INOR IPAQ-H/-HX Programmable Transmitter - DISCONTINUED

SKU
70IPH
Manufacturer:
Inor Transmitter
Inor Transmitter

Key Features:

This Product is DISCONTINUED
Please see the INOR IPAQ C330, C330X (ATEX), and C330X (FM) as the Recommended Replacements

  • Excellent stability
  • Long-term stability 0.1 %/year
  • Enhanced total system accuracy
  • Sensor error correction (for known sensor errors)
  • System error correction (against known temperatures)
  • NAMUR-compliant
  • Output limitations and fail currents (according to NAMUR recommendations.)
  • Input-Output isolation 1500 VAC
  • Eliminates measuring errors due to ground loops
  • High load capacity
  • Only 6.5 V voltage drop over the transmitter (IPAQ-H) allows for high loads
  • Designed for harsh conditions
  • Operation temperature: -40 to +85 °C, -40 to +185 °F
  • Excellent EMC performance
  • Durable, shockproof design
  • Simple mounting and connection for DIN B head or larger
  • Large center hole (dia. 7 mm / 0.28 inch)
  • 5 year limited warranty
Call For Price

Secured and trusted checkout with

IPAQ-H/-HX are universal, isolated 2-wire transmitters for temperature and other measurement applications. They combine competitive pricing, functionality and simple configuration. Useful error correction functions improve the accuracy.

IPAQ-HX is the Intrinsic Safe version for use in Ex-applications.

Functions

  • • Input for RTDs, T/Cs, mV and resistance
    Reduced inventory costs.
    Simplified plant engineering.
  • True on-line communication
    Full access to all features while in operation.
  • Sensor diagnostics
    SmartSense detects low sensor isolation (essential for correct measurements).
    Selectable sensor break action.
  • Simplified loop check-up
    The transmitter works as an accurate current generator.
  • On-screen indications and line recording
    Valuable tools for temporary measurements.

 

INOR IPAQ-H: In-head, multifunction, on-line PC-configuration, isolation 1500VAC

INOR IPAQ-HX (FM): In-Head, multifuction, on-line PC-configuration, isolation 1500VAC, FM/CSA Approval

INOR IPAQ-HX (ATEX): In-Head, multifuction, on-line PC-configuration, Demko 02 ATEX 132033, Ex II 1G  EEx ia IIC T4-T6

INOR Configuration Kit (Complete Package, except HART modem)

  • INOR USB Interface
  • Adapter Cables
  • Software on Flashdrive
  • Works with Windows 2000 through 8.1

 

Configuration

  • PC Programmable

Input

RTD’s and Resistance

Pt100 (IEC751, α = 0.00385)

3-, 4-wire connection                             -200 to +1000 °C / -328 to +1832 °F

Pt1000 (IEC751, α = 0.00385)

3-, 4-wire connection                             -200 to +200 °C/ -328 to +392 °F

PtX 10 ≤  X ≤ 1000 (IEC751, α = 0.00385)

3-, 4-wire connection                             Upper range depending on X-value

Ni100 (DIN 43760)

3-, 4-wire connection                             -60 to +250 °C / -76 to +482 °F

Ni1000 (DIN 43760)

3-, 4-wire connection                             -60 to +150 °C / -76 to +302 °F

D100 (Pt 100 acc.to JIS1604, α = 0.003916)

3-, 4-wire connection                             -200 to +1000 °C / -328 to +1832 °F

Potentiometer/resistance

3-, 4-wire connection                              0 to 2000 Ω

Sensor current

~ 0.4 mA

Maximum sensor wire resistance

25  Ω/wire

Thermocouples and Voltage

T/C

Type: AE, B, E, J, K, L, N, R, S, T, U      Ranges according to users manual

Voltage input

-10 to +500 mV

Input impedance

                                                               >10 MΩ

Maximum sensor wire resistance

500 Ω (total loop)

Monitoring

Sensor break monitoring

User definable output                             3.5 to 21.6 mA

SmartSense, sensor isolation monitoring

User definable output                             3.5 to 21.6 mA

Adjustments

Zero adjustment

All inputs                                              Any value within range limits

Minimum spans

Pt100, Pt1000, Ni100, Ni1000         10 °C / 18 °F

 

Potentiometer                                      10Ω

 

T/C, mV                                                2 mV

Output

Straight,reversed or any intermediate value

4-20/20-4 mA

Resolution

5  µA

Minimum output signal

Measurement/Failure                        3.8 mA / 3.5 mA

Maximum output signal

Measurement/Failure                        20.5 mA / 21.6 mA

Permissible load

IPAQ-H                                                   795 Ω @ 24 VDC, 22 mA

 

IPAQ-HX                                                725 Ω @ 24 VDC, 22 mA

Temperature

Ambient, storage

-40 to +85 °C / -40 to +185 °F

Ambient, operation

IPAQ-H                                                   -40 to +85 °C / -40 to +185 °F

 

IPAQ-HX                                                See Intrinsic Safety specifications

General data

Selectable dampening time

~ 2 s

Update time

~ 1.5 s

Isolation In - Out

Isolated version                                    1500 VAC, 1 min

Humidity (non-condensing)

0 to 95 %RH

Intrinsic safety

IPAQ-HX, ATEX                                          II 1 G EEx ia IIC T4, T5, T6

 

FM                                          Class I, Div. 1, Group A-D, T4

Power supply, polarity protected

Supply voltage

IPAQ-H                                                  6.5 to 36 VDC    2-wire

 

IPAQ-HX                                                8.0 to 30 VDC    2-wire

Permissible ripple

4 V p-p @ 50/60 Hz

 

Accuracy

Linearity

RTD Potentiometer, mV                            ±0.1 % 1)

 

T/C                                                         ±0.2 % 1)

Calibration

RTD                                                     Max. of ±0.2 °C / ±0.4 °F or ±0.1 %1)

 

Potentiometer                                    Max. of ±0.1 Ω or ±0.1 %1)

 

mV, T/C                                                Max. of ±20 µV or ±0.1 %1)

Cold Junction Compensation (CJC)

T/C                                                         ±0.5 °C / ±0.9 °F

Temperature influence 4)

All inputs                                            Max. of ±0.25 °C/25 °C or ±0.25%/25 °C1) 3)

 

Max. of ±0.5 °F/50 °F or ±0.28%/50 °F1) 3)

Temperature influence CJC 4)

T/C                                                         ±0.5 °C/25 °C / ±1.0 °F/50 °F

Instrument calibration output

4-20 mA                                                ±8 µA

Sensor wire resistance influence

RTD, Potentiometer, 3-wire                    Negligible 2)

 

RTD, Potentiometer, 4-wire                    Negligible

 

mV, T/C                                                Negligible

Load influence

Negligible

Power supply influence

Negligible

RFI influence, 0.15 to 1000 MHz, 10 V or V/m

                                                              ±0.1% 1)   (typical)

Long-term stability

                                                              ±0.1 % 1) /year

Housing

Material / Flammability (UL)

PC + ABS/V0, Polyamide/V2

Mounting

DIN B-head or larger, DIN rail (with mounting kit)

Connection

Single/stranded wires                         ≤1.5 mm2, AWG 16

Weight

50 g

Protection, housing / terminals

IP 50 / IP 10

1) Of input span

2) With equal wire resistance

3) If zero-deflection > 100% of input span:

add 0.125% of input span/25 °C or 0.14%

of input span/50 °F per 100% zero-deflection

4) Reference temperature 23 °C / 73 °F

 

Intrinsic Safety Specifications

Specifications

IPAQ-HX, isolated                                                 IPAQ-HX, isolated

Approval

Demko / ATEX                                                         Factory Mutual (FM)

Classification

II 1 G  EEx ia IIC T4-T6                                            IS for use in Class I, Div. 1,

 

T4/+85 °C, T5/+65 °C, T6/+50 °C                                 Group A-D, T4/+80 °C

Certificate No.

DEMKO 02 ATEX 132033                                            J.I. 0D6A8.AX, Dr w. 3-7851

Output/Supply

Max voltage to transmitter

Ui = 30 Vdc                                                           Vmax = 30 Vdc

Max current to transmitter

Ii = 100 mA                                                             Imax = 100 mA

Max power to transmitter

Pi = 900 mW                                                           Pmax = 900 mW

Internal inductance

Li = 0 mH                                                               Li = 2.5 mH

Internal capacitance

Ci = 0 µF                                                                Ci = 0 µF

Input (Sensor)

Max voltage from transmitter

Uo = 30 Vdc                                                           Voc = 30 Vdc

Max current from transmitter

Io = 25 mA                                                             Isc = 25 mA

Max power from transmitter

Po = 188 mW                                                          Not specified

Max inductance (input loop)

Lo = 50 mH                                                            La = 56.8 mH

Max capacitance (input loop)

Co = 66 nF                                                             Ca = 0.12 µF