Setra 267MR Multi-Range Low Differential Pressure Transducer

SKU
267MR-2671
Manufacturer:
Setra Systems
Setra Systems

Key Features:

  • 6 Field Selectable Ranges
  • 2 Field Selectable Outputs
  • NEMA 4 Rated Housing
  • PG-9, PG-13 or Conduit Electrical Termination
  • Integral Static Pressure Probe
  • 24 VAC or 24 VDC Excitation
  • Meets CE Conformance Standards
Product Options:
$563.29

Secured and trusted checkout with

The 267MR multi-range low differential pressure transducer from Setra boasts top multi-range ability. The transducer provides users with 6 selectable ranges and 2 selectable outputs that, by flipping the Dip Switch, can be easily configured. With a pressure range of 0.1” W.C to 100” W.C, the 267MR assures ±0.25%, ±0.4% and ±1% FS accuracy.

 

Designed and manufactured by Setra themselves, the capacitive sensing element is crafted from all stainless steel. The welded dead-ended capacitive sensors need only marginal amplification and dispense superior accuracy and long-term stability.

 

Versatility is a key feature of the 267MR, available in both wall and duct mounting  options. The exterior of the 267MR is structured to sustain the most demanding work environments with its NEMA 4 rated housing, making the 267MR ideal for a variety of needs.

Performance Data

Physical Description

 

Standard

Optional

Case

IP65/NEMA 4 Plastic Glass-Filled

Polycarbonate UL94V-O Case

Accuracy RSS1

(at constant temp)

±1.0% FS

±0.4% FS

±0.25% FS

Electrical Connection

Screw Terminal Strip Inside of Case

Non-Linearity,  BFSL

±0.98% FS

±0.38% FS

±0.22% FS

Electrical Terminations

PG-9/PG13.5 Strain Relief, 1/2” Conduit

Opening, or 9 Pin D-Sub Connector*

Hysteresis

±0.10% FS

±0.10% FS

±0.10% FS

Zero and Span Adjustments

Accessible Inside of Case

Non-Repeatability

±0.5% FS

±0.5% FS

±0.5% FS

Weight (approx.)

9.0 Ounces (255 grams)

9.5 Ounces (Duct Probe Assembly)

Position Effect: Consult factory

Electrical Data (Current)

Pressure Media

Circuit

2-Wire, Protected from Miswiring

Thermal Effects2,3

Output4

4 to 20 mA5

Compensated Range °F (°C)

+40 to +150 (+5 to +65)

Bidirectional Output at Zero

12 mA

Zero/Span Shift %FS/°F (°C)

±0.033 (±0.06)

Min. Loop Supply Voltage (VDC)

9 + 0.02 x (Resistance of Receiver plus line)

Maximum Line Pressure

10 PSI

Max. Loop Supply Voltage (VDC)

30 + 0.004 x (Resistance of Receiver plus line)

Overpressure

Up to 10 PSI (Range Dependant)

Re-Ranging

5 Position Dip Switches (Located Inside Case)

Long-Term Stability

0.1% FS Total

Electrical Data (Voltage)

Environmental Data

Circuit

3-Wire  (Exc, Gnd, Sig), Protected from Miswiring

Operating6 Temperature °F (°C)0 to +150 (-18 to +65)

Excitation (for 0-5 VDC Output)

9 to 30 VAC /12 to 40 VDC

Storage Temperature °F (°C)

-65 to +180 (-54 to +82)

Excitation (for 0-10 VDC Output)

11 to 30 VAC /13 to 40 VDC

1 RSS of Non-Linearity, Hysteresis, and Non-Repeatability.
2 Units calibrated at nominal 70˚F. Maximum thermal error computed from
this datum.
3 Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater.
4 Zero output factory set to within ±0.16 mA (±0.08 mA for optional accuracies).
Span (Full Scale) output factory set to within ±0.16 mA (±0.08mA
for optional accuracy).
5 Zero output factory set to within ±50mV (±25 mV for optional accuracies).
Span (Full Scale) output factory set to within ±50mV (±25 mV for optional
accuracies
6 Operating temperature limits of the electronics only. Pressure media
temperatures may be considerably higher.
7 Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load.

Output (Field Selectable)

0 to 10 VDC7

Bidirectional Output at Zero

Mid-Range of Specified

Output Impedance

Ohms

Re-Ranging

5 Position Dip Switches (Located Inside Case)

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • HVAC Systems
  • Energy Management Systems
  • Static Duct Pressure
  • Cleanroom Pressure