The Texmate UM-35-ACV is a cost-effective AC voltage meter with two header selectable ranges of 199.9V AC and 600V AC. This meter comes standard with a red 3 1/2 digit LED display or you can choose an optional green or super bright LED display.
Input Configuration: | Differential auto zeroing Volts average AC or true RMS AC Volts to DC converter. Inputs are resistively isolated to 1400V from internal ground of meter by 1.94MΩ, so that phase to phase measurements up to 600V AC can be safely made. |
Full Scale Ranges: | Two header selectable ranges of 199.9V AC and 600V AC full scale |
Input Impedance: | 4MΩ minimum |
A/D Converter: | 12 Bit Dual Slope |
Accuracy: | ±(0.05% of reading + 2 counts) |
Temperature Coefficient: | 100ppm/°C (Typical) |
Warm Up Time: | 2 minutes to specified accuracy |
Conversion Rate: | 3 conversions per second (Typical) |
Display: | 3 1/2 digit 0.56" Red LED display (std), Green or Super Bright Red are optional. Range 0 to 1999 counts. |
Decimal Selection: | Header under face plate, X•X•X•X• |
Over-range Indication: | 1 (MSD) displayed with all other digits blank |
Power Supply (std): | 120/240V AC, 50/60/400 Hz. approx 1.5W |
(Optn) VO-DC/ISO | Isolated Switcher. 9 to 36V DC/12 to 24V AC |
Operating Temperature: | –10 to 50 °C |
Storage Temperature: | –20 to 70 °C |
Relative Humidity: | 95% (non-condensing) |
Case Dimensions: | Bezel 3.78”Wx1.89”H (96mm x 48mm) Depth behind bezel 3.36" (83.5mm) Plus 0.5 to .9” (12.7 to 22.8mm) depending on connector used. |
Weight: | NW. 12oz (0.34kg) 15.6oz (0.44kg). when packed. |