Megger MIT410/2 1004-735 Insulation Tester with PI and DAR

SKU
1004-735
Manufacturer:
Megger
Megger

Key Features:

  • Test voltages of 50V, 100V, 250V, 500V and 1000V and 200GΩ range
  • Stabilized test voltage maintains specification through full test range
  • Test voltage accuracy of 2%
  • Polarization Index (PI) function: 10 min/ 1 min ratio
  • Dielectric Absorption Ratio (DAR) function: 60 sec/ 30 sec ratio
  • Timed testing to automatically test to a designated time limit
  • Entirely automatic single resistance range from 0.01Ω to 1.0MΩ for rapid testing
  • 600V TRMS AC and DC voltage measurement
  • Live circuit recognition and protection
  • Auto polarity (setup on-off)
  • 15-400 Hz frequency measurement ability
  • Pass/Fail on limit alarms
  • CAT IV 600 & IP54 rated
Product Options:
$1,100.00

Secured and trusted checkout with

Megger’s MIT410/2 1004-735 Insulation Tester offers all the capabilities of the MIT400/2 1006-719, with serval added features and functions.

 

The MIT410/2 1004-735 provides test voltages of 50V, 100V, 250V, 500V and 1000V and functions for Polarization Index (PI) and Dielectric Absorption Ratio (DAR). Likewise, the tester can perform frequency measurements from 15 to 400 Hz. The MIT410/2 1004-735 is outfitted with Pass/Fail on limit alarms and supplied with a switched probe for a total value.

All quoted accuracies are at +20 °C.
Insulation:
Test voltage
Nominal:
MIT400/2

250 V, 500 V, 1000 V
MIT410/2, 420/2, 430/250 V, 100 V, 250 V, 500 V, 1000 V
Insulation accuracy
50 Volts.10 GΩ± 2%± 2 digits ± 4.0% per GΩ
100 Volts.20 GΩ± 2%± 2 digits ± 2.0% per GΩ
250 Volts.50 GΩ± 2%± 2 digits ± 0.8% per GΩ
500 Volts.100 GΩ± 2%± 2 digits ± 0.4% per GΩ
1000 Volts200 GΩ± 2%± 2 digits ± 0.2% per GΩ
Service Error: BS EN 61557-2 (2007).
50V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 10.5%
100V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 10.3%
250V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 10.3%
500V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 10.3%
1000V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 11.5%
Display rangeAnalogue: 1 GΩ full scale
Resolution0.1 kΩ
Short circuit/charge current2 mA +0% -50% to EN 61557-2 (2007)
Open circuit voltage insulation-0% +2% ± 2V
Test current1 mA at min. pass value of insulation to a maximum of 2 mA max.
Leakage (not MIT400/2)10% ±3 digits
Voltage3% ±3 digits ±0.5% of rated voltage
Timer control (not MIT400/2)60 second countdown timer
NoteAbove specifications only apply when high quality silicone leads are being used.
Continuity:
Continuity measurement0.01 Ω to 1000 kΩ
Continuity accuracy± 3% ± 2 digits (0 to 100 Ω )
±5% ±2 digits (100 to 500kΩ)
(500kΩ to 1MΩ unspecified)
Service Error: BS EN 61557-4 (2007) - ± 2.0%, 0.1 Ω - 2 Ω ± 6.8%
Open circuit voltage5 V ± 1 V
Test current200 mA (–0 mA +20 mA) (0.01 Ω to 4 Ω)
Polarity (not MIT400/2)Single polarity (Default) / Dual polarity (configurable on setup).
Lead resistanceNull up to 9.00 Ω
Voltage:
Voltage rangeAC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz) DC: 0 to 600 V
Volt range accuracyAC: ±2% ±1 digit
DC: ±2% ±2 digit
Service Error: BS EN 61557-1 (2007) - ± 2.0% ± 2d, 0 V – 300 V AC/DC ± 5.1%
WaveformUnspecified range: 0 – 10 mV (15 to 400 Hz)
For non-sinusoidal waveforms additional specifications apply Non-sinusoidal waveforms: ±3% ± 2 digits >100 mV to 600 V TRMS ±8% ± 2 digits 10 mV to 100 mV TRMS
Frequency: (not MIT400/2)
Frequency measurement range15 Hz - 400 Hz
Frequency measurement accuracy±0.5% ± 1digit (100 Hz to 400 Hz unspecified)
Capacitance measurement:MIT420/2, MIT430/2
MIT420/2, MIT430/2
Capacitance measurement

1 nF to 10 μF
Capacitance measurement accuracy± 5.0% ± 2 digits (0.1 nF – 1 nF unspecified)
Storage:
Result storage (MIT420/2 and MIT430/2):
Storage capacity>1000 test results
Data download (MIT430/2 only)Bluetooth® wireless
Bluetooth® Class II
Rangeup to 10 m
Power supply6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline 6 x 1.2 V NiMH rechargeable cells may be used
Battery life3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
Charger (Optional):12-15 V dc (accessory interface)
DimensionsInstrument 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in)
Weight600 g (MIT400/2), (1.32 lb)
Weight (instrument and case)1.75 kg (3.86 lb)
FuseUse only 1 x 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 30 kA minimum. Glass fuses MUST NOT be fitted.
Safety protectionThe instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
EMCIn accordance with IEC 61326 including amendment No.1
Temperature co-efficient<0,1% per °C up to 1 GΩ
<0.1% per °C per GΩ above 1 GΩ
Environmental:
Operating temperature range and humidity-10 to +55 °C
90% RH at 40 °C max.
Storage temperature range-25 to +70 °C
Calibration temperature+20 °C
Maximum altitude2000 m
IP ratingIP 54
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc and is used under licence.

 

Data Sheet

Megger MIT410/2 Data Sheet

Manuals

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • • Battery Powered Traction and Lifting Equipment
  • • Commercial Avionics
  • • Cable Testing
  • • Military Land, Marine and Air Communications
  • • Component Testing
  • • Manufacturing/Production Line Goods
  • • Electrostatic Measurement
  • • Motoring Testing
  • • ESD
  • • Panel Building

Products In This Series