Vaisala DMT132 Dewpoint Transmitter for Refrigerant Dryers

SKU
DMT132
Manufacturer:
Vaisala
Vaisala

Key Features:

  • Affordable dew point transmitter for refrigerant dryers
  • High accuracy ±1°C (±1.8°F) in the measurement range of refrigerant dryers
  • Excellent long-term stability - resistant to compressor oil and most other chemicals thanks to HUMICAP technology
  • Low power requirements, 10 .... 28 VDC
  • Easy to verify functionality with compatible hand-held meters DM70 or HM70
  • Optional LED warning light
  • Optional loop powered display, Nokeval 301
Product Options:

Maximum 25 characters

Maximum 25 characters

Maximum 10 characters

Maximum 10 characters

$618.00

Secured and trusted checkout with

Confirm the functionality of refrigerant dryers with Vaisala’s DMT132 Dewpoint Transmitter.

The DMT132 maintains a Td accuracy of +/-1°C (+/-1.8°F) in the typical operating measurement range of -3°C to 20°C (26.6°F to 68°F) while the Vasiala HUMICAP sensor, resistant to compressor oil and many other chemicals, ensures superior long-term stability.

Performance
DEW POINT 
Measurement range-20 ... +50 °C (-4 ... +122 °F) Td
Accuracy (at +20 °C (+68 °F)±1 °C for -3...20 °C (+26.6 ... +68 °F) Td
±2 °C for -15...-3 °C (+5 ... +26.6 °F) Td
* when dew point is below 0 °C (+32 °F), the transmitter outputs
frostpoint
Response time at 20 °C (+68 °F) gas temperature and 1 bar pressure
-14 -> +3 °C (+7 -> +37 °F) Td17 s (63%)
40 s (90%)
+3 -> -14 °C (+37 -> +7 °F) Td33 s (63%)
85 s (90%)
 
Operating Environment
Operating temperature
Operating pressure
Relative humidity
Sample flow rate
Measured gases
-10 ... + 60 °C (+14 ... +140 °F)
0 ... 20 bar
0 ... 100 %RH
no effect on measurement accuracy
gases non-corrosive gases
 
Outputs
Analog output (scalable)4...20 mA, 2-wire
Resolution for current output0.002 mA
Accuracy of analog outputs at +20 °C±0.05% full scale
Typical temperature dependence±0.005% of full scale/ °C
Connector4-pin M8 (IEC 60947-5-2)
LED indication available for defined
dew point limit/ error state indication
RS485 serial line for service use
 
 
General
SensorVaisala HUMICAP®180R
Recommended calibration interval
(in refrigerant dryer application)
2 years
Mechanical connectionG 1/2" ISO
Operating voltage10 .... 28 VDC
External loadmax 100 ohm for supply voltages <20 VDC
max 500 ohm for supply voltages 20...28 VDC
Weight65 g (2.3 oz)
Housing materialPPS + 40% GF
Housing classificationIP65 (NEMA 4)
Storage temperature range-40 ... + 80 °C (-40 ... +176 °F)
Start-up time3 s
Complies with EMC standard EN61326-1, Electrical equipment for measurement control and laboratory use - EMC requirements; Industrial environment