Temperature - NTC | |
---|---|
Measuring range | -58° to 302 °F / -50 to +150 °C |
Accuracy | ±0.4 °F (-13° to 166.8 °F) / ±0.2 °C (-25 to +74.9 °C) ±0.7 °F (-58° to -13.2 °F) / ±0.4 °C (-50 to -25.1 °C) ±0.7 °F (167° to 211.8 °F) / ±0.4 °C (+75 to +99.9 °C) ±0.5 % of mv (Remaining Range) |
Resolution | 0.1 °F / 0.1 °C |
Temperature - Type K TC | |
---|---|
Measuring range | -328° to 2498 °F / -200 to +1370 °C |
Accuracy | ±0.5 °F (-76° to 140.0 °F) / ±0.3 °C (-60 to +60 °C) ±(0.4 °F + 0.5 % of mv) (Remaining Range) / ±(0.2 °C + 0.5 % of mv) (Remaining Range) |
Resolution | 0.1 °F / 0.1 °C |
Temperature - TC Type T (Cu-CuNi) | |
---|---|
Measuring range | -328° to 752 °F / -200 to +400 °C |
Accuracy | ±0.5 °F (-76° to 140 °F) / ±0.3 °C (-60 to +60 °C) ±(0.4 °F + 0.5 % of mv) (Remaining Range) / ±(0.2 °C + 0.5 % of mv) (Remaining Range) |
Resolution | 0.1 °F / 0.1 °C |
Humidity - Capacitive | |
---|---|
Measuring range | 0 to +100 %rH |
Accuracy | See probe data |
Absolute Pressure | |
---|---|
Measuring range | 0 to +800 InH₂O / 0 to +2000 hPa |
Accuracy | See probe data |
Resolution | 0.1 InH₂O / 0.1 hPa |
Velocity - Vane anemometer | |
---|---|
Measuring range | 0 to 11811 fpm / 0 to +60 m/s |
Accuracy | See probe data |
Resolution | 0.01 fpm (60 + 100 mm Vane) / 0.01 m/s (60 + 100 mm Vane) 0.1 fpm (16 mm Vane) / 0.1 m/s (16 mm Vane) |
Velocity - Hot wire anemometer | |
---|---|
Measuring range | 0 to +3937 fpm / 0 to +20 m/s |
Accuracy | See probe data |
Resolution | 1.97 fpm / 0.01 m/s |
Light | |
---|---|
Measuring range | 0° to 100000 Lux |
Accuracy | See probe data |
Resolution | 1 Lux 0.1 Hz |
General technical data | |
---|---|
Dimensions | 9 x 3 x 2 in. / 220 x 74 x 46 mm |
Operating temperature | -4° to 122 °F / -20 to +50 °C |
Housing | ABS / TPE / Metal |
Protection class | IP54 |
Battery type | Alkaline, type AA |
Battery life | 200 h (typical vane measurement) |
Display ligthing | Illuminated display |
Storage temperature | -22 to +158 °F / -30 to +70 °C |
Weight | 15 oz. / 428 g |
- Flow measurement in the ventilation duct using a thermal anemometer and vane anemometer
- Measurement at the air outlet
- Measurement of the air and surface temperature
- Measurement of radiated heat
- Lighting measurement
- Turbulence measurement
- U-value measurement
- Measurement of indoor air quality (CO2)
- CO measurement