We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The DL369 G2 Phoenix Clamp Meter Series offers the highest combination of functions, features, and safety offered in a meter today.
Range | Resolution | Accuracy | Overload |
DC Volts | |||
400mV 4V 40V 400V 1000V | 0.1mV 1mV 10mV 100mV 1V | ±0.5% + 4 ±0.8% + 10 | 600V |
AC Volts | |||
4V 40V 400V 1000V | 1mV 10mV 100mV 1V | ±0.75% + 3 | 600V |
DL389: 45Hz to 400Hz True RMS (Crest factor<3:1) | |||
AC Amps Measurement - Jaw Input (45~400Hz) | |||
40A 400A | 0.01A 0.1A | ±2.9% + 15 ±1.9% + 8 | 600V |
DL369: 400A range only DL389: 45Hz to 400Hz True RMS (Crest factor<3:1) | |||
DC Low Amps Measurement (Test Lead Input) | |||
400μA 2000μA | 0.01μA 0.1μA | ±1.2% + 3 | 2000μA/600V |
AC Low Amps Measurement (Test Lead Input) | |||
400μA 2000μA | 0.01μA 0.1μA | ±2.0% + 5 ±1.5% + 5 | 2000μA/600V |
DL389: 45Hz to 400Hz True RMS (Crest factor<3:1) | |||
Resistance | |||
400Ω 4kΩ 40kΩ 400kΩ 4MΩ 40MΩ | 100mΩ 1Ω 10Ω 100Ω 1kΩ 10kΩ | ±1.0% + 4 ±2.0% + 4 | 600V |
Capacitance Measurement | |||
40nF 400nF 4μF 40μF 400μF 4000μF | 0.01nF 0.1nF 0.001μF 0.01μF 0.1μF 1μF | ±3.5% + 6 | 600V |
Diode Test | |||
Range | Open Circuit V | Test Current | Overload |
2.0V | <3.0V DC | 0.25mA | 600V |
Frequency Measurement | |||
9.999Hz 99.99Hz 999.9Hz 9.999kHz 99.99kHz | 0.001Hz 0.01Hz 0.1Hz 1Hz 10Hz | ±0.1% + 4 | 600V |
Temperature Measurement (DL379 & DL389 ONLY) | |||
-22˚ ~ 14˚F (-30˚ ~ -10˚C) 15˚ ~ 752˚F (-9˚ ~ 400˚C) | 0.1˚F (0.1˚C) 0.1˚F (0.1˚C) | ±5.4˚F (±3.0˚C) ±1.0% + 3.6˚F (±1.0% + 2.0˚C) | 30V |
Duty (%) Cycle Measurement | |||
Range | Accuracy | Overload | |
01. to 99.9% | ±(0.2% per kHz +0.1%) + 5 | 600V | |
Continuity Measurement | |||
Open Circuit Voltage <2.7V | Overload | ||
Threshold Approximately <20Ω | 600V |