Fluke 3000 FC Wireless Multimeter

SKU
FLK-3000FC
Manufacturer:
Fluke
Fluke

Key Features:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V, Cat IV 600 V; IP54
Product Options:
Special Price $359.99 Regular Price $399.99

Secured and trusted checkout with

      The 3000 Wireless Multimeter is the captain of the Fluke wireless team. With the 3000 Wireless Multimeter, you see live measurements from multiple modules simultaneously and remotely on a single screen. The 3000 Wireless Multimeter displays the meter measurement, plus readings from up to 3 wireless modules, as far as 20 meters away. By seeing multiple readings at the same time, troubleshooters can see cause and effect, interactions between inputs/outputs or other measurement points, simultaneously and remotely. If more than three readings are required from more modules, add an optional PC adapter to your laptop for real time viewing of up to 10 modules.

AC Voltage
Range¹ / resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy2 3 445 Hz to 500 Hz1.0% + 3
500 Hz to 1 kHz2.0% + 3
1. AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mVRange / resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
ΩRange / resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
mA AC
(45 Hz to 1 kHz)
Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy1.5% + 3
mA DC2Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy10.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Overload protection1100 V RMS
Input impedance (nominal)< 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
< 0.7 V DC
< 0.9 V DC
Typical short circuit current< 350 mA
Overload protection1100 V RMS
Input impedance (nominal)< 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
2.000 V DC
Typical short circuit current< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions± 12 counts for changes > 350 mS in duration.
AC functions± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20m
Obstructed, sheetrock wallUp to 6.5m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326–1:2006, EN 61326–2–2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
Safety complianceANSI / ISA 61010–1 / (82.02.01): 3rd edition
CAN / CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010–1: 3rd edition
IEC / EN 61010–1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

Accessories

Fluke 3000 FC Wireless Multimeter

  • - True-RMS Wireless Multimeter
  • - TL175 Test Leads
  • - AC175 Alligator Clips

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series

As low as

Now $269.99

As low as

Now $829.99

As low as

Now $1,129.99

As low as

Now $1,459.99