NK Technologies ATS Series AC Current Transducer/Switch with Digital Setpoint Display

SKU
ATS
Manufacturer:
NK Technologies
NK Technologies

Key Features:

    Solid -State Output
  • N.O. or N.C. solid-state switch for control circuits up to 240VAC
  • Compatible with most automation systems
    Externally powered
  • Allows for higher accuracy
    Easily Adjustable and Precise Setpoint
  • Speeds startup
    Analog Output
  • Measure the current used at all times
    LED Display
  • Provides quick visual indication of where the contact changes
  • Easiest and most accurate setpoint adjustment available
    Built-in Mounting Feet
  • Simple, two-screw panel mount or attach with optional DIN rail brackets
    Designed for UL, CUL and CE Approval
  • Accepted worldwide
Product Options:
$205.00

Secured and trusted checkout with

ATS Series AC Current Sensors combine a current operated switch and transducer into a single package. The FL model features a digital display that gives visual indication of the setpoint for greater accuracy. The sensor provides a solid- state contact which will change state when the current exceeds an adjustable level or falls below the normal running current. This means reduced installation time, plus the option to have local control of a starter coil while at the same time sending the analog signal back to a controller housed in a separate cabinet. Analog Output: ATS1: 050A; ATS2: 0200A

Power Supply18–30 VAC/DC (40–70 mA consumption)
Digital OutputMagnetically isolated solid-state switch
Contact Rating• 1.0 A up to 240 VAC max. (AC only)
Off-State Leakage• <10 μA normally open
• 2.5 mA normally closed
Contact Response
Time
• <500 ms (5% above setpoint)
• <200 ms (50% above setpoint)
• <150 ms (100% above setpoint)
Setpoint Range• ATS1: 1–50 A (adjustable)
• ATS2: 4–200 A (adjustable)
Hysteresis5% of setpoint
Analog Output• ATS1: 0–50 A • ATS2: 0–200 A
Analog Signal
Loading
• 4–20 mA: 500 ohm max.
• 0–5 or 0–10 VDC: 5 K ohm min.
Analog Response
Time
• <300 ms (90% step change)
• <400 ms (100% step change)
OverloadMODEL6 SEC1 SEC
• ATS1
• ATS2
• 400 A
• 800 A
• 600 A
• 1200 A
Isolation VoltageTested to 5000 VAC
Frequency Range40–400 Hz
Sensing Aperture0.74” (19 mm) dia.
CaseUL94 V0 Flammability Rated
Environmental-4 to 122°F (-20 to 50°C)
0–95% RH, non-condensing
ListingsDesigned to meet UL 508 Industrial Control
Equipment (USA & Canada)
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Electronic Proof of Operation

  • Current operated switches eliminate the need for multiple pipe or duct penetrations and are more reliable than electromechanical pressure or flow switches
  • Conveyors

  • Detects jams and overloads
  • Interlocks multiple conveyor sections
  • Pump Control

  • Provides signal to measure current and shuts down the pump if the current rises over the setpoint
  • Cooling Towers

  • Analog monitors time of use and contact opens if a filter clogs