Fluke 117 DMM / PRV240 Proving Unit Kit

SKU
FLUKE-117/PRV240
Manufacturer:
Fluke
Fluke

Key Features:

Fluke 117 Electrician’s Multimeter with Non-Contact Voltage

  • VoltAlert™ technology for non-contact voltage detection
  • AutoVolt automatic AC/DC voltage selection
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True RMS for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30-seconds)
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
  • CAT III 600 V safety rated

 

Fluke PRV240 Proving Unit

  • Sources both ac and dc steady-state voltage - supplies 240 V dc/ac
  • A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
  • Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
  • Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
  • Includes Magnetic Hanging Strap
  • Long battery life - 5,000 tests per set of four AA batteries
Special Price $391.49 Regular Price $434.99

Secured and trusted checkout with

The Fluke 117 DMM / PRV240 Kit includes a Fluke 117 Electrician's Multimeter with Non-Contact Voltage and a Fluke PRV240 Proving Unit.

Fluke 117 Electrician’s Multimeter with Non-Contact Voltage

Specifications
Maximum voltage between any terminal and earth ground600 V
Surge protection6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Battery type9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
OhmsRange/resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode testRange/resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/resolution> 1000 μF
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A continuous overload for 30 seconds max
DC ampsRange/resolution

6.000 A / 0.001 A   10.00 A / 0.01 A

Accuracy1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

 

Fluke PRV240 Proving Unit

Output voltage

240 V ac rms or dc

±10 % ≥1 MΩ

LoZ >3 kΩ load

60 V ac typical
50 V ac rms minimum

LED power indicator

Turns on when output voltage is present

Battery

4 x AA Alkaline batteries NEDA

24 A IEC LR03

Battery life

5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load

Operating temperature

-10 °C to +50 °C

Operating humidity

0 % to 90 % (0 °C to 35 °C)

0 % to 70 % (35 °C to 55 °C)

Operating altitude

2000 m

Dimensions

11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2

Weight

0.23 kg (8 oz) includes batteries

Safety

IEC61010-1, IEC61010-2-030

Certification

CSA-CUS, CE

Warranty

One Year

Electromagnetic Compatibility (EMC)

IEC 61326-1

Portable EM environment; CISPR 11, Group 1, Class A

US (FCC)

47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103

Korea (KCC)

Class A Equipment (Industrial Broadcasting & Communication Equipment)

This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account