NK Technologies AT/ATR 3 & 4 Series Average Responding or True RMS AC High Current Transducers

SKU
AT/ATR-3/4
Manufacturer:
NK Technologies
NK Technologies

Key Features:

    Large Aperture
  • Accommodates large conductors or wire bundles
    Select the Right Output
  • True RMS technology is accurate on distorted waveforms like those associated with VFD or SCR outputs
  • Average Responding for use with linear, sinusoidal waveforms
    Three Jumper Selectable Ranges
  • Reduces inventory
  • Eliminates zero and span pots
    Isolation
  • Magnetic isolation improves safety for installers and systems
    Easy Installation
  • Single piece with integral mounting brackets makes for a simple, solid installation
    UL, CUL and CE Approval
  • Accepted worldwide
Product Options:
$250.00

Secured and trusted checkout with

'AT/ATR 3 & 4' transducers from NK Technologies combine a high capacity current transformer and a signal conditioner into a single package for applications from 200A to 2000A. The AT version is Average Responding for use on linear (sinusoidal) loads. The ATR version is True RMS for use on distorted waveforms found in VFD or SCR outputs. Available in a solid-core case.

Selecting the right transducer: 

The current waveform of a typical linear load is a pure sine wave. AT transducers measure the peaks of these sine waves, then calculate the average amperage.  This works well on constant speed linear loads in a “clean” power environment.  Select AT transducers for strictly linear loads on “clean” power.  VFD and SCR output waveforms are rough approximations of a sine wave.  There are numerous spikes and dips in each cycle. ATR Transducers use a mathematical algorithm called “True RMS,” which integrates the actual waveform over time. The output is the amperage component of the true power (heating value) of the AC current waveform. True RMS is the only way to accurately measure distorted AC waveforms. Select ATR transducers for nonlinear loads on “noisy” power.

NK Technologies AT/ATR 3 & 4 Series Average Responding or True RMS AC High Current Transducers, Jumper Selectable Input Ranges, 4 - 20 mADC Output

Output Signal4–20 mA, Loop-powered
Output Limit23 mA
Accuracy1.0% FS accuracy, True RMS
MeasurementTrue RMS or Average Responding
Response Time600 ms (to 90% step change)
Frequency Range• ATR: 10–400 Hz
• AT: 50–60 Hz, Sinusoidal
Power Supply24 VDC Nominal, 12–40 VDC
Isolation Voltage600 VAC
Input Ranges• AT/ATR2: 100, 133, 200 A
• AT/ATR3: 375, 500, 750 A
• AT/ATR4: 1000, 1333, 2000 A
Sensing Aperture3.0” (76.2 mm) dia.
CaseUL94 V0 Flammability Rated
Environmental-4 to 122°F (-20 to 50°C)
0–95% RH, non-condensing
ListingsUL 508 Industrial Control Equipment
(USA & Canada), CE