The GW Instek APS-7100 is part of the APS-7000 series of programmable linear AC power supplies. The maximum rated output for the APS-7100 is 1000VA, 310Vrms, 8.4Arms. The optional collocation can be extended to the maximum output voltage of 600Vrms and maximum output frequency of 999.9Hz.
It features nine different measurement and test functions (Vrms, Irms, F, Ipk, W, VA, PF, Ipk hold, CF), and provides user interface similar to that of an AC Power Meter. The APS-7100, by switching many sets of current levels to augment small current measurement resolution, is ideal for the LED industry and standby mode power consumption test. The APS-7100 supplies a stable source of AC and also features five methods to cope with special purpose or abnormal voltage, frequency, and phase; ten sets of the Simulate mode simulate power outage, voltage increase, and voltage drop; ten sets of the Sequence mode allow users to define parameters and produce sine wave by editing steps; ten sets of the Program mode can edit AC waveform output and define the ceiling and floor level of measurement items for different DUT; Ramp Control allows users to set the variation speed for output voltage rise and fall; Surge/Dip Control simulates DUT’s input power producing a Surge or Dip voltage overlapping with output voltage waveform at a specific time.
Model | APS-7050 | APS-7100 | |||
Maximum Output Capacity | |||||
Power Rating | 500VA | 1kVA | |||
Output Voltage Setting | |||||
Range | 0~155Vrms, 0~310Vrms, 0~600Vrms (APS-003), Auto | ||||
Output Maximum Current | |||||
Range | 4.2A/2.1A/1.05A (APS-003) | 8.4A/4.2A/2.1A (APS-003) | |||
OutputMaximumPeak Current | |||||
Range | 16.8A/8.4A/4.2A (APS-003) | 33.6A/16.8A/8.4A (APS-003) | |||
Output Frequency Setting | |||||
Range | 45.0~500Hz | 45~999.9Hz(APS-004) | 45.0~500Hz | 45~999.9Hz(APS-004) | |
Resolution | 0.01Hz(45.0~99.99Hz) | 0.01Hz(45.0~99.99Hz) | 0.01Hz(45.0~99.99Hz) | 0.01Hz(45.0~99.99Hz) | |
Setting Accuracy | ±(0.02% of setting) | ||||
Waveform | |||||
Total harmonic distortion | ≦0.5% at 45~500Hz (Resistive load) | ||||
Voltage Regulation | |||||
Line Regulation | 0.1% of full scale | ||||
Load Regulation | 0.5% of full scale | ||||
Measurement | |||||
Frequency | Range | 45~ 500Hz | |||
Resolution | 0.01Hz (45.0~99.99Hz) | ||||
Accuracy | ±0.1Hz | ||||
With APS-004 Option | Range | 45~ 999.9Hz | |||
Resolution | 0.01Hz (45.0~99.99Hz) | ||||
Accuracy | ±0.02% of setting | ||||
Voltage (r.m.s) | Range | 0.2~38.75 Vrms | |||
Resolution | 0.01V at 0.00~99.99 Vrms | ||||
Accuracy | ±(0.5% of reading+ 2counts) | ||||
With APS-003 Option | Range | 0.2~600Vrms | |||
Resolution | 0.01V at 0.00~99.99 Vrms | ||||
Accuracy | ±(0.5% of setting+ 2counts) | ||||
Current (r.m.s) | Range | 2.00~70.00mA | |||
Resolution | 0.01mA | ||||
Accuracy | ±(0.6% of reading+5 counts), 2.00~350.0mA | ||||
Power (W) | Resolution | 0.01W | |||
Accuracy | ±(0.6% of reading+5 counts), 0.2~99.99W | ||||
Power Factor | Resolution | 0.001 | |||
Accuracy | ±(2% reading+ 2 counts) | ||||
Crest Factor | Range | 0.00~50.00 | |||
Resolution | 0.01 | ||||
General | |||||
Remote Output Signal | Pass, Fail, Test-in Process, Trigger in, Trigger out ,Out ON/OFF | ||||
Sync Signal Socket | Output Signal 10V, BNC type | ||||
Interface | USB Host, LAN | ||||
Output Mode | |||||
Memory | 10 (0~9 numeric keys) | ||||
AC Input | 115/230 Vac±15% | ||||
Others | |||||
Phase | Single Phase, Two wire (1P2W) | ||||
Protection | OCP, OPP, OHP and Alarm | ||||
Dimension (W*H*D) & Weight | 430x88x400, 24Kg | 430x88x560, 38Kg |