DENT Instruments PowerScout 3 HD Power Submeter

SKU
PS3HD
Manufacturer:
DENT Instruments
DENT Instruments

Key Features:

  • 3 channels: 3-phase submeter monitors voltage, current, power, energy, and many other electrical parameters on single or three-phase systems
  • Two models available: DIN Rail Mount Enclosure or Wall Mount Enclosure 
  • Revenue grade. Third-party ANSI C12.20-2015 Class 0.2 certification (pending)
  • Continuous sampling: no blind cycles
  • Interval Data Recording: Store up to 63 days of 15-minute kWh data
  • Use with a full range of DENT Split Core or RōCoil™ Rogowski-style CTs, including several revenue-grade options
  • Line-Powered: 90-600V Phase-to-Phase Power Supply
  • 2-line LCD is standard on all configurations and shows real-time information about the meter configuration and metered data
  • Communicate using either BACnet or Modbus protocol
  • USB-C Connection is standard for configuration/meter troubleshooting
  • User-configurable alarm with isolated output
  • Data updates occur every 1.0 seconds
  • Patented PhaseChek™ technology confirms proper CT orientation
  • UL Listed, CE Mark, BTL Certification (pending)
  • 5-Year Warranty
  • *DENT Current Transformers sold Separately
Product Options:
$765.00

Secured and trusted checkout with

The New PowerScout 3 HD from Dent Instruments is the latest model in the HD family replacing the PowerScout 3037 as DENT Instruments’ 3-channel 3-phase meter. DENT's single-point meter boats features like increased measurement performance, industry-standard communications, and two form factors. It can utilize any of DENT’s internally-shunted, 333 mV output split-core or RōCoil CTs. Users can monitor a single three phase load or network with other PowerScout HD meters to monitor several loads across facilities.

 

The high speed continuous sampling enables data updates at a rate of 1 Hz and ANSI C12.20-2015 Class 0.2 revenue grade accuracy (depending on CT), the PowerScout 3 HD is ideal for accountability metering in commercial, retail, and industrial facilities including demand response and tenant submetering.

 

The PS3HD are line-powered with an internal wide-range power supply, allowing line-to-line voltages from 90-600 VAC. For convenience, the PS3HD also includes a USB (Type C) connector which allows the meter to be powered from a host PC or laptop computer during configuration.

 

The PowerScout 3 HD supports both Modbus (based on SunSpec IEEE-754) and BACnet communications protocols. Communications interface can be accomplished through serial RS-485 or Ethernet using either Modbus RTU, BACnet MS/TP, Modbus TCP, or BACnet IP protocols.

 

The PowerScout 3 HD can be quickly configured using one of two interfaces: ViewPoint HD PC Application or through a Web Browser. Configurations can be saved to a template for re-use. Use the on-board LCD and thumb wheel to verify setup.

 

The PowerScout 3 HD meter features DENT’s patented* PhaseChek™ circuitry for detecting mis-phased and backwards CTs. When used in conjunction with ViewPoint HD, advanced analytics are available including waveform visualization, vector polar plotting and harmonic distortion analysis.

 

The PS3HD is equipped with several safety features to ensure the protection of all users. Some of the features include:

  • • When the high-voltage (TouchSāf™) cover* is installed on the PowerScout HD meter, the NFPA70E-compliant USB interface is safe to use without the use of additional PPE or shutting off the electrical panel.
  • The 200 KAIC fuse that is standard on all PowerScout HD meters exceeds most regulatory requirements to make it the safest meter on the market.
  • The PowerScout HD meters have been evaluated to withstand 6kV line surges.

Always follow all local electrical codes and employer guidance regarding the use of PPE and other safety requirements.

* High-voltage (TouchSāf™) cover is standard on all PowerScout HD instruments except plate versions of the PowerScout 12 HD (PS12HD-P-D-N & PS12HD-P-N-N). Contact the factory for details.

 

The PowerScout Series meters are not meant to be standalone energy recorders. They are designed to connect as a slave device to a data logger, Remote Terminal Unit (RTU), or building management host network.

Technical
Service TypeSingle Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta)
PowerFrom L1 Phase to L2 Phase. 90-600VAC RMS CAT III 50/60 Hz, 500 mA AC Max
AC Protection0.5 A internal fuse protection. 200 KA interrupt.
Voltage Channels80-346 Volts AC Line-to-Neutral, 600 V Line-to-Line, CAT III.
Current Channels3 channels, 0.525 VAC max, 333 mV CTs, 0-4,000+ Amps depending on CT
Maximum Current Input150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A with RōCoil CTs
Measurement TypeTrue RMS using high-speed digital signal processing (DSP)
Line Frequency50/60 Hz
SamplingContinuous 1.8 kHz (no blind cycles)
Parameter Update Rate1.0 second
MeasurementsVolts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import (Received) kWh, Export (Delivered) kWh, Net kWh, Import (Received) kVAh, Export (Delivered) kVAh, Net kVAh, Import (Received) kVARh, Export (Delivered) kVARh, Net kVARh, THD, Theta, Frequency. All parameters for each phase and element total
Accuracy0.2% ANSI C12.20-2015 Class 0.2 (3rd party certification pending)
Resolution32-bit floating point
Display2 x 16 character display with tri-color backlight

 

Communications
HardwareRS-485 Serial and Ethernet
Max Communication Length1200 meters at 100K bits/second or less
Communication Rate (BAUD)Modbus: 9600, 19200, 38400, 57600, 76800, 115200 baud
BACnet: 9600, 19200, 38400, 76800
Data Bits8
ParityNone, Even, Odd
Stop Bit2, 1
Supported ProtocolsModbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP

 

Mechanical
Wire Connections12-28 AWG 600 VAC, Voltage connection must be #14 AWG or larger & 600 VAC rated
MountingWall mount enclosure or TS35/7.5 DIN Rail
Operating Temperature-20° to 60°C (-4° to 140°F)
Humidity5% to 95% non-condensing
EnclosureABS Plastic, 94-V0 flammability rating
Enclosure DimensionsDIN Rail Version
(L) 19.08cm x (W) 8.23cm x (H) 3.76cm (7.51” x 3.24” x 1.48”)
Wall Mount Version
(L) 25.70cm x (W) 14.00cm x (H) 5.37cm (10.12” x 5.50” x 2.12”)
Weight (Approximate)DIN Rail Version
363 g (13 ounces), exclusive of CTs.
Wall Mount Version
635 g (22 ounces), exclusive of CTs

 

Certifications
UL ListedConforms to UL Std 61010-1, 3rd Edition & IEC 61010-2-030 1st Edition
CELVD (EN61010-1), EMC (EN61326-1), RoHS 2 (EN50581)
ANSI C12.20 Class 0.2NIST Traceable Calibration (3rd party certification pending)

 

Viewpoint HD Software
Operating SystemWindows® 10, Windows® 8, Windows® 7
Communications10/100 Ethernet and USB 2.0
Web Page Security2 levels of PIN protection (Read/Write or Read-Only)
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • • Tenant Submetering (shopping malls, apartments, office space, etc)
  • • Bi-Directional Metering (renewable energy applications, such as solar or wind)
  • • Real-time power monitoring in commercial, retail, and industrial environments