dust, dirt, and splashed water.

 

Typical areas of application are air and plastics dryers, dry chambers, pure gases, and high-voltage circuit breakers. The DMT152 measures accurately and reliably also in the combination of low humidity and hot air, typical in plastics drying.

Measured Variables
DEW POINT TEMPERATURE 
Measurement range-80 ... -10 °C (-112 ... +14 °F)Td
Accuracy 
-80 ... -30 °C (-112 ... -22 °F)
-30 ... -10 °C (-22 ... +14 °F)
±2 °C (3.6 °F) Td
±3 °C (5.4 °F) Td
Non-calibrated range-100 ... -80 °C, -10 ... +20 °C Td
(-148 ... -112 °F, +14 ... +68 °F Td)
Analog output scalings 
option 1
option 2
option 3
-80 ... +20 °C (-112 ... +68 °F) Td
-100 ... 0 °C (-148 ... +32 °F) Td
user-specified output scaling
when dew point is below 0 °C (32 °F) the transmitter outputs
frost point
Accuracy over temperature range 
Response time 63 % [90 %] at a gas temperature of +20 °C (+68 °F)
and pressure of 1 bar
-10 ... -80 °CTd
-80 ... -10 °CTd
0.5 min [7.5 min]
2 s [5 s]
Typical long-term stabilitybetter than 2 °C (3.6 °F) /year
PPM VOLUME CONCENTRATION 
Measurement range (typical)0 ... 500 ppm
Accuracy at +20 °C (+68 °F),
1013 mbar

±(0.2 ppm + 20 % of reading)
Operating Environment
Temperature40 ... +70 °C (-40 ... +158 °F)
Relative humidity0 ... 100 %RH (up to + 20 °C/68 °F)
Pressure0 ... 50 bar (725 psia)
Measured gasesnon-corrosive gases
Sample flow rateno effect on measurement accuracy
Outputs
Two analog outputs (scalable)4 ... 20 mA, 0 ... 20 mA (3 wire)
0 ... 5 V, 0 ... 10 V
Accuracy of analog outputs± 0.01 V / ±0.01 mA
Digital outputRS485 (2-wire)
Alarm-level indication by analog signaluser selectable
Purge information5 V, 10 V, 20 mA or LED
General
SensorVaisala DRYCAP® 180U
Thin-film capacitive polymer sensor
Recommended calibration interval2 years
Operating voltage with 
RS485 output
voltage output
current output
11* ... 28 VDC
15* ... 28 VDC
21 ... 28 VDC
*For extended temp. down to -40 °C (-40 °F) or pressure up to
50 bar (725 psia), the supply voltage is 21 ... 28 VDC.
Supply current 
normal measurement
during self-diagnostics
20 mA + load current
max. 220 mA pulsed
Supply voltage fluctuationmax. 0.3 V
External load for 
voltage output
current output
min. 10 kOhm
max. 500 Ohm
Housing material (wetted parts)AISI316L
Stainless steel mesh filterFilter body AISI303, mesh
AISI316L, grade 18 μm
Mechanical connectionsISO G½”, NPT ½", UNF 3/4”- 16”
Housing classificationIP65 (NEMA 4)
Storage temperature range-40 ... +80 °C (-40 ... +176 °F)
Weight (ISO G½”)190 g (6.70 oz)
Complies with EMC standard EN61326-1, Electrical equipment for
measurement control and laboratory use - EMC requirements;
Industrial environment

 