GW Instek GDM-9061 6 1/2 (1200000 counts) Digit Dual Measurement Multimeter

SKU
GDM-9061
Manufacturer:
GW Instek
GW Instek

Key Features:

  • 6 1/2 Digit Display:1,200,000 Counts
  • 4.3 TFT Craphic LCD
  • DCV Basic Accuracy:0.0035%
  • 12 Measurement Functions: DCV, ACV, DCI, ACI, 2-wire and 4-wire Resistance, Frequency, Period, Diode, Continuity, Temperature and Capacitance
  • Sampling Rate up to 10k SPS
  • Dual Measurement Function to Providing Two Selected Measurement Simultaneously
  • Offer Graphical Capabilities lncluding Histogram, Bar Meter and Trend
  • Temperature Measurement Support RTD, Thermistor as Well as Thermocouple
  • Standard Interfaces: USB Host/Device, RS-232C, LAN, Digital I/O
  • Optional Interface: GPIB
Product Options:
$103.00

Secured and trusted checkout with

The GW Instek GDM-9061 is a 6 1/2 digit dual measurement multimeter with a DC voltage accuracy of 0.0035%. The GDM-9061 also features fast sampling rate, 12 measurement functions (DC voltage/current, AC voltage/current, 2-wire/4-wire resistance, frequency, period, diode, continuity beeper, temperature, capacitance), 6 mathematical functions (dB/dBm/Compare/ MX+B/Percent and 1/X) as well as a variety of communications interfaces (USB device/host, RS-232C, LAN, digital I/O and optional GPIB) to provide comprehensive measurement capabilities, higher speed and accuracy.

Function

Range (2)

Resolution

Input Resistance etc.

24 Hour

TCAL± 1°C

90 Day

TCAL± 5°C

1 Year

TCAL± 5°C

Temperature

Coefficient

0°~ 18°C /

28°~ 55°C

DC Characteristics                                                                      Accuracy  : ± (% of  reading  + % of range)

 

 

 

DC Voltage

(1)

100.0000 mV

0.1μV

10MΩ or >10GΩ

0.0030 + 0.0030

0.0040 + 0.0035

0.0050 + 0.0035

0.0005 + 0.0005

1.000000 V

1μV

10MΩ or >10GΩ

0.0020 + 0.0006

0.0035 + 0.0007

0.0048 + 0.0007

0.0005 + 0.0001

10.00000 V

10μV

10MΩ or >10GΩ

0.0015 + 0.0004

0.0020 + 0.0005

0.0035 + 0.0005

0.0005 + 0.0001

100.0000 V

0.1mV

10MΩ±1%

0.0020 + 0.0006

0.0035 + 0.0006

0.0050 + 0.0006

0.0005 + 0.0001

1000.000 V

1mV

10MΩ±1%

0.0025 + 0.0006

0.0040 + 0.0010

0.0050 + 0.0010

0.0005 + 0.0001

 

 

 

 

Resistance

(1)(3)

100.0000 Ω

100μΩ

1mA

0.003 + 0.0030

0.008 + 0.004

0.010 + 0.004

0.0008 + 0.0005

1.000000 kΩ

1mΩ

1mA

0.002 + 0.0005

0.008 + 0.001

0.010 + 0.001

0.0008 + 0.0001

10.00000 kΩ

10mΩ

100μA

0.002 + 0.0005

0.008 + 0.001

0.010 + 0.001

0.0008 + 0.0001

100.0000 kΩ

100mΩ

10μA

0.002 + 0.0005

0.008 + 0.001

0.010 + 0.001

0.0008 + 0.0001

1.000000 MΩ

5μA

0.002 + 0.0010

0.008 + 0.001

0.010 + 0.001

0.0010 + 0.0002

10.00000 MΩ

10Ω

500nA

0.015 + 0.0010

0.020 + 0.001

0.040 + 0.001

0.0030 + 0.0004

100.0000 MΩ

100Ω

500nA//10MΩ

0.300 + 0.0100

0.800 + 0.010

0.800 + 0.010

0.1500 + 0.0002

 

 

 

 

 

DC Current

(1)(6)

100.0000 μA

100pA

< 0.011 V

0.010 + 0.020

0.040 + 0.025

0.050 + 0.025

0.002 + 0.003

1.000000 mA

1nA

< 0.11 V

0.007 + 0.006

0.030 + 0.006

0.050 + 0.006

0.002 + 0.001

10.00000 mA

10nA

< 0.04 V

0.007 + 0.020

0.030 + 0.020

0.050 + 0.020

0.002 + 0.002

100.0000 m A

100nA

< 0.4 V

0.010 + 0.004

0.030 + 0.005

0.050 + 0.005

0.002 + 0.001

1.000000 A

1μA

< 0.7 V

0.050 + 0.006

0.080 + 0.010

0.100 + 0.010

0.005 + 0.001

3.000000 A

1μA

< 2.0 V

0.180 + 0.020

0.200 + 0.020

0.200 + 0.020

0.005 + 0.002

10.00000 A

10μA

< 0.5 V

0.100 + 0.010

0.120 + 0.010

0.150 + 0.010

0.005 + 0.001

Continuity (1)

1000.000 Ω

0.001Ω

1 mA

0.002 + 0.030

0.008 + 0.030

0.01 + 0.030

0.001 + 0.002

Diode Test (1)(4)

5.00000 V

10μV

1 mA

0.002 + 0.030

0.008 + 0.030

0.01 + 0.030

0.001 + 0.002

DC Ratio (1)(5)

―

―

―

± (DC Input accuracy + DC Reference accuracy)

 

AC Characteristics                                                                      Accuracy  : ± (% of  reading  + % of range)

 

 

 

 

 

 

 

 

True RMS AC Voltage (7)(8)(9)(10)

 

 

 

 

 

100.0000 mV

 

 

 

 

 

0.1μV

3Hz - 5Hz

1.00 + 0.03

1.00 + 0.04

1.00 + 0.04

0.100 + 0.004

5Hz - 10Hz

0.35 + 0.03

0.35 + 0.04

0.35 + 0.04

0.035 + 0.004

10Hz - 20kHz

0.04 + 0.03

0.05 + 0.04

0.06 + 0.04

0.005 + 0.003

20kHz - 50kHz

0.10 + 0.05

0.11 + 0.05

0.12 + 0.05

0.011 + 0.005

50kHz - 100kHz

0.55 + 0.08

0.60 + 0.08

0.60 + 0.08

0.060 + 0.008

100kHz -300kHz

4.00 + 0.50

4.00 + 0.50

4.00 + 0.50

0.200 + 0.020

 

 

 

 

1.000000 V to

750.000 V

 

 

 

 

1μV ~

1mV

3Hz - 5Hz

1.00 + 0.02

1.00 + 0.03

1.00 + 0.03

0.100 + 0.004

5Hz - 10Hz

0.35 + 0.02

0.35 + 0.03

0.35 + 0.03

0.035 + 0.004

10Hz - 20kHz

0.04 + 0.02

0.05 + 0.03

0.06 + 0.03

0.005 + 0.003

20kHz - 50kHz

0.10 + 0.04

0.11 + 0.05

0.12 + 0.05

0.011 + 0.005

50kHz - 100kHz

0.55 + 0.08

0.60 + 0.08

0.60 + 0.08

0.060 + 0.008

100kHz -300kHz

4.00 + 0.50

4.00 + 0.50

4.00 + 0.50

0.200 + 0.020

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

True RMS AC Current (6)(7)(9)(10)

 

 

100.0000 μA

10.00000 mA

 

 

< 0.011 V

< 0.04 V

3Hz – 5Hz

1.00 + 0.04

1.00 + 0.04

1.00 + 0.04

0.100 + 0.006

5Hz – 10Hz

0.35 + 0.04

0.35 + 0.04

0.35 + 0.04

0.035 + 0.006

10Hz – 5kHz

0.10 + 0.04

0.10 + 0.04

0.10 + 0.04

0.015 + 0.006

5kHz – 10kHz

0.18 + 0.04

0.18 + 0.04

0.18 + 0.04

0.030 + 0.006

 

 

1.000000 mA

100.0000 mA

 

 

< 0.11 V

< 0.4 V

3Hz – 5Hz

1.00 + 0.04

1.00 + 0.04

1.00 + 0.04

0.100 + 0.006

5Hz – 10Hz

0.30 + 0.04

0.30 + 0.04

0.30 + 0.04

0.035 + 0.006

10Hz – 5kHz

0.10 + 0.04

0.10 + 0.04

0.10 + 0.04

0.015 + 0.006

5kHz – 10kHz

0.15 + 0.04

0.15 + 0.04

0.15 + 0.04

0.030 + 0.006

 

 

 

1.000000 A

 

 

 

< 0.7 V

3Hz – 5Hz

1.00 + 0.04

1.00 + 0.04

1.00 + 0.04

0.100 + 0.006

5Hz – 10Hz

0.30 + 0.04

0.30 + 0.04

0.30 + 0.04

0.035 + 0.006

10Hz – 5kHz

0.10 + 0.04

0.10 + 0.04

0.10 + 0.04

0.015 + 0.006

5kHz – 10kHz

0.15 + 0.04

0.15 + 0.04

0.15 + 0.04

0.030 + 0.006

 

 

 

3.000000 A

 

 

 

< 0.2 V

3Hz – 5Hz

1.00 + 0.04

1.00 + 0.04

1.00 + 0.04

0.100 + 0.006

5Hz – 10Hz

0.35 + 0.04

0.35 + 0.04

0.35 + 0.04

0.035 + 0.006

10Hz – 5kHz

0.23 + 0.04

0.23 + 0.04

0.23 + 0.04

0.015 + 0.006

5kHz – 10kHz

0.23 + 0.04

0.23 + 0.04

0.23 + 0.04

0.030 + 0.006

 

 

 

10.00000 A

 

 

 

< 0.5 V

3Hz – 5Hz

1.10 + 0.04

1.10 + 0.04

1.10 + 0.04

0.100 + 0.006

5Hz – 10Hz

0.35 + 0.04

0.35 + 0.04

0.35 + 0.04

0.035 + 0.006

10Hz – 5kHz

0.15 + 0.04

0.15 + 0.04

0.15 + 0.04

0.015 + 0.006

5kHz – 10kHz

0.35 + 0.04

0.35 + 0.04

0.35 + 0.04

0.030 + 0.006

Frequency and Period Characteristics                                                                      Accuracy  : ± (% of  reading)

 

Frequency / Period (11)(12)(13)(14)

 

 

100.0000mV to

750.000V

 

 

 

―

3Hz - 5Hz

0.100

0.100

0.100

0.100

5Hz - 10Hz

0.050

0.050

0.050

0.035

10Hz - 40Hz

0.030

0.030

0.030

0.015

40Hz -1MHz

0.006

0.006

0.006

0.015

Temperature Characteristics

Temperature

(RTD) (15)

-200 °C ~ -100 °C

0.001 °C

―

―

―

0.09 °C

0.004 °C / °C

-100 °C ~ -20 °C

0.001 °C

―

―

―

0.08 °C

0.005 °C / °C

-20 °C ~ 20 °C

0.001 °C

―

―

―

0.06 °C

0.005 °C / °C

 

 

20 °C ~ 100 °C

0.001 °C

―

―

―

0.08 °C

0.005 °C / °C

100 °C ~ 300 °C

0.001 °C

―

―

―

0.12 °C

0.007 °C / °C

300 °C ~ 600 °C

0.001 °C

―

―

―

0.22 °C

0.009 °C / °C

 

 

 

 

 

Temperature (Thermocouples) (15)

-200 to +1000 °C

0.002 °C

E

―

―

0.2 °C

0.03 °C / °C

-210 to +1200 ËšC

0.002 °C

J

―

―

0.2 °C

0.03 °C / °C

-200 to +400 °C

0.002 °C

T

―

―

0.3 °C

0.04 °C / °C

-200 to +1372 ËšC

0.002 °C

K

―

―

0.3 °C

0.04 °C / °C

-200 to +1300 ËšC

0.003 °C

N

―

―

0.4 °C

0.05 °C / °C

-50 to +1768 ËšC

0.01 °C

R

―

―

1 °C

0.14 °C / °C

-50 to +1768 ËšC

0.01 °C

S

―

―

1 °C

0.14 °C / °C

+350 to +1820 ËšC

0.01 °C

B

―

―

1 °C

0.14 °C / °C

Temperature (Thermistor) (15)

–80 ° to 150 °C

0.01 °C

 

―

 

―

 

―

 

0.01 °C

 

0.003 °C / °C

Capacitance Characteristics                                                                      Accuracy  : ± (% of  reading  + % of range)

 

 

 

 

Capacitance

(16)

 

1.000 nF

 

―

 

2.00 + 2.00

 

2.00 + 2.00

 

2.00 + 2.00

 

0.05 + 0.01

 

2.00 + 2.00

 

10.00 nF

 

―

 

2.00 + 1.00

 

2.00 + 1.00

 

2.00 + 1.00

 

0.05 + 0.01

 

2.00 + 1.00

 

100.0 nF

 

―

 

2.00 + 0.40

 

2.00 + 0.40

 

2.00 + 0.40

 

0.05 + 0.01

 

2.00 + 0.40

 

1.000 μF

 

―

 

2.00 + 0.40

 

2.00 + 0.40

 

2.00 + 0.40

 

0.05 + 0.01

 

2.00 + 0.40

 

10.00 μF

 

―

 

2.00 + 0.40

 

2.00 + 0.40

 

2.00 + 0.40

 

0.05 + 0.01

 

2.00 + 0.40

 

100.0 μF

 

―

 

2.00 + 0.40

 

2.00 + 0.40

 

2.00 + 0.40

 

0.05 + 0.01

 

2.00 + 0.40

Display

4.3" color TFT WQVGA (480x272) with LED backlight

Interface

RS -232C,  USB host/device, LAN, Digital I/O; GPIB(optional)

Power Source

AC 100 V / 120 V / 220 V / 240 V ±10%

Power Line Frequency

50 Hz / 60 Hz and 400 Hz ±10%

Power Consumption

Max. 25VA

 

Dimensions

267(W) x 107(H) x 302(D) mm ~ with bumper

220(W) x 88 (H) x 277(D) mm ~ without bumper

Weight

Approx. 3.53kg without option

 

[1].  DC Specification: In addition to the availability that requires warm-up of 60 minutes, it must be set in 5/s speed rate (60/s speed rate for Continuity and Diode), A-Zero on.

[2].  The entire range of measurement will pass the set range by 20% except the tests of 1000 DCV, 750 ACV, 3 A DC, 3A AC, 10A DC, 10A AC and diode.

[3].  This specification applies to 4-wire resistance measurement, whilst it requires using "REL" function for offset on 2-wire resistance measurement. 2-wire resistance measurement will cause additional error of 0.2 Ω if REL function is not executed.

[4].  This specification applies to the voltage measured from input terminal. 1 mA test current is the typical value. The change of current source leads to the variation in buck of diode junction.

[5].  Accuracy is ± (DC Input accuracy + DC Reference accuracy), where Input accuracy = DC Voltage accuracy for the Input HI to LO (in % of the Input voltage), and Reference accuracy = DC Voltage accuracy for the HI to LO (Sense) Reference (in % of the Reference voltage).

[6].  The 10 A range of measurement is available for the terminals on front panel only. Due to power factor resulting in temperature rise, 2 mA increment per one ampere when input is greater than 5 A rms.

[7].  AC Specification: It will be available after 60 minutes of warm-up, sine wave as well as 1/s speed rate.

[8].  Specifications are for sinewave input >5% of range. For inputs from 1% to 5% of range and <50 kHz, add 0.1% of range additional error. For 50 kHz to 100 kHz, add 0.13% of range. The measurement range of 750 ACV is limited within the range of 7.5 x 10^7 Volt–Hz.

[9].  Three speed settings provided for low-frequency performance: 1/s (3 Hz), 5/s (20 Hz), 20/s (200 Hz). Additional errors will Not occur for the frequency greater than the filter settings.

[10]. Specifications are for sinewave input >5% of range, and is beyond 10 μA AC. For inputs from 1% to 5% of range, add 0.1% of range additional error.

[11]. This specification will be available after 60 minutes of warm-up and sine wave input, unless stated otherwise. This specification applies to 1s gate time.

[12]. This specification is available when both sine wave and square wave input ≥ 100 mV. For the input of 10 mV to 100 mV, the % of reading error needs to be multiplied by 10 times.

[13]. The amplitude range is from 10% to 120% and is lower than 750 ACV. [14]. The input ≥ 60 mV, for 300 k ~ 1 MHz, within 100mV range.

[15]. The actual measurement range and test lead error will be constrained by the adopted test lead. The test lead accuracy adder covers all errors of measurements and ITS-90 temperature change.

[16]. Specifications are for film Capacitance inputs that are greater than 10% range

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series