Socomec DIRIS DigiBOX A40 Enclosed Power Metering & Monitoring w/ Modbus RS485 Output - DISCONTINUED

SKU
USDBPA40RS
Manufacturer:
Socomec
Socomec

Key Features:

This Product is DISCONTINUED
Please see the Socomec USDBPA40ET as a Recommended Replacement

  • Easy to install
  • Enlcosure rating NEMA 3R, 4, 4X, 12
  • Compliant with ANSI C12.20
  • Come prewired with fuse holders included
  • cULus 508 A
  • ANSI C12.20
  • IEC 61557-12
Call For Price

Secured and trusted checkout with

The Socomec DIRIS DigiBOX A40 (USDBPA40RS) is an enclosed single-point measurement unit that is easy to install and ensures the user has access to all the measurements required for successfully carrying out energy efficiency projects and ensuring the electrical distribution is monitored.

Electrical characteristics

Auxiliary power supply
Alternative voltage110/400 VAC or 120/300 VDC - Cat III
Frequency50/60 Hz
Power consumption5 VA AC / 1.5 VA DC (48250500)
8 VA AC / 2.5 VA DC (48250501 & 48250502)
ConnectionRemovable spring-cage terminal block, 2 x 2 positions,
AWG 10 … 24 / 2.5 … 0.5 mm² solid cable or
AWG 15 … 30 / 1.5 … 0.25 mm² stranded cable with ferrule

 

Measurement characteristics

Power and energy measurement
Accuracy
Active energy and
active power
Class 0.2 for the DIRIS A-40 only
Class 0.5 with TE, TF or iTR sensors
Class 1 with TR sensors
Accuracy of reactive energyClass 1 with TE, iTR or TF sensors
 
Power factor measurement
AccuracyClass 0.5 with TE, TF or iTR sensors
Class 1 with TR sensors
 
Voltage measurement
Characteristics
of the network
measured
50-300VAC (Ph/N) - 87-520VAC (Ph/Ph) - CAT III
Frequency range45 to 65Hz
Frequency accuracyClass 0.02
Network typeSingle-phase / Two-phase / Two-phase with neutral /
Three-phase / Three-phase with neutral
Measurement by
voltage transformer
Primary: 400 000 VAC
Secondary: 60, 100, 110, 173, 190 VAC
Input consumption≤ 0.1 VA
Accuracy of voltage
measurement
Class 0.2
ConnectionRemovable spring-cage terminal block, 4 positions,
AWG 10 … 24 / 0.5 … 2.5 mm² solid cable or
AWG 15 … 30 / 0.25 … 1.5 mm² stranded cable with ferrule
 
Current measurement
Number of current inputs3
Associated current sensorsSolid TE, split-core TR/iTR, flexible TF current sensors
AccuracyClass 0.2 DIRIS A-40 alone
Class 0.5 with TE, TF or iTR sensors
Class 1 with TR sensors
ConnectionSpecific Socomec cable with RJ12 connectors

 

Input characteristics

Number3
Type / Power supplyOptocoupler with internal (12 VDC ± 10%) or external
(12-24 VDC ± 20%) polarisation
Input functionLogical status, protective device monitoring, pulse metering of multifluid meters.
ConnectionRemovable screw terminal block, 5 positions,
AWG 15 … 35 / 0.14 to 1.5 mm² stranded or solid cable

 

Output characteristics

Number2
TypeOptocoupler 30 Vd.c. max 20mA max - SELV
Output functionCommand, energy pulse output, load shedding, alarm
ConnectionRemovable screw terminal block, 4 positions,
AWG 15 … 35 / 0.14 to 1.5 mm² stranded or solid cable

 

Communication characteristics

Ethernet RJ45 10/100 MbsGateway function
Modbus TCP
BACnet IP
SNMP v1, v2, v3
RS485 2-3 wiresModbus RTU communication function
Profibus DPV1 communication interface
USBUpgrade and configuration via type B micro
USB connector

 