Socomec DIRIS DigiBOX A40 USDBPA40RS250_KIT Multifunction Meter Kit - DISCONTINUED

SKU
USDBPA40RS250_KIT
Manufacturer:
Socomec
Socomec

Key Features:

This Product is DISCONTINUED
Please see the Socomec USDBPA40ET250_KIT as a Recommended Replacement

  • Easy to install
  • Enlcosure rating NEMA 3R, 4, 4X, 12
  • Compliant with ANSI C12.20
  • Come prewired with fuse holders included
  • cULus 508 A
  • ANSI C12.20
  • IEC 61557-12
Call For Price

Secured and trusted checkout with

The Socomec DIRIS DigiBOX A40 kit (USDBPA40RS250_KIT) includes the DIRIS DigiBOX A40 (USDBPA40RS), 3x TR-21 63-250 amp split core current sensors (48290557) and 3x 6.5’ RJ12 cables.

Electrical characteristics

Auxiliary power supply
Alternative voltage110/400 VAC or 120/300 VDC - Cat III
Frequency50/60 Hz
Power consumption5 VA AC / 1.5 VA DC (48250500)
8 VA AC / 2.5 VA DC (48250501 & 48250502)
ConnectionRemovable spring-cage terminal block, 2 x 2 positions,
AWG 10 … 24 / 2.5 … 0.5 mm² solid cable or
AWG 15 … 30 / 1.5 … 0.25 mm² stranded cable with ferrule

 

Measurement characteristics

Power and energy measurement
Accuracy
Active energy and
active power
Class 0.2 for the DIRIS A-40 only
Class 0.5 with TE, TF or iTR sensors
Class 1 with TR sensors
Accuracy of reactive energyClass 1 with TE, iTR or TF sensors
 
Power factor measurement
AccuracyClass 0.5 with TE, TF or iTR sensors
Class 1 with TR sensors
 
Voltage measurement
Characteristics
of the network
measured
50-300VAC (Ph/N) - 87-520VAC (Ph/Ph) - CAT III
Frequency range45 to 65Hz
Frequency accuracyClass 0.02
Network typeSingle-phase / Two-phase / Two-phase with neutral /
Three-phase / Three-phase with neutral
Measurement by
voltage transformer
Primary: 400 000 VAC
Secondary: 60, 100, 110, 173, 190 VAC
Input consumption≤ 0.1 VA
Accuracy of voltage
measurement
Class 0.2
ConnectionRemovable spring-cage terminal block, 4 positions,
AWG 10 … 24 / 0.5 … 2.5 mm² solid cable or
AWG 15 … 30 / 0.25 … 1.5 mm² stranded cable with ferrule
 
Current measurement
Number of current inputs3
Associated current sensorsSolid TE, split-core TR/iTR, flexible TF current sensors
AccuracyClass 0.2 DIRIS A-40 alone
Class 0.5 with TE, TF or iTR sensors
Class 1 with TR sensors
ConnectionSpecific Socomec cable with RJ12 connectors

 

Input characteristics

Number3
Type / Power supplyOptocoupler with internal (12 VDC ± 10%) or external
(12-24 VDC ± 20%) polarisation
Input functionLogical status, protective device monitoring, pulse metering of multifluid meters.
ConnectionRemovable screw terminal block, 5 positions,
AWG 15 … 35 / 0.14 to 1.5 mm² stranded or solid cable

 

Output characteristics

Number2
TypeOptocoupler 30 Vd.c. max 20mA max - SELV
Output functionCommand, energy pulse output, load shedding, alarm
ConnectionRemovable screw terminal block, 4 positions,
AWG 15 … 35 / 0.14 to 1.5 mm² stranded or solid cable

 

Communication characteristics

Ethernet RJ45 10/100 MbsGateway function
Modbus TCP
BACnet IP
SNMP v1, v2, v3
RS485 2-3 wiresModbus RTU communication function
Profibus DPV1 communication interface
USBUpgrade and configuration via type B micro
USB connector

 

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • • Industry
  • • Infrastructures
  • • Data centres