Setra 206 Industrial Pressure Transducer

SKU
2061
Manufacturer:
Setra Systems
Setra Systems

Key Features:

  • Long-Term Stability: <0.5%/Year
  • Exceptional EMI/RFI
  • Rugged Design Withstands High Shock & Vibration
  • User Accessible Zero/Span
  • Calibration NIST Traceable
  • Wide Operating Voltage 12 VDC to 28 VDC
  • Meets CE Conformance Standards
  • Reverse Wire Protection
Product Options:
$379.20

Secured and trusted checkout with

Setra’s 206 is the solution to OEM customers in need of a top performing, reliable and versatile pressure sensor at an reasonable price. Covering a pressure range, as low as 25 PSI up to 10,000 PSI, the 206 provides a superior accuracy of ±0.13% FS.

 

Designed on the premise of precision and accuracy, the 206 is physically constructed for a range of demanding applications. Made with all stainless steel wetted materials, the pressure sensor is manufactured to satisfy NEMA4 and IP65 environmental ratings.

 

Setra’s 206 is equipped with numerous pressure and electrical connections making it adaptable to a range of installation configurations, while its zero and span potentiometers allow for calibration in the field.

For Cable Length Longer than 25' Please Call

Performance Data

Physical Description

Accuracy RSS1

(at constant temperature)

±0.13% FS

Pressure Fittings

See Ordering Information in the Data Sheet

Non-Linearity,  (BFSL)

25 PSIG range2

±0.1% FS

±0.2% FS

Vent

Through cable or terminal

Hysteresis

0.08% FS

Electrical Connection

2 ft. multiconductor cable

Non-Repeatability

0.02% FS

Case

Stainless Steel

Response Time

5 milliseconds

Zero/Span Adjustments

Top External Access

Long Term Stability

0.5% FS/1 YR

Weight (approx.)

6 oz

Thermal Effects

Electrical Data (Voltage)

Compensated Range

-4 to +176°F (-20 to +80ºC)

Excitation/Output

12 to 28 VDC

Reverse Excitation Protected

Zero Shift

±1% FS/100°F (±0.9% FS/50°C)

Power Consumption

<0.15 watts

(approx. 5mA @24VDC)

Span Shift

±1.5% FS/100°F (±1.4% FS/50°C)

Output8

0.1 to 5.1 VDC9

Pressure Media

Output Impedance

100 ohms

Gases or liquids compatible with 17-4 PH Stainless Steel.3

Circuit

3-Wire (Exc, Out, Com)

Environmental Data

Vibration11

200g Operating

Temperature

Electrical Data (Current)

   Operating4

-40 to +185°F (-40 to +85ºC)

Circuit

2-Wire

   Storage

-40 to +185°F (-40 to +85ºC)

Output10

4 to 20 mA11

Acceleration

10g Maximum5

External Load

0 to 800 ohms

Shock6

200g Operating

Min. Supply Voltage (VDC) = 9 +0.02 x (Resistance of receiver plus line)

Vibration7

20g 50-2000 Hz

1 RSS of Non-Linearity, Non-Repeatability and Hysteresis
2 25 PSIG range accuracy is ±0.22% of Full Scale output
3 Hydrogen not recommended for use with 17-4 PH stainless steel.
4 The high temperature limit of the cable is 200ºF (95ºC)
5 Shift in output reading <0.05 psi/g typical; pressure port axis only
6 Mil-Std. 202, Method 213B, Cond. C
7 Mil-Std. 202, Method 204, Cond. C
8 Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater
9 Zero output factory set to w/in ±25mV. Span (FS) output factory set to w/in ±50mV.
10 Calibrated at factory with a 24VDC loop supply voltage and 250ohm load.
11 Zero output factory set to w/in ±0.08mA. Span (FS) output factory set to w/in
±0.16mA.

Max. Supply Voltage (VDC) = 30 + 0.004 x (Resistance of receiver plus line)

 

 

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Industrial OEM Equipment
  • Hydraulic Systems
  • Compressor Control
  • HVAC/R Equipment
  • Industrial Engines