We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Delivering precision results in less than three seconds, Megger is offering their DLRO10 1006-598 Digital Low Resistance Ohmmeter. The DLRO10 1006-598 chooses the most apt test current, up to 10A DC to measure resistance from 0.1µΩ to 2000Ω on one of the seven ranges. The ohmmeter is equipped with a Normal, Auto, Continuous and Inductive Measurement Modes. Utilizing forward and reverse current, the average of the measurements attained is displayed to a basic accuracy of 0.2%.
The DLRO10 1006-598 is suited with an expansive, vivid 4 1/2 digit LED display for the best visibility in all lighting conditions. Megger has supplied the instrument with a pair of duplex handspikes with 1.2 m (4 ft) leads for user safety and an interchangeable NiMH battery pack for efficiency. Automatic continuity detection, visible alerts of high voltages and current flowing in the test sample and an array of other features and functions all make Megger’s DLRO10 1006-598 a leading example in low resistance measurement.
Measurement mode | DLRO 10: Manual, Auto, Continuous, Inductive DLRO 10X: Manual, Auto, Continuous, Inductive, Undirectional |
Measurement control | DLRO 10: Fully Automatic DLRO 10X: Fully Automatic/Manual |
Measurement speed | <3s for forward and reverse current and to display average |
Display Measurement | DLRO10: 4 1/2 digit seven segment LED DLRO10X: Large colour display |
Range and safety | DLRO10 LED indications |
Test method | Single cycle reversing d.c. ratiometric measurement - average result display. |
Test current accuracy | ±10% |
Test current stability | <10 ppm per second |
Lead resistance | Maximum 100 mΩ total for 10 A operation irrespective of battery condition. |
Voltmeter input impedance | >200 kΩ |
Noise rejection | Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning will show if hum or noise exceeds this level. |
Data transfer | DLRO10X: Real Time or from storage via RS232 |
Data storage | DLRO10X: 700 tests |
Memo field | DLRO10X: Up to 200 characters per test via integral alphanumeric keypad |
Battery type | 5.2 lithium ion rechargeable |
Battery life | Typical 1300 x 10 A tests before recharge |
Battery charge time | Via external 90 V - 260 V 50/60 Hz charger from 12 to 15 V dc supply Standard: 2.5 hours to 90% capacity, 4 hours to fully charged Slow Charge: +10 °C to + 45 °C (50 °F to 113 °F) |
Operating temperature range and humidity | +5 °C to +45 °C (41 °F to 113 °F) at full accuracy -10 °C to +50 °C (14 °F to 122 °F) at reduced accuracy <90% RH @ 40 °C (104 °F) non-condensing |
Storage temperature range and humidity | -30 °C to +70 °C (50 °F to 113 °F) <90% RH @ 40 °C (104 °F) non-condensing |
Temperature co-efficient | <0.01% per °C, over range 5 °C to 40 °C (<0.0006% per °F from 41 °F to 104 °F) |
Maximum altitude | 2000m (6562 ft) to full safety specifications |
Safety | In accordance with IEC61010-1, CAT III 600 V - only when DH6 leads are used. |
EMC | IP65 case closed, IP54 battery operation In accordance with IEC61326-1 (Heavy industrial) |
Dimensions | 220 x 100 x 237 mm |
Weight | 2.6 kg including battery |
* The accuracy stated assumes forward and reverse measurements. Inductive mode or undirectional mode will introduce an undefined error if an external EMF is present. |
- • Switch and Contact Breaker Resistance
- • Graphite Electrodes
- • Busbar and Cable Joints
- • Metal Alloys, Welds and Fuse Resistance
- • Aircraft Frame Bonds
- • Rails and Pipe Bonds
- • Static Control Circuits
- • Transformer and Motor Winding Resistance
- • Integrity of Welded Joints
- • Resistive Components Quality Control
- • Inter-Cell Connections on Battery Systems