Input Configuration:........Single ended
Full Scale Range:............4 to 20mA to read 0 to full scale
Input Impedance:.............Approximately 200Ω
Maximum 4V loop drop at 20mA input
A/D Converter:.................Flash converter
Accuracy:.........................1% of full scale
Temperature Coefficient:...200ppm/ ̊C (typical)
Warm Up Time:.................Instantly reads to specified accuracy
Conversion Rate:.............Instantaneous flash conversion
Display:.............................Thirty-one 0.20” X 0.06” (5.08mm X 1.52mm) bar segments
Over-range Indication:....All bars flash
Power Supply:..................Powered from 4 to 20mA signal
Operating Temperature:..-10 ̊C to 60 ̊C
Storage Temperature:......-20 ̊C to +70 ̊C
Relative Humidity:...........95% (non condensing)
Case Dimensions:...........Bezel: 24X96 mm (0.95” X 3.78”)
Depth behind bezel: 56.5 mm (2.23”)
Plus 27 mm (1.06”) for Push-on connector
or plus 17.5 mm (0.69”) for Edge connector
Weight:..............................90.72 gms (3.2 oz)
136.1 gms (4.8 oz) when packed