INOR IsoPAQ-110L 1 & 2-Channel Loop Powered Isolators

SKU
70ISC1100
Manufacturer:
Inor Transmitter
Inor Transmitter

Key Features:

  • Input to output galvanic isolation
  • Protection against erroneous measurements due to parasitic voltages or ground loops
  • 1- and 2-channel versions allows for optimal cost efficiency
  • No power supply required
  • Reduced wiring saves installation costs
  • Fixed ranges
  • Ready to use without any settings
  • Compact DIN-rail mounting
  • 11.2 mm (0.44”) housing combined with very low self heating allows for high density mounting. With a depth of only 60 mm, compact standard boxes can be used
  • Protective Separation
  • The design and high isolation level (2.5 kV) provides protection for service personnel and downstream devices against impermissibly high voltage
  • High accuracy
  • Negligible additional measurement errors in the loop
Product Options:
$177.00

Secured and trusted checkout with

IsoPAQ-110L is a loop powered isolator, available in 1- and 2-channel versions. It is used for electrical isolation of 0(4)-20 mA signals to avoid measurement errors due to different voltage potentials or ground loops in an instrument installation.

COMPACT LINE is a line of very compact and cost-optimized Isolators, Transmitter Repeaters and Isolating Transmitters within the IsoPAQ family.  The small dimensions - only 60 mm deep and 11.2 mm wide – and the favorable pricing allow for space saving and economic installations.

The isolator need no power supply, which contributes to reduced installation costs compared to Isolation Transmitters.  The high reliability ensures a safe system operation and low maintenance costs.

The 2-channel version, IsoPAQ-110L offers a very cost effective alternative combined with a high-density mounting.

Input
Input signal0(4)-20 m
Operating current< 100 μA
Voltage drop< 3 V
Overload≤ 50 mA, ≤ 15 V
Output
Output signal0(4)-20 mA
Load< 600 Ω
Response time
(10 to 90 % of end value)
5 ms @ 500 Ω load
Ripple< 0.1 % of end value, ~ 100 kHz
General data
Transmission error± 0.1 % of end value
Load error± 0.05 % of measured value/100 Ω load
Temperature coefficient 1)± 0.004 %/K of measured value/100 Ω load
Test voltage2.5 kV, 50 HzBetween all circuits
Working voltage 2) (Basic Insulation)

600 VAC/DC for overvoltage category II and pollution degree 2

acc. to EN 61010 part 1 between all circuits.

Protection against electrical
shock 2)
Protective separation acc. to EN 61140 by reinforced insulation acc. to EN 61010 part 1 up to 300 VAC/DC for overvoltage category II and pollution degree 2 between all circuits.
Ambient temperatureOperation
Transport and storage
0 to +55 °C (32 to +131 °F)
-25 to +80 °C (-13 to +176 °F)
EMC 3)EN 61326-1
Construction11.2 mm (0.44”) housing, protection class: IP20
Connection≤ 2.5 mm2, AWG 14
WeightApprox. 50 g

1) Average TC in specified operating temperature range
2) As far as relevant the standards and rules mentioned above are considered by development and production of our devices. In addition relevant assembly rules are to be  considered by installation of our devices in other equipments. For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance or insulation between adjacent situated devices.
3) Minor deviations possible during interference